Does the examiner's experience matter in evaluation of the kinematics of the upper limb?

被引:4
|
作者
Magalhaes Goncalves, Diogo Henrique [1 ]
Politti, Fabiano [1 ]
Bley, Andre Serra [1 ]
Garbelotti, Silvio Antonio, Jr. [2 ]
de Godoy, Wagner [3 ]
Garcia Lucareli, Paulo Roberto [1 ]
机构
[1] Univ Nove Julho UNINOVE, Human Mot Anal Lab, Rehabil Sci Dept, Sao Paulo, SP, Brazil
[2] Univ Fed Sao Paulo, Dept Morphol & Genet, Sao Paulo, Brazil
[3] Albert Einstein Hosp, Movement Anal Lab, Sao Paulo, Brazil
关键词
Reliability; Shoulder; Scapula; Kinematics; Upper limb; MOTION ANALYSIS; RELIABILITY; SHOULDER; REPEATABILITY; ELEVATION; ACCURACY; MOVEMENT; VALIDITY; ANTERIOR;
D O I
10.1016/j.jbiomech.2018.12.035
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This study aimed to evaluate test and retest reliability according to examiner experience with the three-dimensional kinematics of the trunk, scapula, and arm segments during flexion and unilateral abduction of the arm. Ten men and 10 women (mean age, 25.1 [1.1] years) participated in this study. Each volunteer participated in six test sessions, four on the first day (two for each examiner) and two on the second day (one for each examiner). A 48-h interval was given between test days. The assessments were made by one examiner with movement analysis experience and a second examiner without experience. For each session (intra-day), the volunteers performed five repetitions of unilateral arm flexions and abductions using their dominant arms. After 1 h, the data were re-collected and all markers were replaced. Data from the trunk, scapula, and arm were analysed at 30 degrees, 60 degrees, 90 degrees, and 120 degrees of arm flexion and abduction using intraclass coefficient correlation, standard error of the measurement, and analysis of variance. The results did not differ between the experienced and inexperienced examiners except for trunk axial rotation at all studied angles and for arm rotation at 120 of abduction. The examiner previously trained in movement analysis marker placement demonstrated the same intra-tester reliability as the inexperienced tester when marker placement accuracy was the variable of interest. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:257 / 262
页数:6
相关论文
共 50 条
  • [1] Evaluation of the kinematics of the shoulder and of the upper limb
    Roux, E
    Bouilland, S
    Bouttens, D
    Istas, D
    Godillon-Maquinghen, AP
    Lepoutre, FX
    [J]. PROCEEDINGS OF THE THIRD CONFERENCE OF THE INTERNATIONAL SHOULDER GROUP, 2001, : 66 - 71
  • [2] Evaluation of wheelchair user's upper limb kinematics during throwing activities: a preliminary study
    Louis, N.
    Gorce, P.
    [J]. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2013, 16 : 116 - 117
  • [3] Evaluation of the global optimisation method within the upper limb kinematics analysis
    Roux, E
    Bouilland, S
    Godillon-Maquinghen, AP
    Bouttens, D
    [J]. JOURNAL OF BIOMECHANICS, 2002, 35 (09) : 1279 - 1283
  • [4] Evaluation of initialization procedures for estimating upper limb kinematics with MARG sensors
    Galinski, Daniel
    Dehez, Bruno
    [J]. 2012 4TH IEEE RAS & EMBS INTERNATIONAL CONFERENCE ON BIOMEDICAL ROBOTICS AND BIOMECHATRONICS (BIOROB), 2012, : 1801 - 1806
  • [5] Novel kinematics indexes for the upper limb reaching movements evaluation with robotic exoskeleton.
    Iuppariello, Luigi
    Faiella, Giuliana
    Macias, P.
    Cesarelli, Mario
    Nespoli, M.
    Clemente, Fabrizio
    [J]. 2020 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2020,
  • [7] DOES PHYSICAL EXAMINATION ASSIST IN THE EVALUATION OF DISORDERS OF THE NECK AND UPPER LIMB?
    Reading, I. C.
    Walker-Bone, K. E.
    Palmer, K. T.
    Coggon, D.
    Cooper, C.
    [J]. RHEUMATOLOGY, 2003, 42 : 15 - 16
  • [8] Predicting the Cause of Upper Gastrointestinal Hemorrhage: Does Clinical Experience Matter?
    de Melo, Silvio W.
    Guerrero, Richard
    Bhore, Rafia
    Rockey, Don C.
    [J]. GASTROENTEROLOGY, 2009, 136 (05) : A637 - A637
  • [9] Experimental protocol for the kinematics measurement of the shoulder and of the upper limb
    Roux, E
    Bouilland, S
    Bouttens, D
    Istas, D
    Godillon-Maquinghen, AP
    Lepoutre, FX
    [J]. ARCHIVES OF PHYSIOLOGY AND BIOCHEMISTRY, 2000, 108 (1-2) : 66 - 66
  • [10] Multivariate analysis of the kinematics of an upper limb rehabilitation robot
    Sobiech, Mariusz
    Michnik, Andrzej
    Chuchnowska, Iwona
    Karpiel, Ilona
    Wolanski, Wojciech
    [J]. ACTA OF BIOENGINEERING AND BIOMECHANICS, 2024, 26 (01) : 55 - 66