A simple measurement method of visceral fat accumulation by bioelectrical impedance analysis

被引:0
|
作者
Shiga, T. [1 ]
Oshima, Y. [1 ]
Kanai, H. [2 ]
Hirata, M. [3 ]
Hosoda, K. [3 ]
Nakao, K. [3 ]
机构
[1] Omron Healthcare Co Ltd, Dept Res & Dev, Ukyo Ku, 24 Yamanouchi Yamanoshita Cho, Kyoto 6150084, Japan
[2] Sophia Univ, Tokyo, Japan
[3] Kyoto Univ, Dept Med & Clinical Sci, Grad Sch Med, Kyoto, Japan
关键词
BIA; visceral fat; measurement; dual impedance; simple measurement;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Simple measurement of visceral fat accumulation is essential for diagnosis and treatment of metabolic syndrome. Bioelectrical impedance method is most suitable for theses measurements. However, measuring visceral fat volume without the influence of subcutaneous fat has been difficult because of the low spatial resolution of bioelectrical impedance method. In the present study, we have developed a simple method for the measurement of visceral fat accumulation using visceral fat bioelectrical impedance analysis (VF-BIA). For VF-BIA, an electric current (250 mu A, 50 kHz) was applied to electrodes bilaterally fixed on the hands and feet, and the voltage was measured between six pairs of electrodes placed around the trunk at the umbilical level. The impedance reflects the total amount of abdomen fat, in addition to obtain the impedance of the body surface which reflects the amount of subcutaneous fat, the voltage induced by applying electric current to the electrodes placed on the body surface around the trunk at the umbilical level was measured with electrodes between the stimulating electrodes. Regarding to measure these two impedance values we adopted the four electrodes method. The visceral fat area (VFA) was calculated using these two impedance values. Measurement results by this method correlated well with visceral fat area obtained from MRI image: r=0.820 and p<0.001. Our method is suggested to be useful for simple visceral fat measurement.
引用
收藏
页码:687 / +
页数:2
相关论文
共 50 条
  • [1] A new simple method for the measurement of visceral fat accumulation by bioelectrical impedance
    Ryo, M
    Maeda, K
    Onda, T
    Katashima, M
    Okumiya, A
    Nishida, M
    Yamaguchi, T
    Funahashi, T
    Matsuzawa, Y
    Nakamura, T
    Shimomura, I
    DIABETES CARE, 2005, 28 (02) : 451 - 453
  • [2] Visceral fat estimation method by bioelectrical impedance analysis and causal analysis
    Nakajima, Hiroshi
    Tasaki, Hiroshi
    Tsuchiya, Naoki
    Hamaguchi, Takehiro
    Shiga, Toshikazu
    INDEPENDENT COMPONENT ANALYSES, WAVELETS, NEURAL NETWORKS, BIOSYSTEMS, AND NANOENGINEERING IX, 2011, 8058
  • [3] Measurement of visceral fat by abdominal bioelectrical impedance analysis is beneficial in medical checkup
    Shoji, Kentaro
    Maeda, Kazuhisa
    Nakamura, Tadashi
    Funahashi, Tohru
    Matsuzawa, Yuji
    Shimomura, Iichiro
    OBESITY RESEARCH & CLINICAL PRACTICE, 2008, 2 (04) : 269 - 275
  • [4] Performance evaluation of the electrode configuration in bioelectrical impedance analysis for visceral fat measurement
    Kim, Kwangsoo
    Lee, Mi-hee
    Kim, Jungchae
    Jung, Seok Myung
    Jee, Sun Ha
    Yoo, Sun K.
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 892 - +
  • [5] The assessment of visceral fat accumulation by dual bioelectrical impedance analysis in weight reduction therapy
    Ida, Midori
    Hirata, Masakazu
    Mori, Eisaku
    Odori, Shinji
    Kondo, Eri
    Ebihara, Ken
    Masuzaki, Hiroaki
    Kiminori, Hosoda
    Ooshima, Hidetake
    Shiga, Toshikazu
    Nakao, Kazuwa
    ENDOCRINE JOURNAL, 2010, 57 : S414 - S414
  • [6] Validity of Visceral Fat Area Measurement by Bioelectrical Impedance Analysis in Japanese Obese Individuals
    Hamasaki, Hidetaka
    Furuta, Masashi
    Yanai, Hidekatsu
    CURRENT DIABETES REVIEWS, 2020, 16 (05) : 515 - 519
  • [7] Trial Evaluation of Visceral Fat Characteristics by Abdominal Bioelectrical Impedance Method
    Yamanaka, Yutaka
    Shinno, Hiromi
    Kurose, Satoshi
    Tsutsumi, Hiromi
    Kimura, Yutaka
    JOURNAL OF DIABETES & METABOLISM, 2013, 4 (08)
  • [8] A study of bioelectrical impedance analysis methods for practical visceral fat estimation
    Yoneda, M.
    Tasaki, H.
    Tsuchiya, N.
    Nakajima, H.
    Hamaguchi, T.
    Oku, S.
    Shiga, T.
    GRC: 2007 IEEE INTERNATIONAL CONFERENCE ON GRANULAR COMPUTING, PROCEEDINGS, 2007, : 622 - 627
  • [9] A New Measurement System of Visceral Fat Area by Bioelectrical Impedance Analysis in a Population of community-Dwelling
    Enomoto, Mika
    Adachi, Hisashi
    Hirai, Yuji
    Fukami, Ako
    Yoshikawa, Kuniko
    Esaki, Eishi
    Ogata, Kinuka
    Kasahara, Akiko
    Tsukagawa, Eri
    Yokoi, Kanako
    Nakamura, Sachiko
    Obuchi, Aya
    Yoshimura, Ayako
    Imaizumi, Tsutomu
    CIRCULATION, 2012, 126 (21)
  • [10] Estimating Visceral Fat Area by Multifrequency Bioelectrical Impedance
    Nagai, Masato
    Komiya, Hideaki
    Mori, Yutaka
    Ohta, Teruo
    Kasahara, Yasuhiro
    Ikeda, Yoshio
    DIABETES CARE, 2010, 33 (05) : 1077 - 1079