Optimized optomechanical micro-cantilever array for uncooled infrared Imaging

被引:0
|
作者
Dong Feng-Liang [1 ]
Zhang Qing-Chuan [1 ]
Chen Da-Peng [2 ]
Miao Zheng-Yu [1 ]
Xiong Zhi-Ming [1 ]
Guo Zhe-Ying [1 ]
Li Chao-Bo [1 ]
Jiao Bin-Bin [1 ]
Wu Xiao-Ping [1 ]
机构
[1] Univ Sci & Technol China, Key Lab Mech Behavior & Design Mat, Hefei 230027, Peoples R China
[2] Chinese Acad Sci, Microelect R&D Ctr, Beijing, Peoples R China
关键词
D O I
10.1088/0256-307X/24/12/020
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
We present a new substrate-free bimaterial cantilever array made of SiNx and Au for an uncooled micro-optomechanical infrared imaging device. Each cantilever element has an optimized deformation magnification structure. A 160 x 160 array with a 120 mu m x 120 mu m pitch is fabricated and an optical readout is used to collectively measure deflections of all microcantilevers in the array. Thermal images of room-temperature objects with higher spatial resolution have been obtained and the noise-equivalent temperature difference of the fabricated focal plane arrays is given statistically and is measured to be about 270mK.
引用
收藏
页码:3362 / 3364
页数:3
相关论文
共 50 条
  • [1] Uncooled infrared imaging device based on optimized optomechanical micro-cantilever array
    Dong, Fengliang
    Zhang, Qingchuan
    Chen, Dapeng
    Miao, Zhengyu
    Xiong, Zhiming
    Guo, Zheying
    Li, Chaobo
    Jiao, Binbin
    Wu, Xiaoping
    [J]. ULTRAMICROSCOPY, 2008, 108 (06) : 579 - 588
  • [2] Bimaterial micro-cantilever uncooled infrared imaging system - Design and fabrication of micro-cantilever array
    Dong, Feng-Liang
    Zhang, Qing-Chuan
    Wu, Xiao-Ping
    Pan, Liang
    Guo, Zhe-Ying
    Chen, Da-Peng
    Wang, Wei-Bing
    Duan, Zhi-Hui
    [J]. Hongwai Yu Haomibo Xuebao/Journal of Infrared and Millimeter Waves, 2005, 24 (06): : 409 - 413
  • [3] Bimaterial micro-cantilever uncooled infrared imaging system-design and fabrication of micro-cantilever array
    Dong, FL
    Zhang, QC
    Wu, XP
    Pan, L
    Guo, ZY
    Chen, DP
    Wang, WB
    Duan, ZH
    [J]. JOURNAL OF INFRARED AND MILLIMETER WAVES, 2005, 24 (06) : 409 - 413
  • [4] Uncooled optically readable bimaterial micro-cantilever infrared imaging device
    Duan, ZH
    Zhang, QC
    Wu, XP
    Pan, L
    Chen, DP
    Wang, WB
    Guo, ZY
    [J]. CHINESE PHYSICS LETTERS, 2003, 20 (12) : 2130 - 2132
  • [5] Design and fabrication of micro-cantilever uncooled infrared detector
    Liu, HT
    Chen, YP
    Liang, PZ
    [J]. JOURNAL OF INFRARED AND MILLIMETER WAVES, 2006, 25 (01) : 46 - 49
  • [6] A Bulk Micromachined Cantilever Array for Uncooled Infrared Imaging
    Yi, Yuliang
    Ma, Shenglin
    Yu, Xiaomei
    Liu, Ming
    Liu, Xiaohua
    [J]. MicroNano2008-2nd International Conference on Integration and Commercialization of Micro and Nanosystems, Proceedings, 2008, : 129 - 132
  • [7] Experimental study of the effect of hydrodynamic coupling of micro-cantilever array on the dynamic response of micro-cantilever
    Institute of NanoEngineering and MicroSystems, National Tsing Hua University, No. 101, Section 2, Kuang-Fu Road, Hsinchu, Taiwan
    不详
    不详
    [J]. Sens Actuators A Phys, 1 (79-85):
  • [8] Experimental study of the effect of hydrodynamic coupling of micro-cantilever array on the dynamic response of micro-cantilever
    Lee, Jiunn-Horng
    Lau, Yung-Dong
    Yao, Chih-Min
    Fang, Weileun
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2011, 165 (01) : 79 - 85
  • [9] High-speed infrared imaging by an uncooled optomechanical focal plane array
    Feng, Yun
    Zhao, Yuejin
    Dong, Liquan
    Liu, Ming
    Li, Xueyan
    Ma, Wei
    Yu, Xiaomei
    Kong, Lingqin
    Liu, Xiaohua
    [J]. APPLIED OPTICS, 2015, 54 (34) : 10189 - 10195
  • [10] Polymeric micro-cantilever acoustic sensor array
    Xu, T
    Bachman, M
    Zeng, FG
    Li, GP
    [J]. BOSTON TRANSDUCERS'03: DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, 2003, : 1116 - 1119