Thermal Endurance of Cables by Connecting of Distributed Generation Objects to the Electric Power System

被引:0
|
作者
Borvanov, Stepan [1 ]
Asainov, Danil [1 ]
机构
[1] Natl Res Univ, MPEI, Dept Elect Stat, Krasnokasarmennaya 17, Moscow 111250, Russia
关键词
electromagnetic and electromechanical transients; short circuit currents;
D O I
暂无
中图分类号
G40 [教育学];
学科分类号
040101 ; 120403 ;
摘要
By projecting of electrical annex of power plants not only the choice of the main electrical installations is conducted (e.g. generators, transformers, circuit-breakers), but also of cable lines. By checking of generator stator circuit cables for thermal endurance the thermal effect time is the short circuit clearance time by the operation of the main protective equipment and the current is the short circuit current from the electric power system or the generator. The goal of this paper is to adjust the cable choice method in a stator circuit of a low-power generator inbuilt in the existing nodes of the electrical power system as a distributed generation object. By thermal endurance check of stator circuit installations for such generators the short circuit reference point may be on the adjoined segment of the electrical grid. In this case, by electrically close short circuits and after their clearance without disconnection of the generator from the power grid an additional current rush and asynchronous operation current will increase the thermal generation. Recommendations for refinement of cable thermal endurance check method were developed for a gas turbine low-power generator, which operates parallel to the electric power system.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] A review on distributed generation impacts on electric power system
    Ufa, R. A.
    Malkova, Y. Y.
    Rudnik, V. E.
    Andreev, M., V
    Borisov, V. A.
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2022, 47 (47) : 20347 - 20361
  • [2] Characteristics of distributed generation system and related research issues caused by connecting it to power system
    Kang, Longyun
    Guo, Hongxia
    Wu, Jie
    Chen, Sizhe
    Dianwang Jishu/Power System Technology, 2010, 34 (11): : 43 - 47
  • [3] Challenges to Implementing Distributed Generation in Area Electric Power System
    Lai, L. L.
    Chan, S. W.
    Lee, P. K.
    Lai, C. S.
    2011 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN, AND CYBERNETICS (SMC), 2011, : 797 - 801
  • [4] The Impact of Connecting Distributed Generation to the Distribution System
    Mgaya, E. V.
    Muller, Z.
    ACTA POLYTECHNICA, 2007, 47 (4-5) : 96 - 101
  • [5] Characteristic Analysis of DC Electric Railway Systems with Superconducting Power Cables Connecting Power Substations
    Ohsaki, H.
    Matsushita, N.
    Koseki, T.
    Tomita, M.
    11TH EUROPEAN CONFERENCE ON APPLIED SUPERCONDUCTIVITY (EUCAS2013), PTS 1-4, 2014, 507
  • [6] Low-cost distributed solar-thermal-electric power generation
    Der Minassians, AD
    Aschenbach, KH
    Sanders, SR
    NONIMAGING OPTICS: MAXIMUM EFFICIENCY LIGHT TRANSFER VII, 2003, 5185 : 89 - 98
  • [7] A study of electric power quality using storage system in distributed generation
    Yukita, Kazuto
    Goto, Yasuyuki
    Ichiyanagi, Katsuhiro
    Hirose, Kenichi
    PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON ELECTRICAL POWER QUALITY AND UTILISATION, VOLS 1 AND 2, 2007, : 602 - +
  • [8] Analysis of the effect of distributed generation on life expectancy of power cables
    Agah, S. M. Mousavi
    Abyaneh, H. Askarian
    Siano, P.
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2014, 24 (05): : 698 - 712
  • [9] Probabilistic assessment of the impact of connecting a new distributed generation unit to a potentially congested power system
    Sun, J.
    Labeau, P. E.
    Vergnol, A.
    SAFETY AND RELIABILITY - SAFE SOCIETIES IN A CHANGING WORLD, 2018, : 2153 - 2160
  • [10] Electric Power Quality and Distributed Generation in Cuba
    Francisco Fernandez, Marielys
    Diaz Fuentes, Raul
    Castro Fernandez, Miguel
    Costa Montiel, Angel
    REVISTA CUBANA DE INGENIERIA, 2010, 1 (03): : 41 - 50