Criticality in the fabrication of ion extraction system for SST-1 neutral beam injector

被引:5
|
作者
Jana, M. R. [1 ]
Mattoo, S. K. [1 ]
机构
[1] Inst Plasma Res, Gandhinagar 382428, Gujarat, India
关键词
SST-1; neutral beam injector; positive ion source; extraction system; measurements of grid dimensions;
D O I
10.1016/j.fusengdes.2008.02.001
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
For the heating of plasma in steady-state superconducting tokamak (SST-1) (Y.C. Saxena, SST-1 Team, Present status of the SST-1 project, Nucl. Fusion 40 (2000) 1069-1082; D. Bora, SST-1 Team, Test results on systems developed for the SST-1 tokamak, Nucl. Fusion 43 (2003) 1748-1758), a neutral beam injector is provided to raise the ion temperature to similar to 1 keV. This injector has a capability of injecting hydrogen beam with the power of 0.5 MW at 30 keV. For the upgrade of SST-1, power of 1.7 MW at 55 KeV is required. Further, beam power is to be provided for a pulse length of 1000S. We have designed a neutral beam injector (S.K. Mattoo, A.K. Chakraborty, U.K. Baruah, P.K. Jayakumar, M. Bandyopadhyay, N. Bisai, Ch. Chakrapani, M.R. Jana, R. Onali, V. Prahlad, P.J. Patel, G.B. Patel, B. Prajapati, N.V.M. Rao, S. Rambabu, C. Rotti, S.K. Sharma, S. Shah, V. Sharma, M.J. Singh, Engineering design of the steady-state neutral beam injector for SST-1, Fusion Eng. Des. 56 (2001) 685-691; A.K. Chakraborty, N. Bisai, M.R. Jana, P.K. Jayakumar, U.K. Baruah, P.J. Patel, K. Rajasekar, S.K. Mattoo, Neutral beam injector for steady-state superconducting tokamak, Fusion Technol. (1996) 657-660; P.K. Jayakumar, M.R. Jana, N. Bisai, M. Bajpai, N.P Singh, U.K. Baruah, A.K. Chakraborty, M. Bandyopadhyay, C. Chrakrapani, D. Patel, G.B. Patel, P. Patel, V. Prahlad, N.V.M. Rao, C. Rotti, V. Sreedhar, S.K. Mattoo, Engineering issues of a 1000S neutral beam ion source, Fusion Technol. 1 (1998) 419-422) satisfying the requirements for both SST-1 and its upgrade. Since intense power is to be transported to SST-1 situated at a distance of several meters from the ion source, the optical quality of the beam becomes a primary concern. This in turn, is determined by the uniformity of the ion source plasma and the extractor geometry. To obtain the desired optical quality of the beam, stringent tolerances are to be met during the fabrication of ion extractor system. SST-1 neutral beam injector is based on positive ion source. The extraction system consists of three grids, each having extraction area of (width) 230 mm x (height) 480 mm and 774-shaped apertures of 8-mm diameter. To obtain horizontal focal length of 5.4 m and vertical of 7 m, each grid consists of two halves with 387 apertures. Two halves are inclined at an angle of 1.07+/-0.01 degrees. For long pulse operation, active water cooling is provided by in-laid down of dense network of 22 wavy semicircular (r= 1.1+/-0.05 mm) cooling channels in the space available between the apertures. The required flatness of the copper plate is 100 mu m and positioning tolerance of aperture is +/-60 mu m. The measurement obtained after fabrication is compared with the specifications. It is pointed out that fabrication within set tolerance limit could be achieved only through process of fabrication and high-resolution measurements. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:649 / 654
页数:6
相关论文
共 50 条
  • [1] Ion deflection system for SST-1 neutral beam injector
    Singh, MJ
    Chakraborty, AK
    Bandyopadhyay, M
    Bisai, N
    Baruah, UK
    Jana, MR
    Jayakumar, PK
    Patel, PJ
    Patel, D
    Patel, G
    Prahlad, V
    Rao, MV
    Mattoo, SK
    [J]. 17TH IEEE/NPSS SYMPOSIUM ON FUSION ENGINEERING, VOLS 1 AND 2, 1998, : 1087 - 1090
  • [2] Performance Test Results of Ion Beam Transport for SST-1 Neutral Beam Injector
    Jana, M. R.
    Mattoo, S. K.
    Uhlemann, R.
    [J]. 23RD NATIONAL SYMPOSIUM ON PLASMA SCIENCE AND TECHNOLOGY (PLASMA-2008), 2010, 208
  • [3] Design of an ion extractor system for a prototype ion source experiment for SST-1 neutral beam injector
    Jana, M. R.
    Bandyopadhaya, M.
    Singh, N. P.
    Sharma, S. K.
    Chakraborty, A. K.
    Baruah, U. K.
    Mattoo, S. K.
    [J]. FUSION ENGINEERING AND DESIGN, 2010, 85 (01) : 122 - 125
  • [4] Engineering design of the steady state neutral beam injector for SST-1
    Mattoo, SK
    Chakraborty, AK
    Baruah, UK
    Jayakumar, PK
    Bandyopadhyay, M
    Bisai, N
    Chakrapani, C
    Jana, MR
    Onali, R
    Prahlad, V
    Patel, PJ
    Patel, GB
    Prajapati, B
    Rao, NVM
    Rambabu, S
    Rotti, C
    Sharma, SK
    Shah, S
    Sharma, V
    Singh, MJ
    Singh, NP
    Sridhar, B
    [J]. FUSION ENGINEERING AND DESIGN, 2001, 56-57 : 685 - 691
  • [5] Long pulse characteristics of 5 MW ion source for SST-1 neutral beam injector
    Jana, M. R.
    Mattoo, S. K.
    Chakraborty, A. K.
    Baruah, U. K.
    Patel, G. B.
    Jayakumar, P. K.
    [J]. FUSION ENGINEERING AND DESIGN, 2008, 83 (5-6) : 729 - 735
  • [6] Compact beam line design for the SST-1 NB injector
    Chakraborty, AK
    Bandyopadhyay, M
    Jayakumar, PK
    Bisai, N
    Singh, MJ
    Baruah, UK
    Jana, MR
    Patel, PJ
    Patel, D
    Patel, G
    Prahlad, V
    Rao, MV
    Mattoo, SK
    [J]. 17TH IEEE/NPSS SYMPOSIUM ON FUSION ENGINEERING, VOLS 1 AND 2, 1998, : 1083 - 1086
  • [7] Steady state performance test analysis of actively cooled extractor grids for SST-1 neutral beam injector
    Jana, M. R.
    Mattoo, S. K.
    Khan, M.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (11):
  • [8] Noise Mitigation in Thermocouple Signal Conditioning System for Neutral Beam Calorimeter for NBI SST-1
    Bansal, Laxmi Kant
    Patel, Paresh J.
    Qureshi, Karishma
    Patel, Vishnu B.
    Gupta, Laxmi N.
    Thakkar, Dipal P.
    Sumod, C. B.
    Vadher, Vijay
    Parmar, Sanjay L.
    Bharathi, Punyapu
    Vattipalle, Prahlad
    Baruah, Ujjwal K.
    [J]. IEEE TRANSACTIONS ON PLASMA SCIENCE, 2014, 42 (06) : 1780 - 1784
  • [9] Neutral transport baffling studies for SST-1
    Jaishankar, S
    Warrier, M
    Deshpande, SP
    [J]. FUSION ENGINEERING AND DESIGN, 2002, 60 (02) : 167 - 178
  • [10] Preliminary Results of Ion Beam Extraction Tests on EAST Neutral Beam Injector
    胡纯栋
    [J]. Plasma Science and Technology., 2012, 14 (10) - 873