Endothelial cell response to biomechanical forces under simulated vascular loading conditions

被引:31
|
作者
Punchard, M. A.
Stenson-Cox, C.
O'Cearbhaill, E. D.
Lyons, E.
Gundy, S.
Murphy, L.
Pandit, A.
McHugh, P. E.
Barron, V.
机构
[1] Natl Univ Ireland Univ Coll Galway, Natl Ctr Biomed Engn Sci, Galway, Ireland
[2] Natl Univ Ireland Univ Coll Galway, Dept Biomed & Mech Engn, Galway, Ireland
基金
爱尔兰科学基金会;
关键词
physiological simulator; endothelial cells; cell morphology; cell orientation; gene expression;
D O I
10.1016/j.jbiomech.2007.03.029
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In vivo, endothelial cells (EC) are constantly exposed to the haemodynamic forces (HF) of pressure, wall shear stress and hoop stress. The main aim of this study was to design, create and validate a novel perfusion bioreactor capable of delivering shear stress and intravascular pressure to EC it? vitro and to characterise their morphology, orientation and gene expression. Here we report the creation and validation of such a simulator and the dual application of pressure (120/60 mmHg) and low shear stress (5 dyn/cm(2)) to a monolayer of EC established on a non-compliant silicone tube. Under these conditions, EC elongated and realigned obliquely to the direction of applied shear stress in a time-dependent manner. Furthermore, randomly distributed F-actin microfilaments reorganised into long, dense stress fibres crossing the cells in a direction perpendicular to that of flow. Finally, combinatorial biomechanical conditioning of EC induced the expression of the inflammatory-associated E-selectin gene. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3146 / 3154
页数:9
相关论文
共 50 条
  • [1] Endothelial Cell Responses to Biomechanical Forces in Lymphatic Vessels
    Sabine, Amelie
    Demir, Cansaran Saygili
    Petrova, Tatiana V.
    ANTIOXIDANTS & REDOX SIGNALING, 2016, 25 (07) : 451 - 465
  • [3] A Biomechanical Evaluation of Femoroplasty Under Simulated Fall Conditions
    Sutter, Edward G.
    Mears, Simon C.
    Belkoff, Stephen M.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2010, 24 (02) : 95 - 99
  • [4] Vascular Endothelial Growth Factor Release from Alginate Microspheres Under Simulated Physiological Compressive Loading and the Effect on Human Vascular Endothelial Cells
    Li, Qiang
    Hou, Tianyong
    Zhao, Jianning
    Xu, Jianzhong
    TISSUE ENGINEERING PART A, 2011, 17 (13-14) : 1777 - 1785
  • [5] In Situ Forces in the Anteromedial and Posterolateral Bundles of the Anterior Cruciate Ligament Under Simulated Functional Loading Conditions
    Wu, Jia-Lin
    Seon, Jong Keun
    Gadikota, Hemanth R.
    Hosseini, Ali
    Sutton, Karen M.
    Gill, Thomas J.
    Li, Guoan
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2010, 38 (03): : 558 - 563
  • [6] Role of Biomechanical Forces in Stem Cell Vascular Lineage Differentiation
    Potter, Claire M. F.
    Lao, Ka Hou
    Zeng, Lingfang
    Xu, Qingbo
    ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 2014, 34 (10) : 2184 - 2190
  • [7] Biomechanical Response of Ribs Under Quasistatic Frontal Loading
    Kindig, Matthew
    Lau, Anthony G.
    Kent, Richard W.
    TRAFFIC INJURY PREVENTION, 2011, 12 (04) : 377 - 387
  • [8] Performance of roof fasteners under simulated loading conditions
    Baskaran, A
    Dutt, O
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1997, 72 (1-3) : 389 - 400
  • [9] Simulated biomechanical performance of morphologically disparate ant mandibles under bite loading
    Klunk, C. L.
    Argenta, M. A.
    Rosumek, F. B.
    Schmelzle, S.
    van de Kamp, T.
    Hammel, J. U.
    Pie, M. R.
    Heethoff, M.
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [10] Simulated biomechanical performance of morphologically disparate ant mandibles under bite loading
    C. L. Klunk
    M. A. Argenta
    F. B. Rosumek
    S. Schmelzle
    T. van de Kamp
    J. U. Hammel
    M. R. Pie
    M. Heethoff
    Scientific Reports, 13