Evaluation of photografted charged sites within polymer monoliths in capillary columns using contactless conductivity detection

被引:34
|
作者
Connolly, Damian
O'Shea, Vincent
Clark, Paul
O'Connor, Brendan
Paull, Brett [1 ]
机构
[1] Dublin City Univ, Sch Chem Sci, Ctr Bioanalyt Sci, Dublin 9, Ireland
[2] Dublin City Univ, Sch Biotechnol, Ctr Bioanalyt Sci, Dublin 9, Ireland
关键词
contactless conductivity detection; polymer monolithic phase; photografted protein;
D O I
10.1002/jssc.200700365
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Capacitively coupled contactless conductivity detection ((CD)-D-4) is presented as a novel and versatile means of visualising discrete zones of charged functional groups grafted onto polymer based monoliths. Monoliths were first formed within 100 mu m UV-transparent fused silica capillaries. Photografting methods were subsequently used to graft a charged functional monomer, 2-acrylamido-2-methyl-1-propanesulfonic acid, onto discrete regions of the monolith using a photomask. Post-modification monolith evaluation involves scanning the (CD)-D-4 detector along the length of the monolith to obtain a profile of the exact spatial location of grafted charged functionalities with millimetre accuracy. The methodology was extended to the visualisation of several zones of immobilised protein (bovine serum albumin) using photografted azlactone groups to enable covalent attachment of the protein to the monolith at precise locations along its length. In addition, the extent of non-specific binding of protein to the ungrafted regions of the monolith due to hydrophobic interactions could be monitored as an increase in background conductivity of the stationary phase. Finally, the technique was cross-validated using digital photography in combination with a UV light source by immobilising green fluorescent protein in discrete zones and comparing the results obtained using both complementary techniques.
引用
收藏
页码:3060 / 3068
页数:9
相关论文
共 50 条
  • [1] Capillary electrophoresis with direct and contactless conductivity detection on a polymer microchip
    Weber, G
    Jöhnck, M
    Siepe, D
    Neyer, A
    Hergenröder, R
    MICRO TOTAL ANALYSIS SYSTEMS 2000, PROCEEDINGS, 2000, : 383 - 386
  • [2] Evaluation of the detection of biomolecules in capillary electrophoresis by contactless conductivity measurement
    Abad-Villar, Eva M.
    Kuban, Pavel
    Hauser, Peter C.
    JOURNAL OF SEPARATION SCIENCE, 2006, 29 (07) : 1031 - 1037
  • [3] Capillary electrochromatography with contactless conductivity detection for the determination of some inorganic and organic cations using monolithic octadecylsilica columns
    Mai, Thank Duc
    Pham, Hung Viet
    Hauser, Peter C.
    ANALYTICA CHIMICA ACTA, 2009, 653 (02) : 228 - 233
  • [4] Rapid Detection of AGs using Microchip Capillary Electrophoresis Contactless Conductivity Detection
    Zhu, Gangzhi
    Bao, Chunjie
    Liu, Wenfang
    Yan, Xingxing
    Liu, Lili
    Xiao, Jian
    Chen, Chuanpin
    CURRENT PHARMACEUTICAL ANALYSIS, 2019, 15 (01) : 9 - 16
  • [5] Evaluation of capillary ion exchange stationary phase coating distribution and stability using radial capillary column contactless conductivity detection
    Gillespie, Eoin
    Macka, Miroslav
    Connolly, Damien
    Paull, Brett
    ANALYST, 2006, 131 (08) : 886 - 888
  • [6] Quantification of plasma lactate concentrations using capillary electrophoresis with contactless conductivity detection
    Pormsila, Worapan
    Morand, Rejane
    Kraehenbuehl, Stephan
    Hauser, Peter C.
    ELECTROPHORESIS, 2011, 32 (08) : 884 - 889
  • [7] Characterization of cationic copolymers by capillary electrophoresis using indirect UV detection and contactless conductivity detection
    Anik, Nadia
    Airiau, Marc
    Labeau, Marie-Pierre
    Chi-Thanh Vuong
    Cottet, Herve
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1219 : 188 - 194
  • [8] Using scanning contactless conductivity to optimise photografting procedures and capacity in the production of polymer ion-exchange monoliths
    Gillespie, Eoin
    Connolly, Damian
    Paull, Brett
    ANALYST, 2009, 134 (07) : 1314 - 1321
  • [9] Analysis of Ecstasy Tablets Using Capillary Electrophoresis with Capacitively Coupled Contactless Conductivity Detection
    Porto, Suely K. S. S.
    Nogueira, Thiago
    Blanes, Lucas
    Doble, Philip
    Sabino, Bruno D.
    do Lago, Claudimir L.
    Angnes, Lucio
    JOURNAL OF FORENSIC SCIENCES, 2014, 59 (06) : 1622 - 1626
  • [10] THE ANALYSIS OF SMALL IONS WITH PHYSIOLOGICAL IMPLICATIONS USING CAPILLARY ELECTROPHORESIS WITH CONTACTLESS CONDUCTIVITY DETECTION
    Neaga, Ioan-Ovidiu
    Iacob, Bogdan Cezar
    Bodoki, Ede
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2014, 37 (14) : 2072 - 2090