摘要
The cold end heat exchanger in a cryocooler is of highest importance for the efficient heat transfer from the applied load to the working fluid. The cooling performance of a 4 K pulse tube cooler (PTC) was greatly improved by the modification of the cold end heat exchanger. With no heat loads on the first stage, cooling capacities of 760 mW and 900 mW at 4.2 K were obtained with compressor input powers of 4.8 kW and 6.0 kW, respectively. The coefficients of performance (COP) at 4.2 K were correspondingly improved to 1.58x10(4) and 1.50x10(-4), which are comparable to those of 4 K G-M cryocoolers. A cooling capacity of 960 mW at 4.2 K was obtained with 5 W heat load on the first stage.
引用
收藏
页码:113 / 116
页数:4
相关论文
共 50 条
  • [1] The development of a pulse tube cooler with more than 1 W at 4.2 K
    Hofmann, A.
    Stautner, W.
    Pan, H.
    Crowley, D.
    Gilgrass, G.
    [J]. ADVANCES IN CRYOGENIC ENGINEERING, VOLS 51A AND B, 2006, 823 : 49 - +
  • [2] A cascade pulse tube cooler capable of energy recovery
    Wang, Longyi
    Wu, Mei
    Sun, Xiao
    Gan, Zhihua
    [J]. APPLIED ENERGY, 2016, 164 : 572 - 578
  • [3] Study of mass flow distribution between stages in a two-stage pulse tube cryocooler capable of 1.1 W at 4.2 K
    Qiu, L. M.
    Zhang, K. H.
    Dong, W. Q.
    Gan, Z. H.
    Wang, C.
    Zhang, X. J.
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2012, 35 (08): : 2332 - 2338
  • [4] 10K EM pulse tube cooler
    Jaco, C.
    Nguyen, T.
    Colbert, R.
    Raab, J.
    [J]. ADVANCES IN CRYOGENIC ENGINEERING, VOLS 53A AND 53B, 2008, 985 : 659 - 664
  • [5] Studies on the development and efficiency improvement of a 1.5 W at 25 K two stage pulse tube cooler
    Kranthi Kumar, J.
    Jacob, S.
    Karunanithi, R.
    Narasimham, G. S. V. L.
    [J]. 26TH INTERNATIONAL CRYOGENIC ENGINEERING CONFERENCE & INTERNATIONAL CRYOGENIC MATERIALS CONFERENCE 2016, 2017, 171
  • [6] Socool: A 300 K-0.3 K pulse tube/sorption cooler
    Duband, L
    Clerc, L
    Ravex, A
    [J]. ADVANCES IN CRYOGENIC ENGINEERING, VOL 47, PTS A AND B, 2002, 613 : 1233 - 1237
  • [7] Miniature pulse tube cooler
    Tward, E
    Nguyen, T
    Godden, J
    Toma, G
    [J]. ADVANCES IN CRYOGENIC ENGINEERING, VOLS. 49A AND B, 2004, 710 : 1326 - 1329
  • [8] Design of a 4K single-stage Stirling type pulse tube cooler precooled by a GM type pulse tube cooler
    Qiu, L. M.
    Li, Z. P.
    Gan, Z. H.
    Dai, L.
    [J]. CRYOGENICS AND REFRIGERATION, PROCEEDINGS, 2008, : 313 - 316
  • [9] Investigation on a thermoacoustically driven pulse tube cooler working at 82.5 K
    Qiu, Limin
    Sun, Daming
    Yan, Weilin
    Chen, Ping
    Gan, Zhihua
    Chen, Guobang
    [J]. ICEC 20: PROCEEDINGS OF THE TWENTIETH INTERNATIONAL CRYOGENIC ENGINEERING CONFERENCE, 2005, : 379 - 382
  • [10] A single-stage pulse tube cooler reached 12.6 K
    Qiu, LM
    He, YL
    Gan, ZH
    Chen, GB
    [J]. CRYOGENICS, 2005, 45 (09) : 641 - 643