Beamlet dose distribution compression and reconstruction using wavelets for intensity modulated treatment planning

被引:13
|
作者
Zakarian, C [1 ]
Deasy, JO [1 ]
机构
[1] Washington Univ, Med Ctr, Dept Radiat Oncol, Alvin J Siteman Canc Ctr,Mallinckrodt Inst Radiol, St Louis, MO 63110 USA
关键词
treatment planning; wavelets; beamlets; intensity modulated radiation therapy;
D O I
10.1118/1.1636560
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Intensity modulated radiation therapy (IMRT) treatment planning is often formulated as the optimization of weights of fixed-geometry subfields (beamlets). Efficient optimization techniques can be based on direct storage of the influence matrix relating beamlet weights to dose values. However, direct storage of beamlet dose distributions for IMRT treatment planning can easily exceed several gigabytes, and is therefore often not feasible. We present a method for rapidly calculating full three-dimensional IMRT dose distributions, based on a vector of beamlet weights. The method is based on compressed beamlet dose distributions using fast digital wavelet transforms and so-called hard thresholding. We studied the method with a rectangular beamlet of 0.5 cm X 0.5 cm cross section from a monoenergetic 6 MeV photon point source simulated in homogeneous (water) and heterogeneous (CT-data) phantoms. Dose was calculated using the accurate VMC + + Monte Carlo engine. The beamlet dose distributions were wavelet transformed and compressed by dropping wavelet coefficients below a given threshold value. Dose is then computed using the remaining wavelets. Selection of the wavelet basis function, decomposition level, and threshold values, for different slice orientations (transverse or parallel to the beam) and varying angles of beamlet incidence are studied. A typical in-slice compression ratio for a plane containing a beamlet was 32:1 using the sym2 wavelet and a threshold of 0.01, with a typical root-mean-square error, for voxels above 50% of the maximum dose, of about 0.04%. The overall compression performance, which includes many planes with little information content, is on the order of 100: 1 or greater compared to full matrix storage. Although other methods are available to make the use of stored influence matrix values more feasible in IMRT treatment planning (such as using coarse grids or restricting values to defined volumes of interest) we conclude that wavelet compression facilitates the storage and use of full pencil dose deposition (influence matrix) data in IMRT treatment planning. (C) 2004 American Association of Physicists in Medicine.
引用
收藏
页码:368 / 375
页数:8
相关论文
共 50 条
  • [1] Wavelet compression of beamlet dose distributions for IMRT treatment planning
    Zakarian, C
    Deasy, J
    [J]. MEDICAL PHYSICS, 2002, 29 (06) : 1335 - 1335
  • [2] A Method of Verifying Intensity Modulated Radiation Therapy Through Beamlet Weight Verification and Dose Reconstruction
    Yeo, I. J.
    Kim, J.
    Wang, B.
    Chew, M.
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 1797 - +
  • [3] OAR Dose Distribution Prediction and gEUD Based Automatic Treatment Planning Optimization for Intensity Modulated Radiotherapy
    Jia, Qiyuan
    Li, Yongbao
    Wu, Aiqian
    Guo, Futong
    Qi, Mengke
    Mai, Yanhua
    Kong, Fantu
    Zhen, Xin
    Zhou, Linghong
    Song, Ting
    [J]. IEEE ACCESS, 2019, 7 : 141426 - 141437
  • [4] Fast and Generalized Dose Reconstruction Method Using Virtual Beamlet Dose Responses
    Yeo, I.
    Jung, J.
    Kim, J.
    [J]. MEDICAL PHYSICS, 2010, 37 (06) : 3228 - +
  • [5] Comparison of the Dose Distribution Obtained from Dosimetric Systems with Intensity Modulated Radiotherapy Planning System in the Treatment of Prostate Cancer
    Gokce, M.
    Uslu, D. Kocyigit
    Ertunc, C.
    Karali, T.
    [J]. 9TH INTERNATIONAL PHYSICS CONFERENCE OF THE BALKAN PHYSICAL UNION (BPU-9), 2016, 1722
  • [6] Dose planning of intensity modulated radiotherapy for nasopharyngeal cancer using compensating filters
    Chu, SS
    Suh, CO
    [J]. PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 2081 - 2081
  • [7] Dose-distance constraints: A new method for controlling intensity modulated treatment planning dose distributions
    Deasy, J
    Zakarian, C
    [J]. MEDICAL PHYSICS, 2003, 30 (06) : 1334 - 1334
  • [8] Underestimation of low-dose radiation in treatment planning of intensity-modulated radiotherapy
    Jang, Si Young
    Liu, H. Helen
    Mohan, Radhe
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 71 (05): : 1537 - 1546
  • [9] Incremental dose calculation optimization of inverse treatment planning for intensity modulated radiation therapy
    Nash, RV
    Carol, MP
    Huber, RE
    Campbell, RC
    [J]. PROCEEDINGS OF THE XIITH INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY, 1997, : 431 - 433
  • [10] The generalized equivalent uniform dose function as a basis for intensity-modulated treatment planning
    Choi, B
    Deasy, J
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (20): : 3579 - 3589