Changes in Intraocular Pressure During Hemodialysis: A Meta-analysis

被引:5
|
作者
Chen, Szu-Han [1 ]
Lu, Da-Wen [4 ]
Ku, Wan-Chen [2 ]
Chuang, Lan-Hsin [2 ]
Ferng, Shyang-Hwa [5 ]
Chen, Yi-Ju [7 ]
Lu, Yi-Hsuan [6 ]
Chai, Pony Yee-Chee [3 ]
机构
[1] Chang Gung Mem Hosp, Dept Phys Med & Rehabil, Keelung, Taiwan
[2] Chang Gung Mem Hosp, Dept Ophthalmol, Keelung, Taiwan
[3] Chang Gung Mem Hosp, Dept Pharm, Keelung, Taiwan
[4] Taipei Med Univ, Triserv Gen Hosp, Dept Ophthalmol, Taipei, Taiwan
[5] Taipei Med Univ, Cathay Gen Hosp, Dept Internal Med, Div Nephrol, Taipei, Taiwan
[6] Taipei Med Univ, Coll Publ Hlth, Sch Publ Hlth, Taipei, Taiwan
[7] Univ Pittsburgh Med Ctr UPMC Pinnacle Harrisburg, Dept Internal Med, Harrisburg, PA USA
关键词
hemodialysis; intraocular pressure; moderator; dialysate; glaucoma; PREVENTION; ELEVATION; THICKNESS; PATIENT;
D O I
10.1097/IJG.0000000000001842
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Precis: Acetate dialysate causes elevation of intradialytic intraocular pressure (IOP) and contributed to the rise of IOP in the early years of hemodialysis (HD). Glaucoma, narrow-angle, or impaired aqueous outflow is another moderator causing a rise of intradialytic IOP. Purpose: Severe IOP elevation during HD has been described in many case reports. However, the results of primary studies are conflicting. This meta-analysis examined the impact of HD on IOP and explored the potential moderators. Methods: Medline, PubMed, Embase, Web of Science, and Cochrane were systematically searched. Before-after studies reporting the change of IOP during HD were included. Intradialytic IOP changes were calculated based on 4 different definitions: highest-baseline, lowest-baseline, max-baseline, and end-baseline IOP difference. Standardized mean difference (SMD) was pooled using the random-effects model. Results: Fifty-three studies involving 1903 participants and 2845 eyes were included. Overall data pooling showed no significant rise in intradialytic IOP. However, subgroup analysis showed an intradialytic IOP rise before 1986 (SMD: 0.593; 95% confidence interval: 0.169-1.018; max-baseline IOP difference as representative; most studies using acetate dialysate), no change between 1986 and 2005 (using both acetate and bicarbonate), and a decline after 2005 (SMD: -0.222; 95% confidence interval: -0.382 to -0.063; entirely using bicarbonate). Multivariable meta-regression showed only the type of dialysate, but not publication year or other potential factors, as a significant moderator. Glaucoma was found to be another significant moderator independent of the dialysate effect in bivariate meta-regression. Conclusions: IOP elevation in the early years of HD with the use of acetate dialysate is less of a clinical problem following its substitution with bicarbonate dialysate. However, physicians should still be cautious of potential IOP changes in the HD population with glaucoma.
引用
收藏
页码:866 / 873
页数:8
相关论文
共 50 条
  • [1] CHANGES IN INTRAOCULAR PRESSURE DURING HEMODIALYSIS
    SITPRIJA, V
    HOLMES, JH
    ELLIS, PP
    INVESTIGATIVE OPHTHALMOLOGY, 1964, 3 (03): : 273 - 284
  • [2] INTRAOCULAR PRESSURE CHANGES DURING HEMODIALYSIS
    RAMSELL, JT
    ELLIS, PP
    PATERSON, CA
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1971, 72 (05) : 926 - &
  • [3] CHANGES OF INTRAOCULAR-PRESSURE DURING HEMODIALYSIS
    YOON, YS
    KOO, WS
    YANG, YS
    LEE, KH
    CHOI, EJ
    BANG, BK
    LEE, JY
    YANG, HY
    KIDNEY INTERNATIONAL, 1991, 39 (01) : 210 - 210
  • [4] Erratum to: Intraocular pressure changes during hemodialysis
    Vassilios Liakopoulos
    Paraskevi Demirtzi
    Dimitrios G. Mikropoulos
    Konstantinos Leivaditis
    Evangelia Dounousi
    Anastasios G. P. Konstas
    International Urology and Nephrology, 2015, 47 : 1691 - 1691
  • [5] Changes in intraocular pressure and central corneal thickness during pregnancy: a systematic review and Meta-analysis
    Wang, Chao
    Li, Ai-Ling
    Pang, Yu
    Lei, Ying-Qing
    Yu, Ling
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2017, 10 (10) : 1573 - 1579
  • [6] Changes in intraocular pressure and central corneal thickness during pregnancy:a systematic review and Meta-analysis
    Chao Wang
    Ai-Ling Li
    Yu Pang
    Ying-Qing Lei
    Ling Yu
    International Journal of Ophthalmology, 2017, (10) : 1573 - 1579
  • [7] CHANGES IN INTRAOCULAR PRESSURE DURING HEMODIALYSIS AND THE ROLE OF ULTRAFILTRATION RATE
    Rroji, Merita
    Seferi, Saimir
    Eglantina, Bulica
    Likaj, Erjola
    Barbullushi, Myftar
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2019, 34
  • [8] Intraocular Pressure Changes During Hemodialysis and the Role of Blood Glucose
    Ahmadi, Farrokhlagha
    Mohebi-Nejad, Azin
    IRANIAN JOURNAL OF KIDNEY DISEASES, 2013, 7 (01) : 5 - 7
  • [9] INTRAOCULAR-PRESSURE DURING HEMODIALYSIS
    BROEKEMA, N
    VANBIJSTERVELD, OP
    DEBOSKUIL, RJC
    OPHTHALMOLOGICA, 1988, 197 (02) : 60 - 64
  • [10] INTRAOCULAR-PRESSURE DURING HEMODIALYSIS
    BURN, RA