Accuracy of the New ICD-9-CM Code for "Drip-and-Ship" Thrombolytic Treatment in Patients With Ischemic Stroke

被引:8
|
作者
Tonarelli, Silvina B. [1 ]
Tibbs, Michael [1 ]
Vazquez, Gabriela [1 ]
Lakshminarayan, Kamakshi [1 ]
Rodriguez, Gustavo J. [2 ]
Qureshi, Adnan I. [1 ]
机构
[1] Univ Minnesota, Med Ctr, Zeenat Qureshi Stroke Res Ctr, Minneapolis, MN 55455 USA
[2] Hennepin Cty Med Ctr, Minneapolis, MN 55415 USA
来源
关键词
ICD-9; code; ischemic stroke; V; 45.88; stroke; thrombolytics; drip and ship; rt-PA; PLASMINOGEN ACTIVATOR USE; AVAILABILITY; SERVICES;
D O I
10.1016/j.jstrokecerebrovasdis.2010.05.011
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
A new International Classification of Diseases, Ninth Revision, Clinical Modification (ICD-9-CM) diagnosis code, V45.88, was approved by the Centers for Medicare and Medicaid Services (CMS) on October 1, 2008. This code identifies patients in whom intravenous (IV) recombinant tissue plasminogen activator (rt-PA) is initiated in one hospital's emergency department, followed by transfer within 24 hours to a comprehensive stroke center, a paradigm commonly referred to as "drip-and-ship." This study assessed the use and accuracy of the new V45.88 code for identifying ischemic stroke patients who meet the criteria for drip-and-ship at 2 advanced certified primary stroke centers. Consecutive patients over a 12-month period were identified by primary ICD-9-CM diagnosis codes related to ischemic stroke. The accuracy of V45.88 code utilization using administrative data provided by Health Information Management Services was assessed through a comparison with data collected in prospective stroke registries maintained at each hospital by a trained abstractor. Out of a total of 428 patients discharged from both hospitals with a diagnosis of ischemic stroke, 37 patients were given ICD-9-CM code V45.88. The internally validated data from the prospective stroke database demonstrated that a total of 40 patients met the criteria for drip-and-ship. A concurrent comparison found that 92% (sensitivity) of the patients treated with drip-and-ship were coded with V45.88. None of the non-drip-and-ship stroke cases received the V45.88 code (100% specificity). The new ICD-9-CM code for drip-and-ship appears to have high specificity and sensitivity, allowing effective data collection by the CMS.
引用
收藏
页码:121 / 123
页数:3
相关论文
共 42 条
  • [1] Accuracy of the New ICD-9 Code for "Drip-and-ship" Thrombolytic Treatment in Patients With Acute Ischemic Stroke
    Tonarelli, Silvina B.
    Tibbs, Michael
    Vazquez, Gabriela
    Qureshi, M. N.
    Rodriguez, Gustavo J.
    Lakshminarayan, Kamakshi
    Qureshi, Adnan I.
    [J]. STROKE, 2010, 41 (04) : E308 - E308
  • [2] Accuracy of the New ICD-9 Code for "Drip-and-Ship" Thrombolytic Treatment in Patients with Acute Ischemic Stroke
    Tonarelli, Silvina B.
    Tibbs, Michael
    Qureshi, M. Naeem
    Rodriguez, Gustavo J.
    Lakshminarayan, Kamakshi
    Qureshi, Adnan I.
    Vazquez, Gabriela
    [J]. NEUROLOGY, 2010, 74 (09) : A515 - A515
  • [3] Accuracy of the New ICD-9 Code for "Drip-and-Ship" Thrombolytic Treatment in Patients with Ischemic Stroke. An Analysis of Minnesota Stroke Registry
    Tonarelli, Silvina
    Peacock, James H.
    Vazquez, Gabriela
    Tibbs, Michael
    Lakshminarayan, Kamakshi
    Tsai, Albert
    Qureshi, Adnan I.
    [J]. NEUROLOGY, 2011, 76 (09) : A146 - A146
  • [4] Drip-and-ship thrombolytic therapy for acute ischemic stroke
    Mizuno, S.
    Deguchi, I. D. Ichiro
    Kohyama, S.
    Tanahashi, N.
    Takao, M.
    [J]. JOURNAL OF THE NEUROLOGICAL SCIENCES, 2017, 381 : 624 - 624
  • [5] Drip-and-Ship Thrombolytic Therapy for Acute Ischemic Stroke
    Deguchi, Ichiro
    Mizuno, Satoko
    Kohyama, Shinya
    Tanahashi, Norio
    Takao, Masaki
    [J]. JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2018, 27 (01): : 61 - 67
  • [6] Accuracy of ICD-9-CM coding for acute ischemic stroke
    Goldstein, LB
    [J]. STROKE, 1998, 29 (01) : 321 - 321
  • [7] Drip-and-Ship Thrombolytic Treatment Paradigm Among Acute Ischemic Stroke Patients in the United States
    Tekle, Wondwossen G.
    Chaudhry, Saqib A.
    Hassan, Ameer E.
    Rodriguez, Gustavo J.
    Suri, M. Fareed K.
    Qureshi, Adnan I.
    [J]. STROKE, 2012, 43 (07) : 1971 - 1974
  • [8] Outcomes of thrombolytic therapy in acute ischemic stroke: mothership, drip-and-ship, and ship-and-drip paradigms
    Kijpaisalratana, Naruchorn
    Chutinet, Aurauma
    Akarathanawat, Wasan
    Vongvasinkul, Pakkawan
    Suwanwela, Nijasri C.
    [J]. BMC NEUROLOGY, 2020, 20 (01)
  • [9] Outcomes of thrombolytic therapy in acute ischemic stroke: mothership, drip-and-ship, and ship-and-drip paradigms
    Naruchorn Kijpaisalratana
    Aurauma Chutinet
    Wasan Akarathanawat
    Pakkawan Vongvasinkul
    Nijasri C. Suwanwela
    [J]. BMC Neurology, 20
  • [10] Accuracy of ICD-9-CM coding for the identification of patients with acute ischemic stroke - Effect of modifier codes
    Goldstein, LB
    [J]. STROKE, 1998, 29 (08) : 1602 - 1604