Non-Contact Heart Sound Measurement Using Independent Component Analysis

被引:1
|
作者
Muramatsu, Shun [1 ]
Yamamoto, Michitaka [1 ]
Takamatsu, Seiichi [1 ]
Itoh, Toshihiro [1 ]
机构
[1] Univ Tokyo, Grad Sch Engn, Dept Precis Engn, Tokyo 1138656, Japan
关键词
Heart; Signal to noise ratio; Frequency measurement; Noise measurement; Electrocardiography; Band-pass filters; Data mining; Microphone arrays; Heart sound; non-contact measurement; microphone array; independent component analysis; signal averaging; LUNG;
D O I
10.1109/ACCESS.2022.3206467
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
A non-contact heart sound measurement method using independent component analysis (ICA) was successfully developed, and the measured heart sound was quantitatively evaluated with the signal-to-noise ratio (SNR). There have been recent developments in the automated diagnosis of cardiovascular diseases based on the measurement of heart sounds. However, measuring heart sounds require physical restraint. Here, we propose a non-invasive and non-constrained method for non-contact measurement of heart sounds using microphones. We successfully demonstrated this method by applying ICA to multi-channel measured sounds with a microphone array. Then, we quantitatively evaluated it by measuring "pseudo heart sounds" at a distance of up to 200 mm from the source using four microphones in an anechoic chamber and a conference room. SNR was improved by increasing the number of microphones. This method could measure pseudo heart sounds even in the presence of artificial noise created by heating, ventilation, and air conditioning systems and human voices. We suggested that measurable distance can be improved by using more microphones. Moreover, we successfully measured actual heart sounds at a distance of 160 mm from the chest wall. This non-contact heart sound measurement method provided valuable information about the heart, such as visual recognition of the first (S1) and the second (S2) heart sounds.
引用
收藏
页码:98625 / 98632
页数:8
相关论文
共 50 条
  • [1] Non-contact measurement of sound speed of tissues
    Hachiya, H
    Ohtsuki, S
    ULTRASONIC TISSUE CHARACTERIZATION, 1996, : 63 - 72
  • [2] Heart Sound Separation Using Fast Independent Component Analysis
    Tong, Zichun
    Qader, Ikhlas Abdel
    Abu-Amara, Fadi
    PROCEEDINGS 2015 INTERNATIONAL CONFERENCE ON DEVELOPMENTS IN ESYSTEMS ENGINEERING DESE 2015, 2015, : 3 - 6
  • [3] A Direct Phase-Tracking Doppler Radar Using Wavelet Independent Component Analysis for Non-Contact Respiratory and Heart Rate Monitoring
    Mercuri, Marco
    Liu, Yao-Hong
    Lorato, Ilde
    Torfs, Tom
    Wieringa, Fokko
    Bourdoux, Andre
    Van Hoof, Chris
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2018, 12 (03) : 632 - 643
  • [4] Non-Contact Heart Rate Measurement Using Ghost Imaging System
    Yu, Jianming
    He, Yuchen
    Li, Bin
    Chen, Hui
    Zheng, Huaibin
    Liu, Jianbin
    Zhou, Lifan
    Niu, Yi
    Wu, Haodong
    Xu, Zhuo
    JOURNAL OF BIOPHOTONICS, 2025, 18 (04)
  • [5] Non-contact measurement of the heart rate and the heart rate variability
    Kranjec, Jure
    Begus, Samo
    Gersak, Gregor
    Drnovsek, Janko
    ELEKTROTEHNISKI VESTNIK, 2013, 80 (03): : 135 - 140
  • [7] Non-contact Measurement of the Heart Rate by a Image Sensor
    Bernacchia, Natascia
    Marchionni, Paolo
    Ercoli, Ilaria
    Scalise, Lorenzo
    SENSORS, 2015, 319 : 371 - 375
  • [8] Non-contact Methods for Heart Rate Measurement: A Review
    Kaur, Gaganjot
    Kilby, Jeff
    2021 INTERNATIONAL CONFERENCE ON COMPUTING SCIENCES (ICCS 2021), 2021, : 289 - 294
  • [9] Study on Non-contact Heart Beat Measurement Method by Using Depth Sensor
    Aoki, Hirooki
    Suzuki, Atsushi
    Shiga, Tsuyoshi
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 1, 2019, 68 (01): : 341 - 345
  • [10] WLAN Rx Sensitivity Analysis by Using Non-Contact Probing Measurement
    Lin, Albert
    Chen, Noah
    Liao, Ming-Wen
    Liu, Yu-Cheng
    2017 12TH INTERNATIONAL MICROSYSTEMS, PACKAGING, ASSEMBLY AND CIRCUITS TECHNOLOGY CONFERENCE (IMPACT), 2017, : 250 - 253