A new sampler for the collection and retrieval of dry dust deposition

被引:10
|
作者
Brahney, J. [1 ]
Wetherbee, G. [2 ]
Sexstone, G. A. [3 ]
Youngbull, C. [4 ]
Strong, P. [5 ]
Heindel, R. C. [6 ,7 ]
机构
[1] Utah State Univ, Dept Watershed Sci, Logan, UT 84322 USA
[2] US Geol Survey, Hydrol Networks Branch, Denver, CO 80225 USA
[3] US Geol Survey, Colorado Water Sci Ctr, Denver, CO 80225 USA
[4] Univ Montana, Sensor Space, Flathead Lake Biol Stn, 32125 BioStn Ln, Polson, MT 59911 USA
[5] Utah State Univ, Dept Civil & Environm Engn, Logan, UT 84322 USA
[6] Univ Colorado, Inst Arctic & Alpine Res, 4001 Discovery Dr, Boulder, CO 80303 USA
[7] Kenyon Coll, Environm Studies Program, Gambier, OH 43022 USA
关键词
Dust; Aerosols; Sterile sampling; Dry deposition; NADP; WIND RIVER RANGE; AEOLIAN DUST; SAHARAN DUST; ATMOSPHERIC DEPOSITION; EOLIAN DUST; PARTICULATE MATTER; ROCKY-MOUNTAINS; SOUTHERN NEVADA; CLIMATE-CHANGE; SIERRA-NEVADA;
D O I
10.1016/j.aeolia.2020.100600
中图分类号
P9 [自然地理学];
学科分类号
0705 ; 070501 ;
摘要
Atmospheric dust can influence biogeochemical cycles, accelerate snowmelt, and affect air, water quality, and human health. Yet, the bulk of atmospherically transported material remains poorly quantified in terms of total mass fluxes and composition. This lack of information stems in part from the challenges associated with measuring dust deposition. Here we report on the design and efficacy of a new dry deposition sampler (Dry Deposition Sampling Unit (DSU)) and method that quantifies the gravitational flux of dust particles. The sampler can be used alone or within existing networks such as those employed by the National Atmospheric Deposition Program (NADP). Because the samplers are deployed sterile and the use of water to remove trapped dust is not required, this method allows for the recovery of unaltered dry material suitable for subsequent chemical and microbiological analyses. The samplers were tested in the laboratory and at 15 field sites in the western United States. With respect to material retention, sampler performance far exceeded commonly used methods. Retrieval efficiency was > 97% in all trials and the sampler effectively preserved grain size distributions during wind exposure experiments. Field tests indicated favorable comparisons to dust-on-snow measurement across sites (r(2) 0.70, p < 0.05) and within sites to co-located aerosol data (r(2) 0.57-0.99, p < 0.05). The inclusion of dust deposition and composition monitoring into existing networks increases spatial and temporal understanding of the atmospheric transport on materials and substantively furthers knowledge of the effects of dust on terrestrial ecosystems and human exposure to dust and associated deleterious compounds.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] COLLECTION EFFICIENCY OF DEPOSITION BY FILTRATING BULK SAMPLER COMPARED WITH WET DRY SAMPLER
    TAMAKI, M
    HIRAKI, T
    [J]. NIPPON KAGAKU KAISHI, 1992, (04) : 405 - 411
  • [2] PORTABLE AIR SAMPLER FOR COLLECTION OF RADIOACTIVE DUST
    REICH, B
    [J]. NUCLEONICS, 1953, 11 (09): : 63 - 63
  • [3] A NEW COTTON DUST SAMPLER
    PARNELL, CB
    HICKMAN, P
    MCFARLAND, A
    ARSENAULT, J
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1985, 189 (APR-): : 37 - CHAS
  • [4] A new method for evaluating dry deposition of mercury using a water surface sampler
    Sakata, M
    Marumoto, K
    [J]. JOURNAL DE PHYSIQUE IV, 2003, 107 : 1177 - 1180
  • [5] POLLUTANT SAMPLER FOR MEASUREMENTS OF ATMOSPHERIC ACIDIC DRY DEPOSITION
    KNAPP, KT
    DURHAM, JL
    ELLESTAD, TG
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1986, 20 (06) : 633 - 637
  • [6] Dust Dry Deposition over Israel
    Kishcha, Pavel
    Volpov, Evgeni
    Starobinets, Boris
    Alpert, Pinhas
    Nickovic, Slobodan
    [J]. ATMOSPHERE, 2020, 11 (02)
  • [7] Dry deposition study by using dry deposition plate and water surface sampler in Shalu, central Taiwan
    Chia-Chun Chu
    Guor-Cheng Fang
    Jhy-Cherng Chen
    I-Lin Yang
    [J]. Environmental Monitoring and Assessment, 2008, 146 : 441 - 451
  • [8] Dry deposition study by using dry deposition plate and water surface sampler in Shalu, central Taiwan
    Chu, Chia-Chun
    Fang, Guor-Cheng
    Chen, Jhy-Cherng
    Yang, I-Lin
    [J]. ENVIRONMENTAL MONITORING AND ASSESSMENT, 2008, 146 (1-3) : 441 - 451
  • [9] DUST SAMPLER WHICH SIMULATES UPPER AND LOWER LUNG DEPOSITION
    HARRIS, WB
    EISENBUD, M
    [J]. AMA ARCHIVES OF INDUSTRIAL HYGIENE AND OCCUPATIONAL MEDICINE, 1953, 8 (05): : 446 - 452
  • [10] Calibration of the MDCO dust collector and of four versions of the inverted frisbee dust deposition sampler
    Sow, Mamadou
    Goossens, Dirk
    Rajot, Jean Louis
    [J]. GEOMORPHOLOGY, 2006, 82 (3-4) : 360 - 375