Quantitative Assessment of Hyaline Cartilage Elasticity during Optical Clearing using Optical Coherence Elastography

被引:1
|
作者
Liu, Chih-Hao [1 ]
Singh, Manmohan [1 ]
Li, Jiasong [1 ]
Han, Zhaolong [1 ]
Wu, Chen [1 ]
Wang, Shang [2 ]
Idugboe, Rita [1 ]
Raghunathan, Raksha [1 ]
Zakharov, Valery P. [3 ]
Sobol, Emil N. [4 ]
Tuchin, Valery V. [3 ,5 ,6 ]
Twa, Michael [7 ]
Larin, Kirill V. [1 ,3 ,5 ]
机构
[1] Univ Houston, Dept Biomed Engn, Houston, TX 77204 USA
[2] Baylor Coll Med, Dept Mol Physiol & Biophys, Houston, TX 77030 USA
[3] Samara State Aerosp Univ, Dept Elect Engn, Samara 443086, Russia
[4] Moscow MV Lomonosov State Univ, Dept Phys, Moscow 119991, Russia
[5] Saratov NG Chernyshevskii State Univ, Dept Opt & Biophoton, Saratov 410012, Russia
[6] Tomsk State Univ, Interdisciplinary Lab Biophoton, Tomsk 634050, Russia
[7] Univ Houston, Coll Optometry, Houston, TX 77204 USA
关键词
Optical coherence elastography; Young's modulus; hyaline cartilage; optical clearing; GLUCOSE DIFFUSION; QUANTIFICATION; OCT; PORCINE; TISSUES;
D O I
10.1117/12.2079854
中图分类号
Q813 [细胞工程];
学科分类号
摘要
We report the first study on using optical coherence elastography (OCE) to quantitatively monitor the elasticity change of the hyaline cartilage during the optical clearing administrated by glucose solution. The measurement of the elasticity is verified using uniaxial compression test, demonstrating the feasibility of using OCE to quantify the Young's modulus of the cartilage tissue. As the results, we found that the stiffness of the hyaline cartilage increases during the optical clearing of the tissue. This study might be potentially useful for the early detection of osteoarthritis disease.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Quantitative Assessment of Hyaline Cartilage Elasticity During Optical Clearing Using Optical Coherence Elastography
    Liu, Chih-Hao
    Singh, Manmohan
    Li, Jiasong
    Han, Zhaolong
    Wu, Chen
    Wang, Shang
    Idugboe, Rita
    Raghunathan, Raksha
    Sobol, Emil N.
    Tuchin, Valery V.
    Twa, Michael
    Larin, Kirill V.
    SOVREMENNYE TEHNOLOGII V MEDICINE, 2015, 7 (01) : 44 - 51
  • [2] Nonlinear characterization of elasticity using quantitative optical coherence elastography
    Qiu, Yi
    Zaki, Farzana R.
    Chandra, Namas
    Chester, Shawn A.
    Liu, Xuan
    BIOMEDICAL OPTICS EXPRESS, 2016, 7 (11): : 4702 - 4710
  • [3] Quantitative optical coherence elastography as an inverse elasticity problem
    Dong, Li
    Wijesinghe, Philip
    Dantuono, James T.
    Sampson, David D.
    Munro, Peter R. T.
    Kennedy, Brendan F.
    Oberai, Assad A.
    OPTICAL ELASTOGRAPHY AND TISSUE BIOMECHANICS III, 2016, 9710
  • [4] Elasticity Measurement of Nasal Cartilage as a Function of Temperature Using Optical Coherence Elastography
    Liu, Chih-Hao
    Skryabina, M. N.
    Singh, Manmohan
    Li, Jiasong
    Wu, Chen
    Sobol, E.
    Larin, Kirill V.
    OPTICAL ELASTOGRAPHY AND TISSUE BIOMECHANICS II, 2015, 9327
  • [5] Characterization of nonlinear elasticity for biological tissue using quantitative optical coherence elastography
    Qiu, Yi
    Zaki, Farzana R.
    Chandra, Namas
    Chester, Shawn A.
    Liu, Xuan
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XXI, 2017, 10053
  • [6] Quantitative micro-elastography: imaging of tissue elasticity using compression optical coherence elastography
    Kennedy, Kelsey M.
    Chin, Lixin
    McLaughlin, Robert A.
    Latham, Bruce
    Saunders, Christobel M.
    Sampson, David D.
    Kennedy, Brendan F.
    SCIENTIFIC REPORTS, 2015, 5
  • [7] Quantitative micro-elastography: imaging of tissue elasticity using compression optical coherence elastography
    Kelsey M. Kennedy
    Lixin Chin
    Robert A. McLaughlin
    Bruce Latham
    Christobel M. Saunders
    David D. Sampson
    Brendan F. Kennedy
    Scientific Reports, 5
  • [8] Quantitative Compression Optical Coherence Elastography as an Inverse Elasticity Problem
    Dong, Li
    Wijesinghe, Philip
    Dantuono, James T.
    Sampson, David D.
    Munro, Peter R. T.
    Kennedy, Brendan F.
    Oberai, Assad A.
    IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2016, 22 (03) : 277 - 287
  • [9] Quantitative assessment of corneal elasticity distribution after FS-LASIK using optical coherence elastography
    Han, Xiao
    Zhang, Yubao
    Shi, Gang
    Liu, Guo
    Ai, Sizhu
    Wang, Yidi
    Zhang, Qin
    He, Xingdao
    JOURNAL OF BIOPHOTONICS, 2024, 17 (04)
  • [10] In situ assessment of lens elasticity with noncontact optical coherence elastography
    Chen, Yulei
    Ye, Shuling
    Wang, Qingying
    Shen, Meixiao
    Lu, Fan
    Qu, Jia
    Zhu, Dexi
    BIOMEDICAL OPTICS EXPRESS, 2022, 13 (12) : 6671 - 6681