Investigations on an improved transmission line for THz DNP-NMR spectroscopy

被引:1
|
作者
Cao Yi-Chao [1 ]
Chen Qiang [1 ]
Zhang Chen [1 ]
Song Tao [1 ]
Huang Jie [1 ]
Hu Qiao [1 ]
Liu Di-Wei [1 ]
Wang Wei [1 ]
Hu Min [1 ]
Zhong Ren-Bin [1 ]
Shen Hao [1 ]
机构
[1] Univ Elect Sci & Technol China, Sch Elect Sci & Engn, Chengdu 610054, Sichuan, Peoples R China
关键词
transmission line; phase-correcting mirror; nuclear magnetic resonance; dynamic nuclear polarization; DYNAMIC NUCLEAR-POLARIZATION; GHZ;
D O I
10.11972/j.issn.1001-9014.2019.06.002
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The improved transmission and mirror system for a 263 GHz DNP-NMR spectrometer has been designed and numerically simulated based on the geometric optics theory and the vector diffraction theory. The system includes two corrugated waveguides , a parabolic mirror and an angle-adjustable phase-correcting mirror. The simulation results show that a well-focused Gaussian-like output wave-beam with 99.90% scalar Gaussian mode content. 99. 55% vector Gaussian mode content has been obtained. The direction of the output beam can be changed by only adjusting the angle of the phase-correcting mirror to match the DNP-NMR sample. The scalar Gaussian mode content is about 99. 57%, and the vector Gaussian mode content is about 98. 97% when the direction of the output beam changes in +/- 15 degrees.
引用
收藏
页码:690 / 694
页数:5
相关论文
共 22 条
  • [1] High-resolution proton-detected NMR of proteins at very fast MAS
    Andreas, Loren B.
    Le Marchand, Tanguy
    Jaudzems, Kristaps
    Pintacuda, Guido
    [J]. JOURNAL OF MAGNETIC RESONANCE, 2015, 253 : 36 - 49
  • [2] Active polymers containing Lactobacillus curvatus CRL705 bacteriocins: Effectiveness assessment in Wieners
    Blanco Massani, M.
    Molina, V.
    Sanchez, M.
    Renaud, V.
    Eisenberg, P.
    Vignolo, G.
    [J]. INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY, 2014, 178 : 7 - 12
  • [3] Applications of NMR spectroscopy to systems biochemistry
    Fan, Teresa W. -M.
    Lane, Andrew N.
    [J]. PROGRESS IN NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY, 2016, 92-93 : 18 - 53
  • [4] GOLDSMITH PF, 1998, QUASIOPTICAL SYSTEMS, pCH2
  • [5] Polarization-enhanced NMR spectroscopy of biomolecules in frozen solution
    Hall, DA
    Maus, DC
    Gerfen, GJ
    Inati, SJ
    Becerra, LR
    Dahlquist, FW
    Griffin, RG
    [J]. SCIENCE, 1997, 276 (5314) : 930 - 932
  • [6] Second harmonic operation at 460 GHz and broadband continuous frequency tuning of a gyrotron oscillator
    Hornstein, MK
    Bajaj, VS
    Griffin, RG
    Kreischer, KE
    Mastovsky, I
    Shapiro, MA
    Sirigiri, JR
    Temkin, RJ
    [J]. IEEE TRANSACTIONS ON ELECTRON DEVICES, 2005, 52 (05) : 798 - 807
  • [7] Development of 394.6 GHz CW gyrotron (Gyrotron FUCWII) for DNP/proton-NMR at 600 MHz
    Idehara, T.
    Ogawa, I.
    Agusu, La
    Kanemaki, T.
    Mitsudo, S.
    Saito, T.
    Fujiwara, T.
    Takahashi, H.
    [J]. INTERNATIONAL JOURNAL OF INFRARED AND MILLIMETER WAVES, 2007, 28 (06): : 433 - 442
  • [8] Continuously Frequency Tunable High Power Sub-THz Radiation Source-Gyrotron FU CW VI for 600 MHz DNP-NMR Spectroscopy
    Idehara, Toshitaka
    Kosuga, Kosuke
    Agusu, La
    Ikeda, Ryosuke
    Ogawa, Isamu
    Saito, Teruo
    Matsuki, Yoh
    Ueda, Keisuke
    Fujiwara, Toshimichi
    [J]. JOURNAL OF INFRARED MILLIMETER AND TERAHERTZ WAVES, 2010, 31 (07) : 775 - 790
  • [9] Study of a Coaxial Gyrotron Cavity With Improved Mode Selection
    Liu, Diwei
    Wang, Wei
    Qiao, Shen
    Yan, Yang
    [J]. IEEE TRANSACTIONS ON ELECTRON DEVICES, 2013, 60 (12) : 4248 - 4251
  • [10] Vector Method for Synthesis of Adapted Phase-Correcting Mirrors for Gyrotron Output Couplers
    Liu, Jianwei
    Jin, Jianbo
    Thumm, Manfred
    Jelonnek, John
    Li, Hongfu
    Zhao, Qing
    [J]. IEEE TRANSACTIONS ON PLASMA SCIENCE, 2013, 41 (09) : 2489 - 2495