Raman Laser Spectrometer optical head: qualification model assembly and integration verification.

被引:1
|
作者
Ramos, G. [1 ]
Sanz-Palomino, M. [1 ]
Moral, A. G. [1 ]
Canora, C. P. [1 ]
Belenguer, T. [1 ]
Canchal, R. [1 ]
Prieto, J. A. R. [2 ]
Santiago, A. [2 ]
Gordillo, C. [2 ]
Escribano, D. [1 ]
Lopez-Reyes, G. [3 ]
Rull, F. [3 ]
机构
[1] INTA, Ctra Ajalvir Km 4, Torrejon De Ardoz 28850, Spain
[2] Ingn Sistemas Def Espana SA, INTA, ISDEFE, C Beatriz de Bobadilla 3, Madrid 28040, Spain
[3] Univ Valladolid, Ctr Astrobiol, Av Francisco Valles,8,Parque Tecnol Boecillo, E-47151 Valladolid, Spain
关键词
Raman spectroscopy; Mars; AIV;
D O I
10.1117/12.2277003
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Raman Laser Spectrometer (RLS) is the Pasteur Payload instrument of the ExoMars mission, within the ESA's Aurora Exploration Programme, that will perform for the first time in an out planetary mission Raman spectroscopy. RLS is composed by SPU (Spectrometer Unit), iOH (Internal Optical Head), and ICEU (Instrument Control and Excitation Unit). iOH focuses the excitation laser on the samples (excitation path), and collects the Raman emission from the sample (collection path, composed on collimation system and filtering system). Its original design presented a high laser trace reaching to the detector, and although a certain level of laser trace was required for calibration purposes, the high level degrades the Signal to Noise Ratio confounding some Raman peaks. So, after the bread board campaign, some light design modifications were implemented in order to fix the desired amount of laser trace, and after the fabrication and the commitment of the commercial elements, the assembly and integration verification process was carried out. A brief description of the iOH design update for the engineering and qualification model (iOH EQM) as well as the assembly process are briefly described in this papers. In addition, the integration verification and the first functional tests, carried out with the RLS calibration target (CT), results are reported on.
引用
收藏
页数:9
相关论文
共 25 条
  • [1] Raman Laser Spectrometer optical head: flight model performance verification
    Santiago, A.
    Ramos, G.
    Sanz-Palomino, M.
    Gordillo, C.
    Cabrero, J.
    Moral, A. G.
    Prieto, J. A. R.
    Canora, C. P.
    Belenguer, T.
    Canchal, R.
    Gallego, P.
    Escribano, D.
    Lopez-Reyes, G.
    Rull, F.
    [J]. SPACE TELESCOPES AND INSTRUMENTATION 2018: OPTICAL, INFRARED, AND MILLIMETER WAVE, 2018, 10698
  • [2] Raman Laser Spectrometer Flight Model Assembly and Integration Verification: end to end functional tests for thermal strap assembly procedure re-definition
    Rodriguez-Prieto, J.
    Ramos, G.
    Moral, A. G.
    Canora, C. P.
    Rull, F.
    Belenguer, T.
    Quintana, C.
    Zafra, J.
    Cabrero, J.
    Santiago, A.
    Escribano, D.
    [J]. UV/OPTICAL/IR SPACE TELESCOPES AND INSTRUMENTS: INNOVATIVE TECHNOLOGIES AND CONCEPTS IX, 2019, 11115
  • [3] RLS iOH: ExoMars Raman laser spectrometer optical head bread board to flight model design and performance evolutions
    Ramos, Gonzalo
    Sanz-Palomino, Miguel
    Moral, Andoni G.
    Perez, Carlos
    Belenguer, Tomas
    Canchal, Rosario
    Prieto, Jose A. R.
    Santiago, Amaia
    Gordillo, Cecilia
    Escribano, David
    Lopez-Reyes, Guillermo
    Rull, Fernando
    [J]. JOURNAL OF RAMAN SPECTROSCOPY, 2020, 51 (09) : 1761 - 1770
  • [4] Optical Verification Tests of the NISP/Euclid Grism Qualification Model
    Caillat, Amandine
    Costille, Anne
    Pascal, Sandrine
    Vives, Sebastien
    Rossin, Christelle
    Sanchez, Patrice
    Foulon, Benjamin
    [J]. SPACE TELESCOPES AND INSTRUMENTATION 2016: OPTICAL, INFRARED, AND MILLIMETER WAVE, 2016, 9904
  • [5] Assembly and characterization of an optical fiber probe for use in a portable Raman spectrometer
    de Lima, Carlos Jose
    Silveira Jr, Landulfo
    Rosa, Vitor da Silva
    Lucindo, Murilo Antunes Alves
    Pacheco, Marcos Tadeu Tavares
    [J]. INSTRUMENTATION SCIENCE & TECHNOLOGY, 2024,
  • [6] NEW SLITLESS OPTICAL-FIBER LASER RAMAN SPECTROMETER
    WALRAFEN, GE
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1974, 64 (10) : 1368 - 1368
  • [7] NEW SLITLESS OPTICAL FIBER LASER-RAMAN SPECTROMETER
    WALRAFEN, GE
    [J]. APPLIED SPECTROSCOPY, 1975, 29 (02) : 179 - 185
  • [8] RAMAN spectrometer: development of SPU FM based on enhanced qualification model for Exomars 2020
    Fco. Cabrero, J.
    Fernandez, M.
    Colombo, M.
    Escribano, D.
    Gallego, P.
    Canchal, R.
    Belenguer, T.
    Garcia-Martinez, J.
    Encinas, J. M.
    Bastide, L.
    Hutchinson, I.
    Moral, A.
    Canora, C. P.
    Prieto, J. A. R.
    Gordillo, C.
    Santiago, A.
    Berrocal, A.
    Rull, F.
    [J]. INTERNATIONAL CONFERENCE ON SPACE OPTICS-ICSO 2018, 2018, 11180
  • [9] OPTICAL PROPERTIES BEHAVIOR OF THREE OPTICAL FILTERS AND A MIRROR USED IN THE INTERNAL OPTICAL HEAD OF A RAMAN LASER SPECTROMETER AFTER EXPOSED TO PROTON RADIATION
    Guembe, V.
    Alvarado, C. G.
    Fernandez-Rodriguez, M.
    Gallego, P.
    Belenguer, T.
    Diaz, E.
    [J]. INTERNATIONAL CONFERENCE ON SPACE OPTICS-ICSO 2014, 2014, 10563
  • [10] Integration, Alignment and Verification of Optical System Assembly for FORMOSAT-5
    Chen, Ching-Wei
    Huang, Po-Hsuan
    Chen, Chia-Ray
    Chan, Chia-Yen
    Lien, Chun-Chieh
    Huang, Po-Han
    Hsu, Ming-Ying
    Chang, Shenci-Tsong
    Huang, Ting-Ming
    [J]. OPTICAL SYSTEM ALIGNMENT, TOLERANCING, AND VERIFICATION VIII, 2014, 9195