Initial patient imaging with an optimised radiotherapy beam for portal imaging

被引:12
|
作者
Flampouri, S
McNair, HA
Donovan, EM
Evans, PM
Partridge, M
Verhaegen, F
Nutting, CM
机构
[1] Inst Canc Res, Joint Phys Dept, Sutton SM2 5PT, Surrey, England
[2] Royal Marsden NHS Trust, Joint Phys Dept, Sutton SM2 5PT, Surrey, England
[3] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
[4] Harvard Univ, Sch Med, Boston, MA USA
[5] Royal Marsden NHS Trust, Dept Radiotherapy, Sutton, Surrey, England
[6] McGill Univ, Dept Med Phys, Montreal, PQ, Canada
[7] Royal Marsden NHS Trust, Head & Neck Unit, London, England
[8] Inst Canc Res, London SW3 6JB, England
关键词
portal imaging; low-Z target;
D O I
10.1016/j.radonc.2005.04.006
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: To investigate the feasibility and the advantages of a portal-imaging mode on a medical accelerator, consisting of a thin low-Z bremsstrahlung target and a thin Gd2O2S/film detector, for patient imaging. Patients and methods: The international code of practice for high-energy photon dosimetry was used to calibrate dosimetry instruments for the imaging beam produced by 4.75 MeV electrons hitting a 6 mm thick aluminium target. Images of the head and neck of a humanoid phantom were taken with a mammography film system and the dose in the phantom was measured with TLDs calibrated for this beam. The first head and neck patient images are compared with conventional images (taken with the treatment beam on a film radiotherapy verification detector). Visibility of structures for six patients was evaluated. Results: Images of the head and neck of a humanoid phantom, taken with both imaging systems showed that the contrast increased dramatically for the new system while the dose required to form an image was less than 10(-2) Gy. The patient images taken with the new and the conventional systems showed that air-tissue interfaces were better defined in the new system image. Anatomical structures, visible on both films, are clearer with the new system. Additionally, bony structures, such as vertebrae, were clearly visible only with the new system. The system under evaluation was significantly better for all features in lateral images and most features in anterior images. Conclusions: This pilot study of the new portal imaging system showed the image quality is significantly improved. (C) 2005 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:63 / 71
页数:9
相关论文
共 50 条
  • [1] Feasibility study of patient positioning verification in electron beam radiotherapy with an electronic portal imaging device (EPID)
    Ramm, U.
    Koehn, J.
    Dominguez, R. Rodriguez
    Licher, J.
    Koch, N.
    Kara, E.
    Scherf, C.
    Roedel, C.
    Weiss, C.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (02): : 215 - 220
  • [2] AN ONLINE ELECTRONIC PORTAL IMAGING-SYSTEM FOR EXTERNAL BEAM RADIOTHERAPY
    LAM, KS
    PARTOWMAH, M
    LAM, WC
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1986, 59 (706): : 1007 - 1013
  • [3] Importance of daily electronic portal imaging in radiotherapy
    Bell, L. J.
    Shakespeare, T. P.
    Willis, A.
    [J]. JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2008, 52 (04) : 414 - 418
  • [4] Portal imaging in conformal radiotherapy of lung cancer
    De Neve, W
    Derycke, S
    De Gersem, W
    Vakaet, L
    De Wagter, C
    [J]. TREATMENT OPTIMIZATION FOR LUNG CANCER: FROM CLASSICAL TO INNOVATIVE PROCEDURES, 1998, : 109 - 113
  • [5] Portal imaging for radiotherapy treatment verification and correction
    van der Vight, LP
    van Lin, ENJT
    Visser, AG
    [J]. RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S14 - S15
  • [6] Additional verification of patient positioning in fractionated stereotatic radiotherapy using electronic portal imaging
    Batel, V
    Germano, S
    Pereira, P
    Marques, F
    Mascarenhas, F
    [J]. RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S220 - S220
  • [7] Initial imaging in the trauma patient
    Wisner, DH
    [J]. WESTERN JOURNAL OF MEDICINE, 1998, 168 (01): : 37 - 39
  • [8] Low energy unflattened beam for portal imaging
    Tsechanski, A
    Faermann, S
    Krutman, Y
    [J]. PHYSICA MEDICA, 1997, 13 : 162 - 165
  • [9] A literature review of electronic portal imaging for radiotherapy dosimetry
    van Etmpt, Wouter
    McDermott, Leah
    Nijsten, Sebastiaan
    Wendling, Markus
    Lambin, Philippe
    Mijnheer, Ben
    [J]. RADIOTHERAPY AND ONCOLOGY, 2008, 88 (03) : 289 - 309
  • [10] The importance of daily electronic portal imaging (EPI) in radiotherapy
    Bell, L. J.
    Shakespeare, T. P.
    Willis, A.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S630 - S630