Lidloading and intraocular pressure

被引:2
|
作者
Schrom, T
Habermann, A
Wernecke, K
Scherer, H
Duncker, G
机构
[1] Hals Nasen Ohren Klin, D-10117 Berlin, Germany
[2] Univ Halle Wittenberg, Klin Augenheilkunde, Halle Saale, Germany
[3] Humboldt Univ, Inst Med Biometrie, Berlin, Germany
关键词
intraocular pressure; lidloading; facial palsy;
D O I
10.1055/s-2004-813940
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: Implantation of rigid gold or platinum lid weights (lidloading) represents the most common method for therapy of patients with lagophthalmus as a result of facial palsy. In a more recent approach also flexible platinum chains have been used. Glaucoma has frequently been described as a contraindication for lidloading. The aim of this study was to proof if lid weights lead to an increase of the intraocular pressure (IOP). Patients and methods: In a prospective study the IOP has been measured before and after implantation of 46 rigid gold implants and 39 flexible platinum chains in patients with paralytic lagophthalmos. Results: Neither the implantation of rigid gold implants nor the use of the flexible platinum chain lead to a statistically significant change of the IOP. There was also no difference between the two groups. Conclusion: With this study we could demonstrate that glaucoma is not an absolute contraindication for the use of lid weights in patients with paralytic lagophthalmos. Moreover a lid weight is easily removable if complications should occur.
引用
收藏
页码:46 / 49
页数:4
相关论文
共 50 条
  • [1] Lidloading in facial palsy
    Schrom, T.
    LARYNGO-RHINO-OTOLOGIE, 2007, 86 (09) : 634 - 636
  • [2] Personalizing Intraocular Pressure: Target Intraocular Pressure in the Setting of 24-Hour Intraocular Pressure Monitoring
    Sit, Arthur J.
    Pruet, Christopher M.
    ASIA-PACIFIC JOURNAL OF OPHTHALMOLOGY, 2016, 5 (01): : 17 - 22
  • [3] INTRAOCULAR PRESSURE
    不详
    BMJ-BRITISH MEDICAL JOURNAL, 1958, 1 (FEB15): : 387 - 388
  • [4] Intraocular pressure
    Murgatroyd, Harry
    Bembridge, Jane
    BJA EDUCATION, 2008, 8 (03) : 100 - 103
  • [5] INTRAOCULAR PRESSURE
    WRIGHT, RE
    BMJ-BRITISH MEDICAL JOURNAL, 1958, 1 (MAR22): : 709 - 710
  • [6] Single intraocular pressure measurements and diurnal intraocular pressure profiles
    Jonas, JB
    Budde, W
    Stroux, A
    Oberacher-Velten, IM
    Jünemann, A
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2005, 139 (06) : 1136 - 1137
  • [7] THE INTERRELATIONSHIP BETWEEN INTRAOCULAR-PRESSURE AND HONAN INTRAOCULAR-PRESSURE REDUCER PRESSURE
    GREEN, K
    HARMAN, D
    CHEEKS, L
    CURRENT EYE RESEARCH, 1986, 5 (08) : 621 - 623
  • [8] Intraocular pressure variability in patients who reached target intraocular pressure
    Malerbi, FK
    Hatanaka, M
    Vessani, RM
    Susanna, R
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2005, 89 (05) : 540 - 542
  • [9] INTRAOCULAR FEEDBACK MECHANISMS OF INTRAOCULAR PRESSURE IN RABBITS
    VALEBJORG, H
    ACTA OPHTHALMOLOGICA, 1970, 48 (04) : 809 - +
  • [10] EFFECT OF INTRAOCULAR GAS ON INTRAOCULAR-PRESSURE
    ARONOWITZ, JD
    BRUBAKER, RF
    ARCHIVES OF OPHTHALMOLOGY, 1976, 94 (07) : 1191 - 1196