Harmonising measurements of 8-oxo-7,8-dihydro-2′-deoxyguanosine in cellular DNA and urine

被引:42
|
作者
Moller, Peter [1 ]
Cooke, Marcus S. [2 ,3 ]
Collins, Andrew [4 ]
Olinski, Ryszard [5 ]
Rozalski, Rafal [5 ]
Loft, Steffen [1 ]
机构
[1] Univ Copenhagen, Environm Hlth Sect, Dept Publ Hlth, Post Box 2099,Oster Farimagsgade 5A, DK-1014 Copenhagen K, Denmark
[2] Univ Leicester, Oxidat Stress Grp, Dept Canc Studies, Leicester LE1 7RH, Leics, England
[3] Univ Leicester, Oxidat Stress Grp, Dept Genet, Leicester LE1 7RH, Leics, England
[4] Univ Oslo, Dept Nutr, N-0316 Oslo, Norway
[5] Nicolaus Copernicus Univ, Coll Med Bydgoszcz, Dept Clin Biochem, Karlowicza 24, Poland
关键词
8-oxodGuo; biomarker; comet assay; DNA damage; validation; urine; oxidative stress; PERFORMANCE LIQUID-CHROMATOGRAPHY; OXIDATIVELY DAMAGED DNA; HPLC-ELECTROCHEMICAL DETECTION; TANDEM MASS-SPECTROMETRY; COMET ASSAY; QUANTITATIVE-DETERMINATION; SCORING EXERCISE; NUCLEAR-DNA; IN-VIVO; LESIONS;
D O I
10.3109/10715762.2011.644241
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Levels of oxidatively damaged cellular DNA and urinary excretion of damaged 2'-deoxyribonuclosides are widely measured in biomonitoring studies examining the role of oxidative stress induced by environmental exposures, lifestyle factors and development of disease. This has promoted efforts to harmonise measurements of oxidised guanine nucleobases by the variety of analytical approaches for DNA and urinary levels of damage, in multi-laboratory trials that are centred in Europe. The large inter-laboratory variation reported of values of oxidatively damaged DNA is reduced by harmonising assay protocols. Recent attention on optimal conditions for the comet assay may lead to better understanding of the most critical steps in procedure, which generate variation in DNA damage levels between laboratories. Measurements of urinary excretion of oxidatively generated 8-oxo-7,8-dihydro-2'-deoxyguanosine also show large differences between different methods, where chromatographic techniques generally show more reliable results than antibody-based methods. In this case, standardising calibrants is aimed at improving within technique agreement.
引用
收藏
页码:541 / 553
页数:13
相关论文
共 50 条
  • [1] Measurement of 8-oxo-7,8-dihydro-2′-deoxyguanosine in urine by an improved ELISA
    Rossner, Pavel, Jr.
    Orhan, Hilmi
    Koppen, Gudrun
    Sakai, Kazuo
    Santella, Regina M.
    Ambroz, Antonin
    Rossnerova, Andrea
    Sram, Radim J.
    Ciganek, Miroslav
    Neca, Jiri
    Arzuk, Ege
    Mutlu, Neliye
    Cooke, Marcus S.
    [J]. TOXICOLOGY LETTERS, 2017, 280 : S52 - S52
  • [2] Comparison of the mutagenic properties of 8-oxo-7,8-dihydro-2′-deoxyadenosine and 8-oxo-7,8-dihydro-2′-deoxyguanosine DNA lesions in mammalian cells
    Tan, XZ
    Grollman, AP
    Shibutani, S
    [J]. CARCINOGENESIS, 1999, 20 (12) : 2287 - 2292
  • [3] Chromatographic determination of 8-oxo-7,8-dihydro-2′-deoxyguanosine in cellular DNA:: A validation study
    Duez, P
    Helson, M
    Some, TI
    Dubois, J
    Hanocq, M
    [J]. FREE RADICAL RESEARCH, 2000, 33 (03) : 243 - 260
  • [4] Radical Chemistry of 8-Oxo-7,8-dihydro-2′-deoxyadenosine and 8-Oxo-7,8-dihydro-2′-deoxyguanosine: A Pulse Radiolysis Study
    Singh, Thounaojam Avinash
    Rao, B. S. Madhava
    O'Neill, Peter
    [J]. JOURNAL OF PHYSICAL CHEMISTRY B, 2010, 114 (49): : 16611 - 16617
  • [5] Commentary on: Is preheat necessary for the measurement of 8-oxo-7,8-dihydroguanosine and 8-oxo-7,8-dihydro-2′-deoxyguanosine in urine samples
    Hu, Chiung-Wen
    Cooke, Marcus S.
    Wang, Yi-Jhen
    Chao, Mu-Rong
    [J]. JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2023, 37 (06)
  • [6] 8-Oxo-7,8-dihydroguanine and 8-oxo-7,8-dihydro-2′-deoxyguanosine levels in human urine do not depend on diet
    Gackowski, D
    Rozalski, R
    Roszkowski, K
    Jawien, A
    Foksinski, M
    Olinski, R
    [J]. FREE RADICAL RESEARCH, 2001, 35 (06) : 825 - 832
  • [7] Aging and defense against generation of 8-oxo-7,8-dihydro-2′-deoxyguanosine in DNA
    Mikkelsen, Lone
    Bialkowski, Karol
    Risom, Lotte
    Lohr, Mille
    Loft, Steffen
    Moller, Peter
    [J]. FREE RADICAL BIOLOGY AND MEDICINE, 2009, 47 (05) : 608 - 615
  • [8] Is pre-heat necessary for the measurement of 8-oxo-7,8-dihydroguanosine and 8-oxo-7,8-dihydro-2′-deoxyguanosine in urine samples
    Zou, Yutong
    Ma, Xiaoli
    Yu, Songlin
    Qiu, Ling
    [J]. JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2022, 36 (10)
  • [9] Evidence for attenuated cellular 8-oxo-7,8-dihydro-2′-deoxyguanosine removal in cancer patients
    Cooke, MS
    Rozalski, R
    Dove, R
    Gackowski, D
    Siomek, A
    Evans, MD
    Olinski, R
    [J]. BIOLOGICAL CHEMISTRY, 2006, 387 (04) : 393 - 400
  • [10] Inter-laboratory validation of procedures for measuring 8-oxo-7,8-dihydroguanine/8-oxo-7,8-dihydro-2′-deoxyguanosine in DNA
    Collins, AR
    Gedik, C
    Wood, S
    White, A
    Dubois, J
    Duez, P
    Rees, JF
    Legall, R
    Degand, L
    Loft, S
    Jensen, A
    Poulsen, H
    Weimann, A
    Jensen, BR
    Cadet, J
    Douki, T
    Ravanat, JL
    Faure, H
    Tripier, M
    Morel, I
    Sergent, O
    Cillard, P
    Morin, B
    Epe, B
    Phoa, N
    Hartwig, A
    Pelzer, A
    Dolara, P
    Casalini, C
    Guglielmi, F
    Luceri, C
    Kasai, H
    Kido, R
    Olinski, R
    Bialkowski, K
    Duracková, Z
    Hlinciková, L
    Korytar, P
    Dusinská, M
    Mislanová, C
    Viña, J
    Lloret, A
    Möller, L
    Hofer, T
    Gremaud, E
    Fay, L
    Stadler, R
    Eakins, J
    Pognan, F
    O'Brien, J
    [J]. FREE RADICAL RESEARCH, 2002, 36 (03) : 239 - 245