Wearable Monitoring Devices for Biomechanical Risk Assessment at Work: Current Status and Future ChallengesA Systematic Review

被引:88
|
作者
Alberto, Ranavolo [1 ]
Draicchio, Francesco [1 ]
Varrecchia, Tiwana [2 ]
Silvetti, Alessio [1 ]
Iavicoli, Sergio [1 ]
机构
[1] INAIL, Dept Occupat & Environm Med Epidemiol & Hyg, Via Fontana Candida 1, I-00078 Rome, Italy
[2] Roma TRE Univ, Dept Engn, Via Vito Volterra 62, I-00146 Rome, Italy
关键词
standardized biomechanical risk assessment methods; instrumental-based biomechanical risk assessment; wearable sensors; sEMG; IMUs; hand-held dynamometers; grip force sensors; FIBER CONDUCTION-VELOCITY; HAND-HELD DYNAMOMETRY; LOW-BACK-PAIN; MUSCLE ACTIVATION INTERVALS; NIOSH LIFTING EQUATION; UPPER TRAPEZIUS MUSCLE; REPETITIVE ARM WORK; MUSCULOSKELETAL DISORDERS; SURFACE EMG; COACTIVATION INDEX;
D O I
10.3390/ijerph15092001
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Background: In order to reduce the risk of work-related musculoskeletal disorders (WMSDs) several methods have been developed, accepted by the international literature and used in the workplace. The purpose of this systematic review was to describe recent implementations of wearable sensors for quantitative instrumental-based biomechanical risk assessments in prevention of WMSDs. Methods: Articles written until 7 May 2018 were selected from PubMed, Scopus, Google Scholar and Web of Science using specific keywords. Results: Instrumental approaches based on inertial measurement units and sEMG sensors have been used for direct evaluations to classify lifting tasks into low and high risk categories. Wearable sensors have also been used for direct instrumental evaluations in handling of low loads at high frequency activities by using the local myoelectric manifestation of muscle fatigue estimation. In the field of the rating of standard methods, on-body wireless sensors network-based approaches for real-time ergonomic assessment in industrial manufacturing have been proposed. Conclusions: Few studies foresee the use of wearable technologies for biomechanical risk assessment although the requirement to obtain increasingly quantitative evaluations, the recent miniaturization process and the need to follow a constantly evolving manual handling scenario is prompting their use.
引用
收藏
页数:26
相关论文
共 50 条
  • [1] Wearable Monitoring Devices for Biomechanical Risk Assessment at Work: Current Status and Future Challenges-A Systematic Review (vol 15, 2001, 2018)
    Ranavolo, Alberto
    Draicchio, Francesco
    Varrecchia, Tiwana
    Silvetti, Alessio
    Iavicoli, Sergio
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2018, 15 (11)
  • [2] Current devices and Future Perspectives on Neuromuscular Blockade Monitoring: A Systematic Review
    Torneiro, Andre
    Oliveira, Eva
    Rodrigues, Nuno F.
    2023 IEEE 11TH INTERNATIONAL CONFERENCE ON SERIOUS GAMES AND APPLICATIONS FOR HEALTH, SEGAH, 2023,
  • [3] Monitoring sarcopenia with wearable devices: a systematic review protocol
    Pimentel, Marcela Monteiro
    dos Santos, Whitney Houston Barbosa
    Rodrigues, Eujessika Katielly
    Fernandes, Sabrina Gabrielle Gomes
    de Carvalho, Polyagna Ferreira
    Fernandes, Ana Tereza do Nascimento Sales Figueiredo
    Barbosa, Paulo Eduardo e Silva
    Maciel, Alvaro Campos Cavalcanti
    BMJ OPEN, 2023, 13 (06):
  • [4] Evaluation of Wearable Sensor Devices in Parkinson's Disease: A Review of Current Status and Future Prospects
    Lu, Ruirui
    Xu, Yan
    Li, Xiaohui
    Fan, Yongli
    Zeng, Weiqi
    Tan, Yang
    Ren, Kang
    Chen, Wenwu
    Cao, Xuebing
    PARKINSONS DISEASE, 2020, 2020
  • [5] Wearable Devices for Environmental Monitoring in the Built Environment: A Systematic Review
    Salamone, Francesco
    Masullo, Massimiliano
    Sibilio, Sergio
    SENSORS, 2021, 21 (14)
  • [6] Effects of Wearable Devices with Biofeedback on Biomechanical Performance of Running-A Systematic Review
    Giraldo-Pedroza, Alexandra
    Lee, Winson Chiu-Chun
    Lam, Wing-Kai
    Coman, Robyn
    Alici, Gursel
    SENSORS, 2020, 20 (22) : 1 - 25
  • [7] Current Evidence for Continuous Vital Signs Monitoring by Wearable Wireless Devices in Hospitalized Adults: Systematic Review
    Leenen, Jobbe P. L.
    Leerentveld, Crista
    van Dijk, Joris D.
    van Westreenen, Henderik L.
    Schoonhoven, Lisette
    Patijn, Gijsbert A.
    JOURNAL OF MEDICAL INTERNET RESEARCH, 2020, 22 (06)
  • [8] A Comprehensive Review on Water Quality Monitoring Devices: Materials Advances, Current Status, and Future Perspective
    Thakur, Anupma
    Devi, Pooja
    CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2024, 54 (02) : 193 - 218
  • [9] Current Status and Future Prospects for the Assessment of Marine and Coastal Ecosystem Services: A Systematic Review
    Liquete, Camino
    Piroddi, Chiara
    Drakou, Evangelia G.
    Gurney, Leigh
    Katsanevakis, Stelios
    Charef, Aymen
    Egoh, Benis
    PLOS ONE, 2013, 8 (07):
  • [10] Wearable electronic devices for chronic pain intensity assessment: A systematic review
    Avila, Francisco R.
    McLeod, Christopher J.
    Huayllani, Maria T.
    Boczar, Daniel
    Giardi, Davide
    Bruce, Charles J.
    Carter, Rickey E.
    Forte, Antonio J.
    PAIN PRACTICE, 2021, 21 (08) : 955 - 965