Reference values of impulse oscillometry (IOS) for healthy Chinese children aged 4-17 years

被引:5
|
作者
Wu, Jinhong [1 ]
Zhang, Hao [2 ]
Shi, Yongsheng [3 ]
Wang, Jinrong [4 ]
Han, Yuling [5 ]
Zhang, Qiaoling [6 ]
Wang, Ning [7 ]
Liu, Sha [8 ]
Zhang, Yuehua [9 ]
Zi, Huifen [10 ]
Wang, Fei [11 ]
Liu, Aihong [12 ]
Song, Yuxin [13 ]
Jia, ChunMei [14 ]
Feng, Yong [15 ]
Liu, Quanhua [16 ]
Wan, Liya [17 ]
Ji, Minghong [18 ]
Long, Zhen [19 ]
Huang, Jianfeng [20 ]
Liu, Li [21 ]
Sun, Yun [22 ]
Tang, Suping [23 ]
Dong, Xiaoyan [24 ]
Zhou, Xiaojian [25 ]
Jiang, Wenhui [26 ]
Shen, Li [27 ]
Jiang, Haohua [27 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Med, Shanghai Childrens Med Ctr, Dept Resp Med, Shanghai 200127, Peoples R China
[2] Shanghai Jiao Tong Univ, Sch Med, Shanghai Childrens Med Ctr, Dept Internal Med, Shanghai 200127, Peoples R China
[3] Matern & Child Care Hosp Gansu Prov, Dept Pediat Resp, Lanzhou 730050, Gansu, Peoples R China
[4] Shandong First Med Univ, Affiliated Prov Hosp, Dept Pediat Resp, Jinan 250021, Peoples R China
[5] Shandong Univ, Qilu Childrens Hosp, Dept Resp, Jinan 250022, Peoples R China
[6] Maternal & Child Hlth Hosp Inner Mongolia Autonom, Dept Pediat Resp, Hohhot 010020, Peoples R China
[7] Xian Childrens Hosp, Asthma Ctr, Xian 710003, Peoples R China
[8] Chongqing Med Univ, Childrens Hosp, Dept Resp Med, Chongqing 400014, Peoples R China
[9] Cent South Univ, Affiliated Haikou Hosp, Xiangya Sch Med, Pediat Infect Dis Ward, Haikou 570208, Hainan, Peoples R China
[10] Baotou Cent Hosp, Dept Pediat, Baotou 014040, Peoples R China
[11] Guiyang Childrens Hosp, Guiyang Maternal & Child Hlth Hosp, Dept Pediat Resp, Guiyang 550003, Peoples R China
[12] Childrens Hosp Shanxi, Dept Resp Med, Taiyuan 030013, Peoples R China
[13] Harbin Childrens Hosp, Dept Allergy, Harbin 150010, Peoples R China
[14] Baotou Childrens Hosp, Hosp Baotou 4, Dept Pediat Resp, Baotou 014030, Peoples R China
[15] China Med Univ, Shengjing Hosp, Dept Pediat, Shenyang 110004, Peoples R China
[16] Shanghai Jiao Tong Univ, Sch Med, Xinhua Hosp, Dept Pulmonol, Shanghai 200092, Peoples R China
[17] Tianjin Childrens Hosp, Resp Dept, Tianjin 300074, Peoples R China
[18] USTC, Anhui Prov Hosp, Affiliated Hosp 1, Dept Pediat, Hefei 230001, Peoples R China
[19] Huazhong Univ Sci & Technol, Maternal & Child Hlth Hosp Hubei Prov, Tongji Med Coll, Dept Pediat Resp Med, Wuhan 430070, Peoples R China
[20] Fudan Univ, Childrens Hosp, Dept Pulmonol, Shanghai 201102, Peoples R China
[21] First Hosp Jilin Univ, Dept Pediat Resp, Changchun 130021, Peoples R China
[22] Yinchuan Women & Children Healthcare Hosp, Gen Pediat, Yinchuan 750001, Ningxia, Peoples R China
[23] Fujian Med Univ, Fuzhou Childrens Hosp, Dept Asthma & Tracheitis, Fuzhou 350000, Peoples R China
[24] Shanghai Jiao Tong Univ, Shanghai Childrens Hosp, Dept Pulmonol, Shanghai 200040, Peoples R China
[25] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 1, Dept Pediat, Shanghai 200080, Peoples R China
[26] Guangzhou Women & Childrens Med Ctr, Dept Resp, Guangzhou 510623, Peoples R China
[27] Shanghai Jiao Tong Univ, Shanghai Chest Hosp, Dept Resp, Shanghai 200025, Peoples R China
关键词
Impulse oscillometry; Pulmonary function test; Normal predicted value; Child; BRONCHODILATOR RESPONSE; PULMONARY-FUNCTION; LUNG-FUNCTION; DYSFUNCTION; PARAMETERS; RESISTANCE; IMPEDANCE; EXERCISE; ASTHMA;
D O I
10.1186/s12931-022-02080-z
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Objective To establish the predicted value of pulmonary function determined by impulse oscillometry (IOS) in children (4-17 years old) in China. Methods A total of 6270 healthy children aged 4-17 years in China were included. The Master Screen IOS pulmonary function device (Jaeger Co, Germany) was used to detect the respiratory impedance (Zrs), resonant frequency (Fres), respiratory system resistance (Rrs) and respiratory system reactance (Xrs) at various oscillation frequencies, and the indices above were analysed. Stepwise multivariate regression was used to establish the regression equation of related parameters of IOS in different sexes, ages, height, and weight. Results The differences in the main IOS parameters between different age stages were statistically significant regardless of sex (P < 0.05). The stepwise multivariate regression analysis showed that IOS parameters were related to height, age, and weight, and most IOS parameters were most closely related to height (the absolute value of the regression coefficient was the largest). With increasing age and height, the values of Z(5), R-5, R-20, R-5-R-20, and Fres decreased, while the value of X-5 increased. Through height, age, and weight, we obtained the normal predicted values equation of children's IOS parameters. Compared with the other reference equations, our reference equation is more suitable for Chinese children. Conclusions The study revealed the reference values of IOS parameters in healthy Chinese children. In the evaluation of results for lung function measurements, this predicted value equation is more consistent with the characteristics of Chinese children than other reference equations. Clinical Trial: ChiCTR: 1800019029.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Reference values of impulse oscillometry (IOS) for healthy Chinese children aged 4–17 years
    Jinhong Wu
    Hao Zhang
    Yongsheng Shi
    Jinrong Wang
    Yuling Han
    Qiaoling Zhang
    Ning Wang
    Sha Liu
    Yuehua Zhang
    Huifen Zi
    Fei Wang
    Aihong Liu
    Yuxin Song
    ChunMei Jia
    Yong Feng
    Quanhua Liu
    liya Wan
    Minghong Ji
    Zhen Long
    Jianfeng Huang
    Li Liu
    Yun Sun
    Suping Tang
    Xiaoyan Dong
    Xiaojian Zhou
    Wenhui Jiang
    Li Shen
    Haohua Jiang
    Respiratory Research, 23
  • [2] Reference values of impulse oscillometry (IOS) for healthy Chinese children aged 4-17 years (vol 23, 182, 2022)
    Wu, Jinhong
    Zhang, Hao
    Shi, Yongsheng
    Wang, Jinrong
    Han, Yuling
    Zhang, Qiaoling
    Wang, Ning
    Liu, Sha
    Zhang, Yuehua
    Zi, Huifen
    Wang, Fei
    Liu, Aihong
    Song, Yuxin
    Jia, ChunMei
    Feng, Yong
    Liu, Quanhua
    Wan, Liya
    Ji, Minghong
    Long, Zhen
    Huang, Jianfeng
    Liu, Li
    Sun, Yun
    Tang, Suping
    Dong, Xiaoyan
    Zhou, Xiaojian
    Jiang, Wenhui
    Shen, Li
    Jiang, Haohua
    RESPIRATORY RESEARCH, 2023, 24 (01)
  • [3] Correction: Reference values of impulse oscillometry (IOS) for healthy Chinese children aged 4–17 years
    Jinhong Wu
    Hao Zhang
    Yongsheng Shi
    Jinrong Wang
    Yuling Han
    Qiaoling Zhang
    Ning Wang
    Sha Liu
    Yuehua Zhang
    Huifen Zi
    Fei Wang
    Aihong Liu
    Yuxin Song
    ChunMei Jia
    Yong Feng
    Quanhua Liu
    liya Wan
    Minghong Ji
    Zhen Long
    Jianfeng Huang
    Li Liu
    Yun Sun
    Suping Tang
    Xiaoyan Dong
    Xiaojian Zhou
    Wenhui Jiang
    Li Shen
    Haohua Jiang
    Respiratory Research, 24
  • [4] Reference values of impulse oscillometry (IOS) for healthy Indian adults
    Moitra, Subhabrata
    Moitra, Saibal
    Ghosh, A. K.
    Sengupta, S.
    Das, P. K.
    Das, A.
    Mitra, R.
    Murgia, N.
    Usmani, O. S.
    INTERNATIONAL JOURNAL OF TUBERCULOSIS AND LUNG DISEASE, 2020, 24 (05) : 536 - 539
  • [5] REFERENCE EQUATIONS AND VALUES FOR IMPULSE OSCILLOMETRY SYSTEM (IOS) IN BRAZILIAN HEALTHY CHILDREN AND ADOLESCENTS
    de Assumpcao, Maira Seabra
    Ribeiro, Jose Dirceu
    Goncalves, Renata Maba
    Martins, Renata
    Bobbio, Tatiana Godoy
    Santos Schivinski, Camila Isabel
    PEDIATRIC PULMONOLOGY, 2016, 51 : S8 - S8
  • [6] IMPULSE OSCILLOMETRY REFERENCE VALUES FOR TURKISH CHILDREN AGED THREE TO EIGHT YEARS
    Yilmaz, Ozge
    Tunca, Seda
    Lombardi, Enrico
    Yasar, Adem
    Yuksel, Hasan
    EUROPEAN RESPIRATORY JOURNAL, 2024, 64
  • [7] Reference values for respiratory sinusoidal oscillometry in children aged 3 to 17 years
    Ducharme, Francine M.
    Smyrnova, Anna
    Lawson, Christiane C.
    Miles, Laura May
    PEDIATRIC PULMONOLOGY, 2022, 57 (09) : 2092 - 2102
  • [8] Transient Reference Values for Impulse Oscillometry for Children Aged 3-18 Years
    Nowowiejska, Boena
    Tomalak, Waldemar
    Radlinski, Jakub
    Siergiejko, Grzegorz
    Latawiec, Wojciech
    Kaczmarski, Maciej
    PEDIATRIC PULMONOLOGY, 2008, 43 (12) : 1193 - 1197
  • [9] Reference values of respiratory impedance with impulse oscillometry in healthy Chinese adults
    Liang, Xiao-Lin
    Gao, Yi
    Guan, Wei-Jie
    Du, Jing
    Chen, Li
    Han, Wen
    Liu, Jin-Ming
    Lu, Yong
    Peng, Yi
    Zhao, Bing-Rong
    Wang, Tao
    Zheng, Jin-Ping
    JOURNAL OF THORACIC DISEASE, 2021, 13 (06) : 3680 - +
  • [10] Lung volumes in healthy Afro-Caribbean children aged 4-17 years
    Sylvester, KP
    Milligan, P
    Patey, RA
    Rafferty, GF
    Greenough, A
    PEDIATRIC PULMONOLOGY, 2005, 40 (02) : 109 - 112