Introducing an automated high content confocal imaging approach for Organs-on-Chips

被引:64
|
作者
Peel, Samantha [1 ]
Corrigan, Adam M. [1 ]
Ehrhardt, Beate [1 ,5 ]
Jang, Kyung-Jin [2 ]
Caetano-Pinto, Pedro [3 ]
Boeckeler, Matthew [4 ]
Rubins, Jonathan E. [2 ]
Kodella, Konstantia [2 ]
Petropolis, Debora B. [2 ]
Ronxhi, Janey [2 ]
Kulkarni, Gauri [2 ]
Foster, Alison J. [3 ]
Williams, Dominic [3 ]
Hamilton, Geraldine A. [2 ]
Ewart, Lorna [3 ]
机构
[1] AstraZeneca, IMED Biotech Unit, Discovery Sci, Cambridge, England
[2] Emulate Inc, Boston, MA USA
[3] AstraZeneca, IMED Biotech Unit, Drug Safety & Metab, Cambridge, England
[4] AstraZeneca, IMED Biotech Unit, Discovery Sci, Boston, MA USA
[5] Univ Bath, Inst Math Innovat, Bath, Avon, England
关键词
DRUG; BENZBROMARONE; MODELS;
D O I
10.1039/c8lc00829a
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Organ-Chips are micro-engineered systems that aim to recapitulate the organ microenvironment. Implementation of Organ-Chips within the pharmaceutical industry aims to improve the probability of success of drugs reaching late stage clinical trial by generating models for drug discovery that are of human origin and have disease relevance. We are adopting the use of Organ-Chips for enhancing pre-clinical efficacy and toxicity evaluation and prediction. Whilst capturing cellular phenotype via imaging in response to drug exposure is a useful readout in these models, application has been limited due to difficulties in imaging the chips at scale. Here we created an end-to-end, automated workflow to capture and analyse confocal images ofmulticellularOrgan-Chips to assess detailed cellular phenotype across large batches of chips. By automating this process, we not only reduced acquisition time, but we also minimised process variability and user bias. This enabled us to establish, for the first time, a framework of statistical best practice for Organ-Chip imaging, creating the capability of using Organ-Chips and imaging for routine testing in drug discovery applications that rely on quantitative image data for decisionmaking. We tested our approach using benzbromarone, whosemechanism of toxicity has been linked tomitochondrial damage with subsequent induction of apoptosis and necrosis, and staurosporine, a tool inducer of apoptosis. We also applied this workflow to assess the hepatotoxic effect of an active AstraZeneca drug candidate illustrating its applicability in drug safety assessment beyond testing tool compounds. Finally, we have demonstrated that this approach could be adapted to Organ-Chips of different shapes and sizes through application to a Kidney-Chip.
引用
收藏
页码:410 / 421
页数:12
相关论文
共 50 条
  • [1] Development of a PET System Capable of Imaging Organs-on-Chips
    Birindelli, G.
    Pizzichemi, M.
    Pagano, F.
    Kruithof-De Julio, M.
    Ziegler, S.
    Rominger, A.
    Auffray, E.
    Shi, K.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (SUPPL 1) : S78 - S79
  • [2] Dynamic Imaging of Organs-on-Chips using a Dedicated PET Scanner: A Simulation Study
    Clement, Christoph
    Birindelli, Gabriele
    Pizzichemi, Marco
    Pagano, Fiammetta
    Kruithof-De Julio, Marianna
    Ziegler, Sibylle
    Rominger, Axel
    Qiu, Huang
    Auffray, Etiennette
    Shi, Kuangyu
    JOURNAL OF NUCLEAR MEDICINE, 2023, 64
  • [3] Multisensor-integrated organs-on-chips platform for automated and continual in situ monitoring of organoid behaviors
    Zhang, Yu Shrike
    Aleman, Julio
    Shin, Su Ryon
    Kilic, Tugba
    Kim, Duckjin
    Shaegh, Seyed Ali Mousavi
    Massa, Solange
    Riahi, Reza
    Chae, Sukyoung
    Hu, Ning
    Avci, Huseyin
    Zhang, Weijia
    Silvestri, Antonia
    Nezhad, Amir Sanati
    Manbohi, Ahmad
    De Ferrari, Fabio
    Polini, Alessandro
    Calzone, Giovanni
    Shaikh, Noor
    Alerasool, Parissa
    Budina, Erica
    Kang, Jian
    Bhise, Nupura
    Ribas, Joao
    Pourmand, Adel
    Skardal, Aleksander
    Shupe, Thomas
    Bishop, Colin E.
    Dokmeci, Mehmet Remzi
    Atala, Anthony
    Khademhosseini, Ali
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2017, 114 (12) : E2293 - E2302
  • [4] The Synergy between Deep Learning and Organs-on-Chips for High-Throughput Drug Screening: A Review
    Dai, Manna
    Xiao, Gao
    Shao, Ming
    Zhang, Yu Shrike
    BIOSENSORS-BASEL, 2023, 13 (03):
  • [5] Automated high content imaging for in vitro assessment of nanomaterial toxicity
    Harris, Georgina
    Palosaari, Taina
    Mennecozzi, Milena
    Gineste, Jean-Michele
    Liska, Roman
    Saavedra, Luis
    Milcamps, Anne
    Whelan, Maurice
    TOXICOLOGY LETTERS, 2012, 211 : S41 - S41
  • [6] High speed unsupervised fluorescence lifetime imaging confocal multiwell plate reader for high content analysis
    Talbot, Clifford B.
    McGinty, James
    Grant, David M.
    McGhee, Ewan J.
    Owen, Dylan M.
    Zhang, Wei
    Bunney, Tom D.
    Munro, Ian
    Isherwood, Beverly
    Eagle, Rob
    Hargreaves, Andre
    Katan, Matilda
    Dunsby, Chris
    Neil, Mark A. A.
    French, Paul M. W.
    JOURNAL OF BIOPHOTONICS, 2008, 1 (06) : 514 - 521
  • [7] Automated video-mosaicking approach for confocal microscopic imaging in vivo: an approach to address challenges in imaging living tissue and extend field of view
    Kose, Kivanc
    Gou, Mengran
    Yelamos, Oriol
    Cordova, Miguel
    Rossi, Anthony M.
    Nehal, Kishwer S.
    Flores, Eileen S.
    Camps, Octavia
    Dy, Jennifer G.
    Brooks, Dana H.
    Rajadhyaksha, Milind
    SCIENTIFIC REPORTS, 2017, 7
  • [8] Automated video-mosaicking approach for confocal microscopic imaging in vivo: an approach to address challenges in imaging living tissue and extend field of view
    Kivanc Kose
    Mengran Gou
    Oriol Yélamos
    Miguel Cordova
    Anthony M. Rossi
    Kishwer S. Nehal
    Eileen S. Flores
    Octavia Camps
    Jennifer G. Dy
    Dana H. Brooks
    Milind Rajadhyaksha
    Scientific Reports, 7
  • [9] Standardized mounting method of (zebrafish) embryos using a 3D-printed stamp for high-content, semi-automated confocal imaging
    David Simon Kleinhans
    Virginie Lecaudey
    BMC Biotechnology, 19
  • [10] Standardized mounting method of (zebrafish) embryos using a 3D-printed stamp for high-content, semi-automated confocal imaging
    Kleinhans, David Simon
    Lecaudey, Virginie
    BMC BIOTECHNOLOGY, 2019, 19 (01)