Reproducibility of retinal mapping using optical coherence tomography

被引:249
|
作者
Massin, P
Vicaut, E
Haouchine, B
Erginay, A
Paques, M
Gaudric, A
机构
[1] Hop Lariboisiere, Assistance Publ Hop Paris, Dept Ophthalmol, F-75475 Paris 10, France
[2] Univ Paris, Hop Fernand Widal, Lab Etud Microcirculat, F-75252 Paris, France
关键词
D O I
10.1001/archopht.119.8.1135
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To assess the reproducibility of retinal thickness measurement using commercially available mapping software of optical coherence tomography (OCT). Methods: Six radial scans, 6 mm long and centered on the fixation point, were performed on 10 eyes of 10 healthy volunteers and 10 eyes of 10 diabetic patients with clinically significant macular edema. Retinal thickness was measured automatically using the mapping software of OCT in the 9 macular Early Treatment Diabetic Retinopathy Study areas and in a central area 500 mum in diameter. Measurement reproducibility was tested by means of 3 series of scans performed by 2 different observers on 2 different days. Results were assessed by their repeatability and intraclass correlation coefficients (ICCs). Results: In healthy subjects, intraobserver, interobserver, and intervisit reproducibility of retinal thickness measurements were excellent, with a repeatability coefficient of less than 7 mum and ICCs of greater than 0.89. In diabetic patients, the repeatability coefficient was less than 21 pm in all areas of the macula except one, with an ICC of greater than 0.98. Relative variations in measurements were small in both healthy and diabetic subjects, with reproducibilities of +/-5% and +/-6%, respectively. Conclusion: Retinal mapping software of OCT allows reproducible measurement of retinal thickness in both healthy subjects and diabetic patients with macular edema.
引用
收藏
页码:1135 / 1142
页数:8
相关论文
共 50 条
  • [1] Reproducibility of retinal thickness measurements using Optical Coherence Tomography
    Wang, RC
    Koozekanani, D
    Herderick, EE
    Roberts, C
    Katz, SE
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S125 - S125
  • [2] Reproducibility of retinal mapping program using newly developed optical coherence tomography, "NeOCT EG scanner"
    Tsuchiya, D
    Kawasaki, R
    Saito, K
    Kaneko, Y
    Hasegawa, M
    Yamashita, H
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [3] Reproducibility of retinal thickness measurements using optical coherence tomography (OCT)
    Liebmann, JM
    Baumann, M
    Gentile, RC
    DeLuca, R
    Ozols, A
    Chew, SJ
    Ritch, R
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 4464 - 4464
  • [4] Reproducibility of topographic macular thickness mapping using optical coherence tomography
    Ghanta, RK
    Schuman, JS
    Guedes, VRF
    Drexler, W
    Hertzmark, E
    Miller, VM
    MacNutt, J
    Puliafito, CA
    Fujimoto, JG
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S570 - S570
  • [5] Reproducibility of retinal thickness measurements in normal eyes using optical coherence tomography
    Baumann, M
    Gentile, RC
    Liebmann, JM
    Ritch, R
    [J]. OPHTHALMIC SURGERY AND LASERS, 1998, 29 (04): : 280 - 285
  • [6] Reproducibility of Retinal Thickness Measurements in Healthy Subjects Using Spectralis Optical Coherence Tomography
    Menke, Marcel N.
    Dabov, Simeon
    Knecht, Pascal
    Sturm, Veit
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 147 (03) : 467 - 472
  • [7] Reproducibility of Measurements of Retinal Structural Parameters Using Optical Coherence Tomography in Stargardt Disease
    Kong, Xiangrong
    Ho, Alexander
    Munoz, Beatriz
    West, Sheila
    Strauss, Rupert W.
    Jha, Anamika
    Ervin, Ann
    Buzas, Jeff
    Singh, Mandeep
    Hu, Zhihong
    Cheetham, Janet
    Ip, Michael
    Scholl, Hendrik P. N.
    [J]. TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2019, 8 (03):
  • [8] Mapping and quantifying the retinal microvasculature organization using optical coherence tomography angiography
    Ma, Yanhui
    Ohr, Matthew
    Roberts, Cynthia J.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [9] Reproducibility of macular thickness mapping on the commercial optical coherence tomography device
    MacNutt, JM
    Schuman, JS
    Guedes, VRF
    Miller, VM
    Pakter, HM
    Ghanta, RK
    Drexler, W
    Hertzmark, E
    Peiris, ID
    Puliafito, CA
    Fujimoto, JG
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S125 - S125
  • [10] Reproducibility of pachymetric mapping with high-speed optical coherence tomography
    Huang, D
    Li, Y
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U132 - U132