Serial Clinical and Angiographic Follow-Up After Phosphorylcholine-Coated Stent Implantation

被引:3
|
作者
Habara, Seiji [1 ]
Mitsudo, Kazuaki [1 ]
Kadota, Kazushige [1 ]
Goto, Tsuyoshi [1 ]
Fujii, Satoki [1 ]
Yamamoto, Hiroyuki [1 ]
Katoh, Harumi [1 ]
Oka, Naoki [1 ]
Fuku, Yasushi [1 ]
Hosogi, Shingo [1 ]
Hirono, Akitoshi [1 ]
Maruo, Takeshi [1 ]
Tanaka, Hiroyuki [1 ]
Shigemoto, Yoshikazu [1 ]
Hasegawa, Daiji [1 ]
Tasaka, Hiroshi [1 ]
Kusunose, Mana [1 ]
Otsuru, Suguru [1 ]
Okamoto, Yoji [1 ]
Saito, Naoki [1 ]
Tsujimoto, Yuki [1 ]
机构
[1] Kurashiki Cent Hosp, Dept Cardiol, Okayama 7108602, Japan
关键词
Phosphorylcholine-coated stent; Drug-eluting stent; Polymer; SIROLIMUS-ELUTING STENT; NATIVE CORONARY-ARTERY; THROMBOSIS; RESTENOSIS; OUTCOMES; TRIAL; MODEL; RISK;
D O I
10.1536/ihj.52.88
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The efficacy of drug-eluting stents (DES) has been proven, but concerns about late complications after DES have been raised. Polymers that do not increase inflammatory or hypersensitivity reactions which may contribute to late complications are needed for new generation DES. To evaluate the safety and efficacy of phosphorylcholine-polymer coating, we investigated serial clinical and angiographic outcomes after phosphorylcholine-coated stent placement. Seventy-five consecutive patients treated with a BiodivYsio phosphorylcholine-coated stent for de novo lesions at our institute between October 2001 and August 2002 were enrolled. Six-month follow-up angiography was performed in 71 lesions (94.7%), and angiographic restenosis was found in 19 lesions (26.8%). Target lesion revascularization (TLR) was performed in 10 lesions (14.1%). Eighteen-month follow-up angiography was performed in 58(95.1%) of the remaining 61 lesions (excluding TLR lesions), and angiographic restenosis was found in only 3 lesions. The cumulative MACE-free survival rate was 86.3%, 83.6%, and 78.6% at 6-month, 18-month, and 8-year follow-up, respectively. There were no episodes of stent thrombosis. Late loss decreased significantly from 0.74 +/- 0.40 mm (6-months) to 0.51 +/- 0.46 mm (18-months) (P < 0.0001). Phosphorylcholine-coated stent implantation was associated with acceptable clinical and angiographic results. Phosphorylcholine-coating may be an ideal polymer for new generation DESs. (Int Heart J 2011; 52: 88-91)
引用
收藏
页码:88 / 91
页数:4
相关论文
共 50 条
  • [1] Serial angiographic follow-up after stent implantation for chronic total occlusion
    Shizuta, S
    Kimura, T
    Nosaka, H
    Nakagawa, Y
    Tamura, T
    Nobuyoshi, M
    [J]. CIRCULATION, 1998, 98 (17) : 284 - 284
  • [2] Clinical and angiographic follow-up after autologous vein graft-coated stent implantation
    Stefanadis, C
    Toutouzas, K
    Tsiamis, E
    Vlachopoulos, C
    Stratos, C
    Kallikazaros, I
    Vavuranakis, M
    Toutouzas, P
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 351A - 351A
  • [3] Angiographic and clinical follow-up of patients with asymptomatic restenosis after coronary stent implantation
    Nibler, N
    Kastrati, A
    Elezi, S
    Walter, H
    Schühlen, H
    Schömig, A
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 65A - 65A
  • [4] Clinical and angiographic follow-up after single long GFX coronary stent implantation
    Nakagawa, Y
    Yufu, K
    Nakamori, S
    Kimura, T
    Yokoi, H
    Tamura, T
    Hamasaki, N
    Nosaka, H
    Nobuyoshi, M
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2000, 50 (01) : 40 - 47
  • [5] Clinical experience with a new biocompatible phosphorylcholine-coated coronary stent
    Zheng, H
    Barragan, P
    Corcos, T
    Siméoni, JB
    Favereau, X
    Roquebert, PO
    Guérin, Y
    Sainsous, J
    [J]. JOURNAL OF INVASIVE CARDIOLOGY, 1999, 11 (10): : 608 - 614
  • [6] Serial angiographic follow-up over tree years after single Palmaz-Schatz stent implantation
    Jost, S
    Nolte, CWT
    Sturm, M
    Hausmann, D
    [J]. PERFUSION, 1998, 11 (10): : 429 - +
  • [7] SERIAL ANGIOGRAPHIC FOLLOW-UP AFTER PALMAZ-SCHATZ STENT IMPLANTATION - COMPARISON WITH CONVENTIONAL BALLOON ANGIOPLASTY
    KIMURA, T
    NOSAKA, H
    YOKOI, H
    IWABUCHI, M
    NOBUYOSHI, M
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (07) : 1557 - 1563
  • [8] LATE ANGIOGRAPHIC FOLLOW-UP AFTER PALMAZ-SCHATZ STENT IMPLANTATION
    FOLEY, JB
    WHITE, J
    TEEFY, P
    ALMOND, DG
    BROWN, RIG
    PENN, IM
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1995, 76 (01): : 76 - 77
  • [9] Angiographic results and late clinical follow-up after Bard-XT intracoronary stent implantation
    Bueno, RRL
    Guérios, EE
    Tarastchuk, JC
    de Andrade, PMP
    Nercolini, DC
    Pacheco, ALA
    [J]. JOURNAL OF INVASIVE CARDIOLOGY, 1999, 11 (11): : 661 - 666
  • [10] Angiographic Iongterm follow-up after coronary stent implantation in acute myocardial infarction
    Ailaiti Maimaitiming
    Hans-Jrgen Rupprecht
    Flex Post
    Bernd Nowak
    Jrgen Meyer
    [J]. 中国介入心脏病学杂志, 1998, (04) : 156 - 156