Fast analysis of PAH by GC and GC/MS using isomer specific GC capillary columns

被引:3
|
作者
Britten, Allen J. [1 ]
Naikwadi, Krishnat P. [2 ]
机构
[1] Cape Breton Univ, Dept Chem, Sydney, NS B1P 6L2, Canada
[2] J & K Sci, Milton, ON, Canada
关键词
fast GC; isomer specific separation; polycyclic aromatic hydrocarbons; microbore column;
D O I
10.1080/10406630802142805
中图分类号
O62 [有机化学];
学科分类号
070303 ; 081704 ;
摘要
The required separation of polycyclic aromatic hydrocarbons (PAH) by GC, to meet regulatory requirements, depends largely on column selectivity. Liquid crystal (LC) capillary columns are highly selective for PAH separation. In the current investigation analysis and separation of PAH on columns coated with only the LC stationary phase, the combination of LC and non-polar stationary phase and only non-polar stationary phase, have been studied. The complete separation of isomeric PAH in the mixture of 16 priority PAH is achieved on the LC column. The inherent advantage of higher efficiency for microbore columns compared to conventional 0.25 mm internal diameter (ID) columns of the same length, in combination with the selectivity of the LC stationary phase, resulted in the fast analysis of 16 PAH on the columns with the combination of LC and non-polar stationary phases. Using this column, designated as the ICB-PAH column, separation of the USEPA 16 priority PAH in addition to other isomeric PAH (except benzo[j]fluoranthene) is achieved. Complete separation of 16 priority PAH was achieved in less than 5 minutes on a 6 m 0.10 mm ID column, and in less than 7 minutes on a 15 m 0.25 mm ID column. Separations of 16 priority PAH plus five additional isomeric PAH on LC, non-polar, and a combination of LC and non-polar stationary phase columns are discussed.
引用
收藏
页码:165 / 180
页数:16
相关论文
共 50 条
  • [1] New nano stationary phase GC capillary columns for fast analysis of PAH by GC and GC/MS
    Britten, Allen J.
    Naikwadi, Krishnat P.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2009, 89 (15) : 1113 - 1123
  • [2] Capillary GC columns
    不详
    CHIMICA OGGI-CHEMISTRY TODAY, 1999, 17 (09) : 57 - 57
  • [3] ANALYSIS OF ACIDIC METABOLITES BY CAPILLARY COLUMN GC AND GC/MS
    LIEBICH, HM
    JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1983, 6 (12): : 640 - 650
  • [4] Fast, accurate semivolatiles analysis using Rxi®-5Sil MS capillary GC columns
    Freeman, Robert
    Stidsen, Gary
    LC GC NORTH AMERICA, 2008, : 22 - 22
  • [5] ANALYSIS OF PESTICIDES IN NATURAL WATER BY CAPILLARY GC AND GC/MS
    Yamashita, Satoru
    Miyajima, Tohru
    Takino, Akihiko
    Yamagami, Takashi
    Nishi, Sueo
    Yamaguchi, Kenji
    ANALYTICAL SCIENCES, 1991, 7 : 1165 - 1166
  • [6] COUPLED SYSTEMS - CAPILLARY GC MS AND CAPILLARY GC FTIR
    SMITH, SL
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1984, 22 (04) : 143 - 148
  • [7] Automatic thermal desorption in GC and GC-MS analysis of volatile food components using conventional and chiral capillary columns
    Esteban, JL
    Valero, E
    Miranda, E
    Jimenez, MI
    MartinezCastro, I
    Sanz, J
    Morales, R
    LC GC-MAGAZINE OF SEPARATION SCIENCE, 1997, 15 (03): : 264 - &
  • [8] Capillary GC and GC/MS analysis of waste plastics combustion products
    Pacakova, V
    Jelinek, I
    Zoul, J
    CHEMICKE LISTY, 1996, 90 (06): : 398 - 401
  • [9] Fast, practical GC and GC-MS
    de Zeeuw, J
    Barnes, M
    AMERICAN LABORATORY, 2006, 38 (02) : 26 - 29
  • [10] CAPILLARY GC AND GC-MS OF PORPHYRINS AND METALLOPORPHYRINS
    MARRIOTT, PJ
    GILL, JP
    EVERSHED, RP
    EGLINTON, G
    MAXWELL, JR