Comparison of Magnetic Resonance Imaging of Aortic Valve Stenosis and Aortic Root to Multimodality Imaging for Selection of Transcatheter Aortic Valve Implantation Candidates

被引:37
|
作者
Paelinck, Bernard P. [1 ]
Van Herck, Paul L. [1 ]
Rodrigus, Inez [2 ]
Claeys, Marc J. [1 ]
Laborde, Jean-Claude [4 ]
Parizel, Paul M. [3 ]
Vrints, Christiaan J. [1 ]
Bosmans, Johan M. [1 ]
机构
[1] Univ Antwerp Hosp, Dept Cardiol, Antwerp, Belgium
[2] Univ Antwerp Hosp, Dept Cardiac Surg, Antwerp, Belgium
[3] Univ Antwerp Hosp, Dept Radiol, Antwerp, Belgium
[4] Royal Brompton Hosp, London SW3 6LY, England
来源
AMERICAN JOURNAL OF CARDIOLOGY | 2011年 / 108卷 / 01期
关键词
TRANSESOPHAGEAL ECHOCARDIOGRAPHY; COMPUTED-TOMOGRAPHY; AREA; DIMENSIONS; COMPLEX;
D O I
10.1016/j.amjcard.2011.02.348
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of the present study was to compare the aortic valve area, aortic valve annulus, and aortic root dimensions measured using magnetic resonance imaging (MRI) with catheterization, transthoracic echocardiography (TTE), and transesophageal echocardiography (TEE). An optimal prosthesis aortic root match is an essential goal when evaluating patients for transcatheter aortic valve implantation. Comparisons between MRI and the other imaging techniques are rare and need validation. In 24 consecutive, high-risk, symptomatic patients with severe aortic stenosis, aortic valve area was prospectively determined using MRI and direct planimetry using three-dimensional TTE and calculated by catheterization using the Gorlin equation and by Doppler echocardiography using the continuity equation. Aortic valve annulus and the aortic root dimensions were prospectively measured using MRI, 2-dimensional TTE, and invasive aortography. In addition, aortic valve annulus was measured using TEE. No differences in aortic valve area were found among MRI, Doppler echocardiography, and 3-dimensional TTE compared with catheterization (p = NS). Invasive angiography underestimated aortic valve annulus compared with MRI (p < 0.001), TEE (p < 0.001), and 2-dimensional TTE (p < 0.001). Two-dimensional TTE tended to underestimate the aortic valve annulus diameters compared to TEE and MRI. In contrast to 2-dimensional TTE, 3 patients had aortic valve annulus beyond the transcatheter aortic valve implantation range using TEE and MRI. In conclusion, MRI planimetry, Doppler, and 3-dimensional TTE provided an accurate estimate of the aortic valve area compared to catheterization. MRI and TEE provided similar and essential assessment of the aortic valve annulus dimensions, especially at the limits of the transcatheter aortic valve implantation range. (C) 2011 Elsevier Inc. All rights reserved. (Am J Cardiol 2011;108:92-98)
引用
收藏
页码:92 / 98
页数:7
相关论文
共 50 条
  • [1] Imaging aortic root and aortic valve stenosis in percutaneous aortic valve implantation candidates
    Bernard P Paelinck
    Delphine Petillot
    Inez Rodrigus
    Christiaan J Vrints
    Johan M Bosmans
    Journal of Cardiovascular Magnetic Resonance, 12 (Suppl 1)
  • [2] Imaging aortic root and aortic valve stenosis in percutaneous aortic valve implantation candidates
    Paelinck, B. P.
    Petillot, D.
    Vrints, C. J.
    Bosmans, J. M.
    EUROPEAN HEART JOURNAL, 2009, 30 : 938 - 938
  • [3] Aortic Root Imaging in the Era of Transcatheter Aortic Valve Implantation/Transcatheter Aortic Valve Replacement
    Escobedo, Carlos
    Schoenhagen, Paul
    REVISTA ESPANOLA DE CARDIOLOGIA, 2013, 66 (11): : 839 - 841
  • [4] Multimodality imaging throughout transcatheter aortic valve implantation
    de Heer, Linda M.
    Kluin, Jolanda
    Stella, Pieter R.
    Sieswerda, Gertjan T. J.
    Mali, Willem P. Th M.
    van Herwerden, Lex A.
    Budde, Ricardo P. J.
    FUTURE CARDIOLOGY, 2012, 8 (03) : 413 - 424
  • [5] Selection of percutaneous aortic valve replacement candidates: echocardiographic assessment of aortic stenosis and aortic root morphology in comparison with cardiac catheterization and magnetic resonance imaging
    Paelinck, Bernard
    Petillot, Delphine
    Vrints, Christiaan
    Bosmans, Johan
    ACTA CARDIOLOGICA, 2009, 64 (01) : 130 - 130
  • [6] Multimodality Quantitative Imaging of Aortic Root for Transcatheter Aortic Valve Implantation More Complex Than It Appears
    Tuzcu, E. Murat
    Kapadia, Samir R.
    Schoenhagen, Paul
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (03) : 195 - 197
  • [7] Holographic imaging during transcatheter aortic valve implantation procedure in bicuspid aortic valve stenosis
    Rymuza, Bartosz
    Grodecki, Kajetan
    Kaminski, Jakub
    Scislo, Piotr
    Huczek, Zenon
    KARDIOLOGIA POLSKA, 2017, 75 (10) : 1056 - 1056
  • [8] Multimodality Imaging in Transcatheter Aortic Valve Replacement
    Smith, Thomas W.
    Bommer, William J.
    REVIEWS IN CARDIOVASCULAR MEDICINE, 2014, 15 (02) : 75 - 85
  • [9] Transcatheter aortic valve implantation in unicuspid aortic valve stenosis
    Chopra, Aashish
    Uthayakumaran, Kalaichelvan
    Rao, Ravinder Singh
    Mullasari, Ajit Sankardas
    EUROINTERVENTION, 2020, 15 (18) : E1592 - E1593
  • [10] Transcatheter aortic valve implantation in bicuspid aortic valve stenosis
    Perlman, Gidon Y.
    Blanke, Philipp
    Webb, John G.
    EUROINTERVENTION, 2016, 12 : Y42 - Y45