Validation of RAPID'E-coli 2 for enumeration and differentiation of Escherichia coli and other coliform bacteria in selected foods -: Performance-tested methodSM 050601

被引:0
|
作者
Lauer, Wendy F.
Martinez, Frederic L.
Patel, Asmita
机构
[1] Bio-Rad Laboratories, 2000 Alfred Nobel Dr., Hercules, CA 94564, United States
[2] U.S. Food and Drug Administration, 5100 Paint Branch Pkwy., College Park, MD 20740, United States
[3] Richter International, 505 King Ave., Columbus, OH 43201, United States
[4] 19484 East Lakeshore Dr., Bigfork, MT 59911, United States
关键词
D O I
10.1093/jaoac/90.5.1284
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
RAPID'E. coli 2 agar (Bio-Rad Laboratories, Hercules, CA) is a chromogenic medium for differentiation and enumeration of E. coli and non-E. coli coliform bacteria in food. The principle of RAPID'E. coli 2 medium relies on simultaneous detection of 2 enzymatic activities, beta-D-glucuronidase (GLUC) and beta-D-galactosidase (GAL). Coliforms, other than E. coli (GAL+/GLUC-), form blue to green colonies, whereas, specifically, E. coli (GAL+/GLUC+) form Violet colonies. Eleven foods (raw ground beef, raw boneless pork, fermented sausage, processed ham, processed turkey, frozen turkey breast, raw ground chicken, cottage cheese, ricotta cheese, raw milk, and dry infant formula) were Validated, comparing the performance of RAPID'E. coli 2 agar to the reference method AOAC 966.24. Two sample incubation temperatures were evaluated, 37 and 44 degrees C, testing a mixture of naturally and artificially contaminated foods. If naturally contaminated food was not available, the matrix was artificially inoculated with one E. coli strain and one non-E. coli coliform strain. Method comparison studies demonstrated some statistical differences between the 2 methods, which are expected when a plating method is compared to a most probable number method. Inclusivity and exclusivity rates of the medium were 99 and 94%, respectively. The RAPID'E. coli 2 method was shown to be stable when minor variations were introduced.
引用
收藏
页码:1284 / 1315
页数:32
相关论文
共 10 条
  • [1] Matrix Extension Study: Validation of the Compact Dry EC Method for Enumeration of Escherichia coli and non-E. coli Coliform Bacteria in Selected Foods Modification to AOAC Performance Tested MethodSM 110402
    Mizuochi, Shingo
    Nelson, Maria
    [J]. JOURNAL OF AOAC INTERNATIONAL, 2016, 99 (02) : 451 - 460
  • [2] Performance validation of chromogenic coliform agar for the enumeration of Escherichia coli and coliform bacteria
    Lange, B.
    Strathmann, M.
    Ossmer, R.
    [J]. LETTERS IN APPLIED MICROBIOLOGY, 2013, 57 (06) : 547 - 553
  • [3] Matrix Extension Study: Validation of the Compact Dry CF Method for Enumeration of Total Coliform Bacteria in Selected Foods Modification to AOAC Performance Tested MethodSM 110401
    Mizuochi, Shingo
    Nelson, Maria
    [J]. JOURNAL OF AOAC INTERNATIONAL, 2016, 99 (02) : 444 - 450
  • [4] Validation of the AquaCHROM™ ECC for the Detection and Enumeration of Coliforms and Escherichia coli in Water Samples: AOAC Performance Tested MethodSM 072202
    Blackburn, Jonathan
    Deterding, Andrew
    Thompson, Wesley
    Benzinger Jr, M. Joseph
    Bastin, Benjamin
    Evrard, Julie
    Wentrup, Cecilia
    Michon, Christophe
    Ramos, Hugo Cruz
    [J]. JOURNAL OF AOAC INTERNATIONAL, 2023, 106 (03) : 678 - 689
  • [5] Validation of Modifications to the Soleris(R)E. coli Method for Detection and Threshold Determination of Escherichia coli in Select Foods: Level 3 Modification to AOAC Performance Tested MethodSM 101101
    Beck, Nancy
    Le, Quynh-Nhi
    Mozola, Mark
    Roman, Brooke
    Montei, Carolyn
    Zhang, Lei
    Biswas, Preetha
    Donofrio, Robert
    [J]. JOURNAL OF AOAC INTERNATIONAL, 2022, 105 (02) : 483 - 491
  • [6] Comparison of the Compact Dry EC with the most probable number method (AOAC official method 966.24) for enumeration of Escherichia coll and coliform bacteria in raw meats Performance-Tested MethodSM 110402
    Kodaka, Hidemasa
    Mizuochi, Sihngo
    Teramura, Hajime
    Nirazuka, Tadanobu
    [J]. Journal of AOAC International, 2006, 89 (01): : 100 - 114
  • [7] Comparison of the compact dry EC with the most probable number method (AOAC Official Method 966.24) for enumeration of Escherichia coli and coliform bacteria in raw meats -: Performance-tested methodsSM 110402
    Kodaka, H
    Mizuochi, S
    Teramura, H
    Nirazuka, T
    [J]. JOURNAL OF AOAC INTERNATIONAL, 2006, 89 (01) : 100 - 114
  • [8] Matrix Extension Study: Validation of the Compact Dry TC Method for Enumeration of Total Aerobic Bacteria in Selected Foods Modification to AOAC Performance Tested MethodSM 010404
    Mizuochi, Shingo
    Nelson, Maria
    [J]. JOURNAL OF AOAC INTERNATIONAL, 2016, 99 (02) : 461 - 468
  • [9] Validation of the KangarooSci® Aerobic Count Plate for the Enumeration of Meosphilic Aerobic Bacteria in Selected Foods and on Stainless Steel Environmental Surfaces: AOAC Performance Tested MethodSM 062301
    Wei, Danping
    Wu, Di
    Wang, Jisheng
    Li, Yazhou
    Sun, Xinyu
    Zhang, Can
    Zhang, Shuai
    Thompson, Wesley
    Benzinger, M. Joseph, Jr.
    Crowley, Erin
    [J]. JOURNAL OF AOAC INTERNATIONAL, 2023, 106 (06) : 1589 - 1597
  • [10] Validation of iQ-Check™ E. coli O157:H7 Real-Time PCR Test Kit for Detection of Escherichia coli O157:H7 in Selected Foods Performance-Tested MethodsSM 020801
    Lauer, Wendy F.
    Tymciu, Sylvie
    Sidi, Caroline D.
    Sonigo, Pierre