X-ray phase contrast microtomography for the analysis of the fibrous microstructure of SMC composites

被引:81
|
作者
Le, T. -H. [1 ]
Dumont, P. J. J. [2 ]
Orgeas, L. [1 ]
Favier, D. [1 ]
Salvo, L. [3 ]
Boller, E. [4 ]
机构
[1] INPG UJF, CNRS, Lab Sols Solides Struct 3S, F-38041 Grenoble 9, France
[2] CNRS INPG EFPG, LGP2, F-38042 St Martin Dheres 9, France
[3] CNRS IPG, Lab Genie Phys & Mecan Mat, F-38042 St Martin Dheres, France
[4] European Synchrotron Radiat Facil, ID Topog & Microtomog Grp 19, F-38043 Grenoble, France
关键词
polymer-matrix composites (PMCs); fibrous microstructure; porosity; X-ray microtomography; compression moulding;
D O I
10.1016/j.compositesa.2007.08.027
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
X-ray microtomographs of samples cut from non-deformed and compression moulded Sheet Moulding Compounds (SMC) plates have been analysed using the phase contrast mode. Results emphasise a significant decrease of the porosity after moulding, this phenomenon being enhanced with increasing the initial SMC temperature. They also show that pronounced migration of the polymer-matrix occurs through the thickness of the plates during compression moulding. The substructures of compression moulded plates through their thickness exhibit a core zone sandwiched between upper and lower skins. Inside the skins, the fibre content and the porosity are weaker than in core zones, and fibre-bundles are highly broken up. On the contrary, fibre-bundles remain preserved in core zones. Therein, the significant flattening and widening of bundles, their weak bending as well as their orientation have been quantified. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:91 / 103
页数:13
相关论文
共 50 条
  • [1] Microstructure reconstruction of fibrous C/C composites from X-ray microtomography
    Martin-Herrero, J.
    Germain, Ch.
    CARBON, 2007, 45 (06) : 1242 - 1253
  • [2] Design of X-ray interferometer for phase-contrast X-ray microtomography
    Momose, A
    Hirano, K
    X-RAY MICROSCOPY, PROCEEDINGS, 2000, 507 : 98 - 103
  • [3] The possibility of phase-contrast X-ray microtomography
    Momose, A
    Hirano, K
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 1999, 38 : 625 - 629
  • [4] X-ray phase-contrast microscopy and microtomography
    Mayo, SC
    Davis, TJ
    Gureyev, TE
    Miller, PR
    Paganin, D
    Pogany, A
    Stevenson, AW
    Wilkins, SW
    OPTICS EXPRESS, 2003, 11 (19): : 2289 - 2302
  • [5] Nondestructive imaging of hominoid dental microstructure using phase contrast X-ray synchrotron microtomography
    Tafforeau, Paul
    Smith, Tanya A.
    JOURNAL OF HUMAN EVOLUTION, 2008, 54 (02) : 272 - 278
  • [6] X-ray microtomography (μCT) using interferometric phase contrast
    Bonse, U
    Beckmann, F
    Biermann, T
    X-RAY MICROSCOPY, PROCEEDINGS, 2000, 507 : 69 - 75
  • [7] Phase-contrast X-ray microtomography of mouse fetus
    Hoshino, Masato
    Uesugi, Kentaro
    Yagi, Naoto
    BIOLOGY OPEN, 2012, 1 (03): : 269 - 274
  • [8] Aortic thrombi microstructure through contrast-enhanced X-ray microtomography
    Joris Léonet
    Jérôme Vicente
    Mariangela De Masi-Jacquier
    Valérie Deplano
    Scientific Reports, 15 (1)
  • [9] Single grating phase contrast imaging for x-ray microscopy and microtomography
    Bruyndonckx, P.
    Sasov, A.
    Pauwels, B.
    DEVELOPMENTS IN X-RAY TOMOGRAPHY IX, 2014, 9212
  • [10] Imaging renal structures by X-ray phase-contrast microtomography
    Wu, Jin
    Takeda, Tohoru
    Lwin, Thet Thet
    Momose, Atsushi
    Sunaguchi, Naoki
    Fukami, Tadanori
    Yuasa, Tetsuya
    Akatsuka, Takao
    KIDNEY INTERNATIONAL, 2009, 75 (09) : 945 - 951