Evaluation of in-hospital electrocardiography versus 24-hour Holter for rate control in dogs with atrial fibrillation

被引:18
|
作者
Gelzer, A. R. [1 ]
Kraus, M. S. [1 ]
Rishniw, M. [2 ]
机构
[1] Univ Liverpool, Sch Vet Sci, Small Anim Teaching Hosp, Dept Cardiol, Leahurst CH64 7TE, Neston, England
[2] Cornell Univ, Coll Vet Med, Dept Biomed Sci, Ithaca, NY 14853 USA
关键词
DILATED CARDIOMYOPATHY; AGREEMENT; SURVIVAL;
D O I
10.1111/jsap.12363
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
ObjectivesTo determine if the in-clinic ECG-derived heart rate could predict the at-home Holter-derived 24-hour average heart rate (Holter(24h)), and whether it is useful to identify slow versus fast atrial fibrillation in dogs. Materials and Methods82 pairs of 1-minute ECGs and 24-hour Holter recordings were acquired in 34 dogs with atrial fibrillation. The initial 24-hour Holter was used to test if the ECG heart rate can identify dogs with slow versus fast atrial fibrillation based on a Holter(24h) threshold value of 140bpm. ResultsECG heart rate overestimated Holter(24h) by 26bpm (95% CI: 3bpm, 48bpm; P<0015) with a 95% limit of agreement of -21 to 83bpm. The in-clinic ECG-derived heart rate A155 bpm had a sensitivity of 73% and a specificity of 100% for identifying a Holter(24h) HR A140 bpm; an in-clinic ECG-derived HR <160bpm had a sensitivity and specificity of 91% each. Clinical SignificanceIn-clinic ECG assessment of heart rate in dogs with atrial fibrillation does not reliably predict the heart rate in their home environment. However, an in-clinic heart rate greater than 155bpm is useful in identifying fast atrial fibrillation, allowing clinicians to stratify which case may benefit from antiarrhythmic therapy.
引用
收藏
页码:456 / 462
页数:7
相关论文
共 50 条
  • [1] IN-HOSPITAL ELECTROCARDIOGRAPH VERSUS 24-HOUR HOLTER MONITOR FOR ASSESSING HEART RATE IN DOGS WITH ATRIAL FIBRILLATION
    Calland, L. M.
    Green, H. W., III
    Van De Wiele, C. M.
    Sederquist, K.
    [J]. JOURNAL OF VETERINARY INTERNAL MEDICINE, 2010, 24 (03) : 733 - 733
  • [2] Evaluation of heart rate variability using 24-hour Holter electrocardiography in hypertensive patients
    Julario, Rerdin
    Mulia, Eka Prasetya Budi
    Rachmi, Dita Aulia
    A'yun, Maya Qurota
    Septianda, Imanita
    Dewi, Ivana Purnama
    Juwita, Rahima Ratna
    Dharmadjati, Budi Baktijasa
    [J]. JOURNAL OF ARRHYTHMIA, 2021, 37 (01) : 157 - 164
  • [3] Prevalence of atrial fibrillation on a 24-hour Holter in adult Indians
    Rao, M. Srinivasa
    Mullasari, Ajit
    Hiremath, Jagdish S.
    Sengottuvelu, G.
    Jaiswal, Aparna
    Jhala, Darshan
    Makkar, Jitendra Singh
    Kalmath, B. C.
    Benjamin, Bino
    Dharmadhikari, Annirudha
    Tanna, Mihir
    Khan, Aziz
    Jain, Siddhant
    Sambasivam, K. A.
    Purnanand, A.
    Raju, N. S. Rama
    Sarkar, Goutam
    Prajapati, Hiren
    Verberk, Willem J.
    [J]. INDIAN HEART JOURNAL, 2024, 76 (03) : 218 - 220
  • [4] Continuous Stroke Unit Electrocardiographic Monitoring Versus 24-Hour Holter Electrocardiography for Detection of Paroxysmal Atrial Fibrillation After Stroke
    Rizos, Timolaos
    Guentner, Janina
    Jenetzky, Ekkehart
    Marquardt, Lars
    Reichardt, Christine
    Becker, Ruediger
    Reinhardt, Roland
    Hepp, Thomas
    Kirchhof, Paulus
    Aleynichenko, Elena
    Ringleb, Peter
    Hacke, Werner
    Veltkamp, Roland
    [J]. STROKE, 2012, 43 (10) : 2689 - +
  • [5] Comparison of heart rate obtained from shorter duration Holter recordings to 24-hour mean heart rate in dogs with atrial fibrillation
    Gunasekaran, Tamilselvam
    Olivier, Bari
    Griffith, Lucas
    Sanders, Robert
    [J]. PLOS ONE, 2020, 15 (11):
  • [6] 24-HOUR AMBULATORY ELECTROCARDIOGRAPHY IN PATIENTS WITH CHRONIC ATRIAL-FIBRILLATION
    PITCHER, D
    PAPOUCHADO, M
    JAMES, MA
    REES, JR
    [J]. BRITISH MEDICAL JOURNAL, 1986, 292 (6520): : 594 - 594
  • [7] Atrial Fibrillation Detection During 24-Hour Ambulatory Blood Pressure Monitoring: Comparison With 24-Hour Electrocardiography
    Kollias, Anastasios
    Destounis, Antonios
    Kalogeropoulos, Petros
    Kyriakoulis, Konstantinos G.
    Ntineri, Angeliki
    Stergiou, George S.
    [J]. HYPERTENSION, 2018, 72 (01) : 110 - 115
  • [8] Seasonal variation in paroxysmal atrial fibrillation documented by 24-hour Holter electrocardiogram
    Watanabe, Eiichi
    Kuno, Yukiko
    Takasuga, Hirohisa
    Tong, MaoQing
    Sobue, Yoshihiro
    Uchiyama, Tatsushi
    Kodama, Itsuo
    Hishida, Hitoshi
    [J]. HEART RHYTHM, 2007, 4 (01) : 27 - 31
  • [9] Diagnostic yield of repeat 24-hour holter electrocardiography for detection of paroxysmal atrial fibrillation in patients with embolic stroke of undetermined source
    Liantinioti, C.
    Tympas, K.
    Chondrogianni, M.
    Zompola, C.
    Roussopoulou, A.
    Katsanos, A. H.
    Safouris, A.
    Voumvourakis, K.
    Parissis, J.
    Tsivgoulis, G.
    [J]. INTERNATIONAL JOURNAL OF STROKE, 2015, 10 : 270 - 270
  • [10] Comparison of in-hospital versus 24-hour ambulatory electrocardiography for detection of ventricular premature complexes in mature Boxers
    Meurs, KM
    Spier, AW
    Wright, NA
    Hamlin, RL
    [J]. JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 2001, 218 (02) : 222 - 224