Minimum Separation Between Lightning Protection System And Non-Integrated Metallic Structures

被引:0
|
作者
Fallah, S. N. [1 ]
Gomes, C. [2 ]
Izadi, Mahdi [2 ]
Ab Kadir, M. Z. A. [2 ,3 ]
Ahmed, Rebaz J. [1 ]
Jasni, Jasronita Bt [2 ]
机构
[1] Univ Putra Malaysia, Dept Elect & Elect Engn, Serdang, Selangor, Malaysia
[2] Univ Putra Malaysia, CELP, Serdang, Selangor, Malaysia
[3] Univ Tenaga Nas, Inst Power Engn, Kuala Lumpur, Malaysia
关键词
Separation distance; lightning protection system (LPS); constant area criterion; voltage-time law;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In the event of a direct lightning strike to a protected building which is integrated with an electrical or electronic system installed on the roof such as roof-top PV system, dangerous arcing may occur between the external lightning protection system (LPS) and the conductive components of the electrical system. To prevent such side flashes, a minimum separation distance between the metallic components and the air termination system is required. Even though, IEC62305-3 Standard provides a formula to specify the necessary separation distance, so far there is no extensive study that has been done to evaluate the suitability of the application of equation to calculate the separation distance, specifically to the safety of electrical systems integrated into the roof top of building. In this study, a new computational method has been developed for calculation of the separation distance between an LPS and metallic components on the roof. In the proposed method which is based on the theoretical background of the IEC62305-3 Standard formula, the break down behavior of the gap geometry between the LPS and the metallic components for the applied voltage across the gap is analyzed. PSCAD software was used to model the LPS and the lightning strokes.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Separation distances in lightning protection of structures
    Sowa, Andrzej
    PRZEGLAD ELEKTROTECHNICZNY, 2010, 86 (11B): : 86 - 89
  • [2] An integrated lightning protection system
    Lanzoni, JA
    ISA 2002 TECHNOLOGY UPDATE, VOL LVII, PT 1, 2002, 422 : 517 - 526
  • [3] Differences between integrated and non-integrated plans in Medicare Advantage
    Park, Sungchul
    Langellier, Brent A.
    Meyers, David J.
    HEALTH SERVICES RESEARCH, 2023, 58 (03) : 560 - 568
  • [4] Influence of Lightning Current Waveshape on the Separation Distance Required between Electrical Equipment and Lightning Protection System
    Markowska, R.
    ELEKTRONIKA IR ELEKTROTECHNIKA, 2013, 19 (04) : 15 - 18
  • [5] COST OF CAPITAL AND TAXES IN A NON-INTEGRATED TAX SYSTEM AND IN ONE INTEGRATED
    Nino T, Jorge
    Zurita L, Salvador
    Castillo R, Augusto
    TRIMESTRE ECONOMICO, 2014, 81 (321): : 109 - 132
  • [6] LIGHTNING HAZARD OF STRUCTURES AND PROTECTION SYSTEM EFFICIENCY
    MAZZETTI, C
    POMPILI, M
    FLISOWSKI, Z
    NUCCI, CA
    CONFERENCE RECORD OF THE 1989 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING, PTS 1-2, 1989, : 1880 - 1885
  • [7] Building Integrated Lightning Protection Technology and System Design
    Feng, Xianjie
    PROCEEDINGS OF THE 2016 4TH INTERNATIONAL CONFERENCE ON MACHINERY, MATERIALS AND INFORMATION TECHNOLOGY APPLICATIONS, 2016, 71 : 1272 - 1277
  • [8] The determinants of the decisions between integrated and non-integrated audits from the perspective of corporate governance
    Yin, Meiqun
    Wang, Liyang
    Zhang, Jidong
    Han, Jing
    INTERNATIONAL JOURNAL OF DISCLOSURE AND GOVERNANCE, 2024, 21 (02) : 241 - 251
  • [9] Variation of Minimum Safety Separation for Non-Conducting Lightning Targets
    Nourirad, Ghasem
    Izadi, Mahdi
    Gomes, Chandima
    Ab Kadir, Mohd Zainal Abidin
    2014 INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2014, : 1520 - 1523
  • [10] The Proposition to Safety of a Lightning Protection System for High Structures
    Tarimer, Ilhan
    Kuca, Boleslaw
    TEM JOURNAL-TECHNOLOGY EDUCATION MANAGEMENT INFORMATICS, 2013, 2 (04): : 309 - 313