PURPOSE: Our purpose was to evaluate intraaneurysmal blood velocity by using time-density curve analysis and digital subtraction angiography. METHODS: In 31 aneurysms, aneurysmal blood velocity was examined,vith digital subtraction angiography to determine mean transit time (MTT), peak density time (time to peak opacification) (PDT), and time to half-peak opacification (T1/2). Thirty frames per second were acquired, and the time-density curve was calculated. Regions of interest were drawn on the proximal parent artery, on the distal parent artery, and on the aneurysm itself. RESULTS: There was no significant difference in MTT of blood velocity in the proximal site on the parent artery, in the distal site on the parent artery, and in the aneurysm. Similarly, there was no significant difference ire PDT in the parent artery, in the distal site on the parent artery, and in the aneurysm; nor was there a significant difference in T1/2 in the parent artery, in the distal site on the parent artery, and in the aneurysm; that is, intraaneurysmal blood velocity was similar to that in the parent artery, PDT and T1/2 of small aneurysms were faster than that of large aneurysms; that is, blood velocity of small aneurysms was faster than that of large aneurysms. CONCLUSION: Intraaneurysmal blood velocity in small aneurysms is similar to that in the parent artery; consequently, the central stream probably reaches the aneurysmal wall, Intraaneurysmal blood velocity in large aneurysms appears to be somewhat slower than that in small aneurysms.
引用
收藏
页码:1303 / 1307
页数:5
相关论文
共 50 条
  • [1] Denoising of time-density data in digital subtraction angiography
    Bogunovic, H
    Loncaric, S
    IMAGE ANALYSIS, PROCEEDINGS, 2005, 3540 : 1157 - 1166
  • [2] EVALUATION OF PANCREATIC MORPHOLOGY BY DIGITAL SUBTRACTION ENDOSCOPIC RETROGRADE PANCREATOGRAPHY AND ITS TIME-DENSITY CURVE
    ARAKAWA, S
    UENO, F
    IWAMURA, K
    GASTROINTESTINAL ENDOSCOPY, 1987, 33 (02) : 156 - 156
  • [3] Drawing time-density curve with Fiji/ImageJ: An alternative approach for parametric coding of cerebral digital subtraction angiography
    Zhao, Zhongyu
    Liang, Wenzhao
    Zhao, Bingyang
    Zhang, Kai
    Wang, Lingling
    Mang, Jing
    JOURNAL OF NEUROSCIENCE METHODS, 2023, 399
  • [4] Evaluation of intra-aneurysmal blood flow by time density curve using digital subtraction angiography
    Tenjin, H
    Asakura, F
    Nakahara, Y
    Matsumoto, K
    Matsuo, T
    Urano, F
    Ueda, S
    STROKE, 1998, 29 (01) : 311 - 311
  • [5] The peak time difference of time-density curve in intravenous digital subtraction angiography correlates to an asymmetric cerebral blood flow as determined by positron emission tomography
    Imamura, T
    Nagasawa, H
    Itoh, M
    Tsuburaya, K
    EUROPEAN JOURNAL OF NEUROLOGY, 1996, 3 (03) : 227 - 231
  • [6] Intra-arterial administration of fasudil hydrochloride for vasospasm following subarachnoid hemorrhage - Analysis of time-density curve with digital subtraction angiography
    Iwabuchi, Satoshi
    Yokouchi, Tetsuya
    Hayashi, Morito
    Uehara, Hideo
    Ueda, Morikazu
    Samejima, Hirotsugu
    NEUROLOGIA MEDICO-CHIRURGICA, 2006, 46 (11) : 535 - 539
  • [7] Correlation Between Contrast Time-Density Time on Digital Subtraction Angiography and Flow: An in Vitro Study
    Brunozzi, Denise
    Shakur, Sophia F.
    Ismail, Rahim
    Linninger, Andreas
    Hsu, Chih-Yang
    Charbel, Fady T.
    Alaraj, Ali
    WORLD NEUROSURGERY, 2018, 110 : E315 - E320
  • [8] Intra-arterial administration of fasudil hydrochloride for vasospasm following subarachnoid hemorrhage - Analysis of time-density curve with digital subtraction angiography - Commentary
    Zhou, Liang-Fu
    NEUROLOGIA MEDICO-CHIRURGICA, 2006, 46 (11) : 540 - 540
  • [9] TIME DENSITY CURVE OF INTRAVENOUS DIGITAL SUBTRACTION ANGIOGRAPHY IN MOYAMOYA DISEASE
    HIRATA, Y
    NONAKA, N
    MIURA, G
    YOSHIOKA, S
    MATSUKADO, Y
    NEURORADIOLOGY, 1987, 29 (06) : 602 - 602
  • [10] Contrast Time-Density Time on Digital Subtraction Angiography Correlates With Cerebral Arteriovenous Malformation Flow Measured by Quantitative Magnetic Resonance Angiography, Angioarchitecture, and Hemorrhage
    Brunozzi, Denise
    Hussein, Ahmed E.
    Shakur, Sophia F.
    Linninger, Andreas
    Hsu, Chih-Yang
    Charbel, Fady T.
    Alaraj, Ali
    NEUROSURGERY, 2018, 83 (02) : 210 - 216