Single source-based energy and efficiency calibration method for the assessment of an alpha imaging detector

被引:0
|
作者
Kim, G. [1 ]
Lim, I. [1 ]
Kim, B. [1 ]
Song, K. [1 ]
Kim, J. -G. [1 ]
机构
[1] Korea Inst Radiol & Med, 75 Nowon Ro, Seoul 01812, South Korea
来源
JOURNAL OF INSTRUMENTATION | 2021年 / 16卷 / 12期
基金
新加坡国家研究基金会;
关键词
Detector alignment and calibration methods (lasers; sources; particle-beams); Detector design and construction technologies and materials;
D O I
10.1088/1748-0221/16/12/C12017
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An alpha imaging detector acquires a two-dimensional distribution of a sample that emits alpha particles. For the quantitative analysis of the image of an alpha-emitting sample, the individual energies of the alpha particles must be identified, which can be achieved using the spectrometric method after detector calibration. In this study, an energy and efficiency calibration method was investigated to assess an alpha imaging detector. The calibration was performed using a single standard source of Am-241 based on the energy loss characteristic of an alpha particle. The feasibility of the calibration method was evaluated using another source, Ac-225. The calibrated alpha imaging detector was evaluated in terms of energy resolution and detection efficiency, and the alpha imaging detector was found to be efficiently calibrated using a single standard source. The calibrated alpha imaging detector appears promising for the quantitative analysis of samples that emit alpha particles.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Efficiency calibration of an HPGe detector in the 0.1–2.5 MeV energy range for Am-Be neutron source-based PGAA applications
    Ş. Turhan
    Journal of Radioanalytical and Nuclear Chemistry, 2007, 273 : 443 - 450
  • [2] Efficiency calibration of an HPGe detector in the 0.1-2.5 MeV energy range for Am-Be neutron source-based PGAA applications
    Turhan, S.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2007, 273 (02) : 443 - 450
  • [3] Results from source-based and detector-based calibrations of a CLARREO Calibration Demonstration System
    Angal, Amit
    McCorkel, Joel
    Thome, Kurt
    EARTH OBSERVING SYSTEMS XXI, 2016, 9972
  • [4] Source-based software risk assessment
    van Deursen, A
    Kuipers, T
    INTERNATIONAL CONFERENCE ON SOFTWARE MAINTENANCE, PROCEEDINGS, 2003, : 385 - 388
  • [5] Interference source-based quality assessment method for postauricular photoplethysmography signals
    Qi, Yusheng
    Zhang, Aihua
    Ma, Yurun
    Wang, Huidong
    Li, Jiaqi
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2023, 84
  • [6] Calibration of a single hexagonal NaI(Tl) detector using a new numerical method based on the efficiency transfer method
    Abbas, Mahmoud I.
    Badawi, M. S.
    Ruskov, I. N.
    El-Khatib, A. M.
    Grozdanov, D. N.
    Thabet, A. A.
    Kopatch, Yu. N.
    Gouda, M. M.
    Skoy, V. R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 771 : 110 - 114
  • [7] MODIFIED METHOD FOR EFFICIENCY CALIBRATION OF HIGH-ENERGY GAMMA-DETECTOR
    YE, ZY
    LI, YB
    DING, SY
    BAO, ZY
    YANG, XY
    RONG, CF
    DING, XX
    ZHENG, JM
    CHINESE PHYSICS LETTERS, 1994, 11 (01) : 12 - 15
  • [8] Source-based calibration of space instruments using calculable synchrotron radiation
    Klein, Roman
    Fliegauf, Rolf
    Kroth, Simone
    Paustian, Wolfgang
    Reichel, Thomas
    Richter, Mathias
    Thornagel, Reiner
    JOURNAL OF ASTRONOMICAL TELESCOPES INSTRUMENTS AND SYSTEMS, 2016, 2 (04)
  • [9] Neutron source-based event reconstruction in the JUNO detector<bold> </bold>
    Takenaka, Akira
    XVIII INTERNATIONAL CONFERENCE ON TOPICS IN ASTROPARTICLE AND UNDERGROUND PHYSICS, 2024,
  • [10] EFFICIENCY CALIBRATION OF A GE(LI) DETECTOR AT SHORT SOURCE-TO-DETECTOR DISTANCE
    KAWADE, K
    EZUKA, M
    YAMAMOTO, H
    SUGIOKA, K
    KATOH, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1981, 190 (01): : 101 - 106