Condensation flow at the wet steam centrifugal turbine stage

被引:2
|
作者
Liu, Yaping [1 ,2 ]
Du, Xuefei [1 ,2 ]
Shi, Xuyang [1 ,2 ]
Huang, Diangui [1 ,2 ]
机构
[1] Univ Shanghai Sci & Technol, Sch Energy & Power Engn, Shanghai, Peoples R China
[2] Shanghai Key Lab Power Energy Multiphase Flow & H, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
Centrifugal turbine; wet steam; nonequilibrium condensation; superheating degree; CONDENSING STEAM; LAST STAGE; NONEQUILIBRIUM CONDENSATION; DEVIATION ANGLE; PRESSURE; LOSSES; FIELD; PERFORMANCE; CASCADE; NOZZLE;
D O I
10.1177/0957650919894823
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper investigates spontaneous condensation of wet steam in a centrifugal turbine by means of three-dimensional computational fluid dynamics. The flow field and aerodynamic characteristics of the wet steam in the centrifugal turbine are compared and analyzed by using the equilibrium steam and nonequilibrium steam models, respectively, where the latter applies the classical droplet nucleation theory and neglects velocity slip between the liquid phase and the gaseous phase. The state parameters of wet steam are described here based on the IAPWS'97 formulation. It is concluded that under the design condition, the mass flow rate, wetness fraction, and flow angle of the wet steam centrifugal turbine in the nonequilibrium steam model all change compared with the equilibrium steam model, with values of 4.4%, 0.5%, and 10.57%, respectively. Then the performance variation of the wet steam centrifugal turbine is analyzed under different steam conditions and different outlet back-pressure conditions. The results show that the change law of the mass flow rate, shaft power, and wetness fraction in the centrifugal turbine are basically identical in both models, and the mass flow rate, shaft power, wheel efficiency, and entropy loss coefficient of the centrifugal turbine in the nonequilibrium steam model are all higher than those in the equilibrium steam model, whereas the outlet wetness fraction is lower than that in the equilibrium steam model.
引用
收藏
页码:1108 / 1121
页数:14
相关论文
共 50 条
  • [1] Numerical simulation of wet steam transonic condensation flow in the last stage of a steam turbine
    Han, Xu
    Han, Zhonghe
    Zeng, Wei
    Li, Peng
    Qian, Jiangbo
    INTERNATIONAL JOURNAL OF NUMERICAL METHODS FOR HEAT & FLUID FLOW, 2018, 28 (10) : 2378 - 2403
  • [2] Research on wet steam condensation flow characteristics of steam turbine last stage under zero output condition
    Han, Xu
    Zhu, Qiuliang
    Guan, Jiandong
    Han, Zhonghe
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2022, 179
  • [3] Wet steam flow and condensation loss in turbine blade cascades
    Wen, Chuang
    Yang, Yan
    Ding, Hongbing
    Sun, Chunqian
    Yan, Yuying
    APPLIED THERMAL ENGINEERING, 2021, 189
  • [5] 2D-simulation of wet steam flow in a steam turbine with spontaneous condensation
    Sun L.-X.
    Zheng Q.
    Liu S.-L.
    Journal of Marine Science and Application, 2007, 6 (2) : 59 - 63
  • [6] Effect of Steam Condensation on Flow Characteristics in a Turbine Stage.
    Filippov, G.A.
    Seleznev, L.I.
    Gordeeva, I.V.
    Energomashinostroenie, 1976, (06): : 21 - 23
  • [7] Unsteady non-equilibrium condensation flow of 3-D wet steam stage of steam turbine with mesh method
    Ding, Hongbing
    Zhang, Yu
    Sun, Chunqian
    Lakzian, Esmail
    Wen, Chuang
    Wang, Chao
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2022, 179
  • [8] Non-equilibrium condensation flow characteristics of wet steam considering condensation shock effect in the steam turbine
    Hu, Pengfei
    Hou, Tianbo
    Gu, Weifei
    Wan, Jie
    Li, Qi
    Applied Thermal Engineering, 2025, 259
  • [9] Design and Aerodynamic Analysis of a Two-stage Transonic Wet Steam Centrifugal Turbine
    Huang, Dian-Gui (dghuang@usst.edu.cn), 1600, Science Press (41):
  • [10] Wet Steam Nonequilibrium Condensation Flow-Induced Vibrations of a Nuclear Turbine Blade
    Guo, Bing
    Tang, Weixiao
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2018, 140 (11):