Mathematical modeling and cascade design of hollow fiber membrane contactor for CO2 absorption by monoethanolamine

被引:57
|
作者
Boributh, Somnuk [1 ]
Rongwong, Wichitpan [1 ]
Assabumrungrat, Suttichai [2 ]
Laosiripojana, Navadol [3 ]
Jiraratananon, Ratana [1 ]
机构
[1] King Mongkuts Univ Technol Thonburi, Dept Chem Engn, Bangkok 10140, Thailand
[2] Chulalongkorn Univ, Dept Chem Engn, Fac Engn, Bangkok 10330, Thailand
[3] King Mongkuts Univ Technol Thonburi, Joint Grad Sch Energy & Environm, Bangkok 10140, Thailand
关键词
Carbon dioxide; Cascade design; Membrane contactor; Membrane wetting; MASS-TRANSFER; CARBON-DIOXIDE; GAS; RESISTANCE; REMOVAL;
D O I
10.1016/j.memsci.2012.01.048
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The absorption of CO2 from the gas mixture (CO2-CH4) by polyvinylidenefluoride (PVDF) hollow fiber membrane contactor using monoethanolamine (MEA) as the absorbent was performed. The mathematical model has been developed to predict the absorption performance. The model is validated with the experimental results for estimating the wetting ratio (x*) as the function of liquid velocity and MEA concentration. The suitable hollow fiber membrane module with effective fiber length of 50 cm is selected for the design of multistage membrane contactors. The absorption flux of multistage membrane contactor is simulated based on the value of x* obtained from the experiments. The three-stage cascade design is selected to compare the system performance with different gas and liquid flow patterns. The results of the simulation show that the individual gas flow (G-ID) gives higher performance compared to the gas flow in series (G-IS) for all operating conditions studied. The three different flow patterns of liquid including (i) liquid flow in series (L-IS), (ii) liquid flow in series with splitting (L-ISS) and (iii) liquid flow in series with recycle (L-ISR) are compared. At low MEA concentration (0.25 M), the L-ISR can improve the system performance at low liquid velocities, while L-ISS shows the highest performance at high liquid velocities. For the system with high MEA concentration (1.0 M), L-ISR can improve the performance at low to moderate liquid velocities, whereas L-ISS does not improve the system performance at any liquid velocity. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:175 / 189
页数:15
相关论文
共 50 条
  • [1] Rate based modeling for CO2 absorption using monoethanolamine solution in a hollow fiber membrane contactor
    Rongwong, Wichitpan
    Assabumrungrat, Suttichai
    Jiraratananon, Ratana
    [J]. JOURNAL OF MEMBRANE SCIENCE, 2013, 429 : 396 - 408
  • [2] Modeling and experimental study of CO2 absorption in a hollow fiber membrane contactor
    Zhang, Hong-Yan
    Wang, Rong
    Liang, David Tee
    Tay, Joo Hwa
    [J]. JOURNAL OF MEMBRANE SCIENCE, 2006, 279 (1-2) : 301 - 310
  • [3] Modeling and simulation of the hollow fiber bore size on the CO2 absorption in membrane contactor
    Ghasem, Nayef
    [J]. CHEMICAL PRODUCT AND PROCESS MODELING, 2020, 15 (04):
  • [4] Experimental Study of CO2 Absorption in a Hollow Fiber Membrane Contactor
    Kallas, Therese
    Chabanon, Elodie
    Germain, Guillaume
    Bouallou, Chakib
    [J]. PRES'09: 12TH INTERNATIONAL CONFERENCE ON PROCESS INTEGRATION, MODELLING AND OPTIMISATION FOR ENERGY SAVING AND POLLUTION REDUCTION, PTS 1 AND 2, 2009, 18 : 267 - 272
  • [5] Modeling of CO2 Stripping in a Hollow Fiber Membrane Contactor for CO2 Capture
    Wang, Zhen
    Fang, Mengxiang
    Yu, Hai
    Ma, Qinhui
    Luo, Zhongyang
    [J]. ENERGY & FUELS, 2013, 27 (11) : 6887 - 6898
  • [6] Experimental studies on CO2 absorption in immersed hollow fiber membrane contactor
    Wu, Xiaona
    Wang, Liang
    Zhang, Zhaohui
    Li, Wenyang
    Guo, Xingfei
    [J]. SUSTAINABLE CITIES DEVELOPMENT AND ENVIRONMENT, PTS 1-3, 2012, 209-211 : 1571 - 1575
  • [7] CO2 absorption at elevated pressures using a hollow fiber membrane contactor
    Dindore, VY
    Brilman, DWF
    Feron, PHM
    Versteeg, GF
    [J]. JOURNAL OF MEMBRANE SCIENCE, 2004, 235 (1-2) : 99 - 109
  • [8] Development of asymmetric polysulfone hollow fiber membrane contactor for CO2 absorption
    Rahbari-Sisakht, M.
    Ismail, A. F.
    Matsuura, T.
    [J]. SEPARATION AND PURIFICATION TECHNOLOGY, 2012, 86 : 215 - 220
  • [9] Experimental and Modeling Study of Trace CO2 Removal in a Hollow-Fiber Membrane Contactor, Using CO2-Loaded Monoethanolamine
    Wang, Zhen
    Fang, Mengxiang
    Yu, Hai
    Wei, Chiao-Chien
    Luo, Zhongyang
    [J]. INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2013, 52 (50) : 18059 - 18070
  • [10] A modeling study on the effects of membrane characteristics and operating parameters on physical absorption of CO2 by hollow fiber membrane contactor
    Boributh, Somnuk
    Assabumrungrat, Suttichai
    Laosiripojana, Navadol
    Jiraratananon, Ratana
    [J]. JOURNAL OF MEMBRANE SCIENCE, 2011, 380 (1-2) : 21 - 33