Evaluation of Parathyroid Lesions With Point Shear Wave Elastography

被引:18
|
作者
Hattapoglu, Salih [1 ]
Goya, Cemil [1 ]
Hamidi, Cihad [1 ]
Tasdemir, Bekir [1 ,2 ]
Alan, Bircan
Durmaz, Mehmet Sedat [3 ]
Teke, Memik [1 ]
Ekici, Faysal [1 ]
机构
[1] Dicle Univ, Sch Med, Dept Radiol, TR-21280 Diyarbakir, Turkey
[2] Dicle Univ, Dept Nucl Med, Diyarbakir, Turkey
[3] Diyarbakir Obstet & Pediat Hosp, Dept Radiol, Diyarbakir, Turkey
关键词
head and neck ultrasound; parathyroid adenoma; shear wave velocity; Virtual Touch tissue; FORCE IMPULSE ELASTOGRAPHY; PRIMARY HYPERPARATHYROIDISM; DIFFERENTIAL-DIAGNOSIS; THYROID-NODULES; RADIATION; ULTRASONOGRAPHY; BENIGN; ARFI;
D O I
10.7863/ultra.15.10074
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives-The aim of our study was to evaluate the shear wave velocity (SWV) of parathyroid lesions by point shear wave elastography (SWE) and to compare their stiffness with that of thyroid nodules and normal thyroid parenchyma quantitatively. Methods-Thirty-six patients considered to have parathyroid disorders by clinical and laboratory tests and scintigraphy were enrolled in the study between January 2012 and February 2015. Conventional sonography, Doppler sonography, and the Virtual Touch tissue quantification (VTQ) method of point SWE (Siemens Medical Solutions, Mountain View, CA) were conducted with a linear transducer (4-9 MHz) while the patients were in the supine position. Then we compared our VTQ measurements with pathologic results. Results-The 36 patients included 31 female and 5 male patients with a mean age +/- SD of 49 +/- 15.7 years (range, 15-79 years). The mean SWV of parathyroid hyperplasia lesions (n = 4) was 1.46 +/- 0.23 m/s, whereas the mean SWV of parathyroid adenomas (n = 32) was 2.28 +/- 0.50 m/s. The mean SWV of normal thyroid parenchyma (n = 36) was 1.62 +/- 0.20 m/s, and the mean SWV of benign thyroid nodules (n = 21) was 2.25 +/- 0.51 m/s. A significant difference was found between SWV values of normal thyroid parenchyma and parathyroid adenoma (P<.001). A cutoff value of 1.73 m/s for adenomas led to 90.0% sensitivity and 80.6% specificity. Conclusions-The VTQ method of point SWE may contribute to the discrimination of parathyroid adenomas from the thyroid gland. However, more comprehensive studies are needed.
引用
收藏
页码:2179 / 2182
页数:4
相关论文
共 50 条
  • [1] 2D-Shear Wave Elastography in the Evaluation of Parathyroid Lesions in Patients with Hyperparathyroidism\
    Golu, Ioana
    Sporea, Ioan
    Moleriu, Lavinia
    Tudor, Anca
    Cornianu, Marioara
    Vlad, Adrian
    Timar, Romulus
    Balas, Melania
    Amzar, Daniela
    Vlad, Mihaela
    [J]. INTERNATIONAL JOURNAL OF ENDOCRINOLOGY, 2017, 2017
  • [2] Comparison of point shear wave elastography and transient elastography in the evaluation of patients with NAFLD
    Giulio Argalia
    Claudio Ventura
    Niccolò Tosi
    Daniele Campioni
    Corrado Tagliati
    Marianna Tufillaro
    Monica Cucco
    Gianluca Svegliati Baroni
    Andrea Giovagnoni
    [J]. La radiologia medica, 2022, 127 : 571 - 576
  • [3] Comparison of point shear wave elastography and transient elastography in the evaluation of patients with NAFLD
    Argalia, Giulio
    Ventura, Claudio
    Tosi, Niccolo
    Campioni, Daniele
    Tagliati, Corrado
    Tufillaro, Marianna
    Cucco, Monica
    Baroni, Gianluca Svegliati
    Giovagnoni, Andrea
    [J]. RADIOLOGIA MEDICA, 2022, 127 (05): : 571 - 576
  • [4] Utility of point shear wave elastography in characterisation of focal liver lesions
    Allah, Maha Hasab
    Salama, Rabab Maamoun
    Marie, Mohamad Saeed
    Mandur, Ahmed Alsaeed
    Omar, Heba
    [J]. EXPERT REVIEW OF GASTROENTEROLOGY & HEPATOLOGY, 2018, 12 (02) : 201 - 207
  • [5] The diagnostic value of shear wave elastography for parathyroid lesions and comparison with cervical lymph nodes
    Polat, Ahmet Veysel
    Ozturk, Mesut
    Akyuz, Behic
    Celenk, Cetin
    Kefeli, Mehmet
    Polat, Cafer
    [J]. MEDICAL ULTRASONOGRAPHY, 2017, 19 (04) : 386 - 391
  • [6] Shear Wave Elastography versus Strain Elastography in Diagnosing Parathyroid Adenomas
    Cotoi, Laura
    Amzar, Daniela
    Sporea, Ioan
    Borlea, Andreea
    Navolan, Dan
    Varcus, Fiore
    Stoian, Dana
    [J]. INTERNATIONAL JOURNAL OF ENDOCRINOLOGY, 2020, 2020
  • [7] Multisample Ultrasound Point Shear Wave Elastography of the Liver Repeatability and Agreement With Conventional Point Shear Wave Elastography
    Dillman, Jonathan R.
    Trout, Andrew T.
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 2023, 42 (12) : 2749 - 2756
  • [8] Evaluation of ultrasound point shear wave elastography reliability in an elasticity phantom
    Sultan, Salahaden R.
    Alghamdi, Amer
    Abdeen, Rawan
    Almutairi, Fahad
    [J]. ULTRASONOGRAPHY, 2022, 41 (02) : 291 - 297
  • [9] Evaluation of Different Types of Breast Lesions With Apparent Diffusion Coefficient and Shear Wave Elastography Values: Comparison of Shear Wave Elastography and Apparent Diffusion Coefficient in Breast Lesions
    Aybar, M. Devran
    Turna, Onder
    [J]. JOURNAL OF DIAGNOSTIC MEDICAL SONOGRAPHY, 2022, 38 (05) : 420 - 428
  • [10] Evaluation of Multiparametric Shear Wave Elastography Indices in Malignant and Benign Breast Lesions
    Sanli, Deniz Esin Tekcan
    Yildirim, Duzgun
    Kandemirli, Sedat Giray
    Sanli, Ahmet Necati
    Aribal, Erkin
    [J]. ACADEMIC RADIOLOGY, 2022, 29 : S50 - S61