Comparisons of multiple automated anatomy-based image-guidance methods for patient setup before head/neck external beam radiotherapy

被引:0
|
作者
Dogan, Nesrin [1 ]
Song, Shiyu [1 ]
Saleh, Habeeb [1 ]
Wu, Jian [1 ]
Murphy, Martin J. [1 ]
机构
[1] Virginia Commonwealth Univ, Dept Radiat Oncol, Med Ctr, Richmond, VA 23298 USA
来源
关键词
image registration; image-guided setup; setup uncertainty; registration error; head/neck radiotherapy; COMPUTED-TOMOGRAPHY; CT; REGISTRATION; TOMOTHERAPY;
D O I
10.1120/jacmp.v12i1.3337
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose was to assess the variability in automated translational head/neck setup corrections computed from several different imaging modalities and rigid registration methods using patient anatomy. Shifts were calculated using three commercial and one in-house automated rigid registration methods for nine head/neck patients who were imaged with three different image-guidance systems. The mean difference between the daily isocenter shifts determined by the four methods ranged from 2.8 to 12.5 mm for all of the test cases. These differences are much greater than the variability observed for a rigid imaging phantom. Image-guided setup procedures have an uncertainty that depends on the imaging modality, the registration algorithm, the image resolution and the image content. In the absence of an absolute ground truth, the variation in the shifts calculated by several different methods provides a useful estimate of that uncertainty.
引用
收藏
页码:76 / 85
页数:10
相关论文
共 11 条
  • [1] Comparisons of Multiple Anatomy-based Image-guidance Methods for Patient Setup before Head and Neck External-beam Radiotherapy
    Murphy, M.
    Wu, J.
    Song, S.
    Dogan, N.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S684 - S685
  • [2] Comparison of Multiple 3D-3D Anatomy-Based Rigid Image Registration Methods for Prostate Patient Setup Before External-Beam Radiotherapy
    Wu, J.
    Murphy, M.
    [J]. MEDICAL PHYSICS, 2008, 35 (06)
  • [3] Interfraction Patient Setup for Multiple Volumetric-based Image Guidance Systems for Head and Neck IMRT
    Qi, X.
    Lee, S.
    Hu, A.
    Lee, P.
    Li, X.
    DeMarco, J.
    Okhovat, J.
    Steinberg, M.
    Kupelian, P.
    Low, D.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S772 - S772
  • [4] Effects of remedies made in patient setup process on residual setup errors and margins in head and neck cancer radiotherapy based on 2D image guidance
    Kapanen, Mika
    Laaksomaa, Marko
    Tulijoki, Tapio
    Kellokumpu-Lehtinen, Pirkko-Liisa
    Hyodynmaa, Simo
    [J]. REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2015, 20 (04) : 292 - 298
  • [5] A Study on Image Guided Radiotherapy Using Cone-Beam Computed Tomography (CBCT) for Head and Neck Cancer IMRT Patient Setup
    Tang, X.
    Chera, B.
    Lian, J.
    Deschesne, K.
    Chang, S.
    [J]. MEDICAL PHYSICS, 2010, 37 (06)
  • [6] Assessment of Interfraction Patient Setup for Head-and-Neck Cancer Intensity Modulated Radiation Therapy Using Multiple Computed Tomography-Based Image Guidance
    Qi, X. Sharon
    Hu, Angie Y.
    Lee, Steve P.
    Lee, Percy
    DeMarco, John
    Li, X. Allen
    Steinberg, Michael L.
    Kupelian, Patrick
    Low, Daniel
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 86 (03): : 432 - 439
  • [7] Evaluation of interfraction patient setup errors for image-guided prostate and head-and-neck radiotherapy using kilovoltage cone beam and megavoltage fan beam computed tomography
    Qi, X. Sharon
    Wu, Sutan
    Newman, Francis
    Li, X. Allen
    Hu, Angie Y.
    [J]. JOURNAL OF RADIOTHERAPY IN PRACTICE, 2013, 12 (04) : 334 - 343
  • [8] Estimation of adequate setup margins and threshold for position errors requiring immediate attention in head and neck cancer radiotherapy based on 2D image guidance
    Kapanen, Mika
    Laaksomaa, Marko
    Tulijoki, Tapio
    Peltola, Seppo
    Wigren, Tuija
    Hyodynmaa, Simo
    Kellokumpu-Lehtinen, Pirkko-Liisa
    [J]. RADIATION ONCOLOGY, 2013, 8
  • [9] Estimation of adequate setup margins and threshold for position errors requiring immediate attention in head and neck cancer radiotherapy based on 2D image guidance
    Mika Kapanen
    Marko Laaksomaa
    Tapio Tulijoki
    Seppo Peltola
    Tuija Wigren
    Simo Hyödynmaa
    Pirkko-Liisa Kellokumpu-Lehtinen
    [J]. Radiation Oncology, 8
  • [10] Daily Image Guidance with Cone-beam Computer Tomography Reduces Setup Margin Compared with 2D Megavoltage Imaging for Head and Neck Intensity Modulated Radiotherapy
    Tanzler, E.
    Samant, S.
    Liu, C.
    Amdur, R. J.
    Mendenhall, W. M.
    Yeung, A. R.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S175 - S176