Multidetector Computed Tomography Findings of Splenic Artery Aneurysms Associated With Liver Involvement in Wilson's Disease

被引:1
|
作者
Ozdemir, M. [1 ]
Okten, R. S. [1 ]
Kucukay, F. [1 ]
Ereren, M. [2 ]
Ozdemir, F. A. E. [1 ]
Akdogan, M. [1 ]
Kacar, S. [3 ]
Bostanci, E. B. [4 ]
机构
[1] Yuksek Ihtisas Training & Educ Hosp, Radiol, Ankara, Turkey
[2] Umut Hosp, Radiol, Ordu, Turkey
[3] Yuksek Ihtisas Training & Educ Hosp, Gastroenterol, Ankara, Turkey
[4] Yuksek Ihtisas Training & Educ Hosp, Gastrointestinal Surg, Ankara, Turkey
关键词
PORTAL-HYPERTENSION; TRANSPLANT PATIENTS; MANAGEMENT; EXPERIENCE; CIRRHOSIS;
D O I
10.1016/j.transproceed.2017.04.025
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Purpose. The purposed of this study was to examine the incidence and multidetector computed tomography (MDCT) findings of splenic artery aneurysms (SAAs) in patients with liver involvement related to Wilson's disease. Methods. Eighteen patients with clinically and/or pathologically proven Wilson's disease underwent triphasic MDCT. Arterial, portal, and equilibrium phase images were obtained. The analysis of the CT features included the presence and characteristics of the SAA, splenic artery (SA) diameter, the presence and size of the portosystemic collateral vessels, and spleen volume. Results. SAAs were detected in 11 patients (61.1%). Eight (72.7%) patients had multiple aneurysms. In 6 (54.5%) patients, the SAAs were located in the distal third of the SA and the intraparenchymal part of the SA. In 3 (27.3%) patients, the SAAs were located only in the distal third of the SA. In 1 (9.1%) patient, the aneurysms were located in the intermediate, distal third, and intraparenchymal part of the SA; in another (9.1%) patient, the aneurysms were located only in the intraparenchymal part of the SA. There were significant differences between the patients with SAA and those without SAA with respect to SA diameter, portosystemic collateral vessel diameter, and spleen volume (P =.007, P <.001, and P =.006, respectively). Conclusions. The incidence of SAAs seems to be higher in patients with liver involvement related to Wilson's disease compared with patients with other causes of cirrhosis and portal hypertension. Large portosystemic collaterals, increased SA diameter, and spleen volume were significant factors for the presence of SAAs.
引用
收藏
页码:1806 / 1809
页数:4
相关论文
共 50 条
  • [1] Multidetector computed tomographic angiography findings of splenic artery steal syndrome in liver transplantation
    Kirbas, I.
    Ulu, E. M. K.
    Ozturk, A.
    Coskun, M.
    Harman, A.
    Ogus, E.
    Haberal, M.
    TRANSPLANTATION PROCEEDINGS, 2007, 39 (04) : 1178 - 1180
  • [2] Multidetector CT findings of splenic artery aneurysm in children with chronic liver disease
    Ulu, Esra Meltem Kayahan
    Kirbas, Ismail
    Emiroglu, Feride Kural
    Cakir, Banu
    Harman, Ali
    Bakar, Coskun
    Coskun, Mehmet
    PEDIATRIC RADIOLOGY, 2008, 38 (10) : 1095 - 1098
  • [3] Multidetector CT findings of splenic artery aneurysm in children with chronic liver disease
    Esra Meltem Kayahan Ulu
    Ismail Kirbas
    Feride Kural Emiroglu
    Banu Cakir
    Ali Harman
    Coskun Bakar
    Mehmet Coskun
    Pediatric Radiology, 2008, 38 : 1095 - 1098
  • [4] Coronary artery aneurysms as seen on multidetector computed Tomography angiography
    Roy, Sion K.
    Kadakia, Jigar
    Shittu, Adekunle
    Budoff, Matthew J.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2011, 78 (07) : 1127 - 1132
  • [5] Imaging findings of liver involvement of Wilson's disease
    Akhan, Okan
    Akpinar, Erhan
    Karcaaltincaba, Musturay
    Haliloglu, Mithat
    Akata, Deniz
    Karaosmanoglu, Ali Devrim
    Omen, Mustafa
    EUROPEAN JOURNAL OF RADIOLOGY, 2009, 69 (01) : 147 - 155
  • [6] Pulmonary involvement in rheumatoid arthritis: multidetector computed tomography findings
    Yuksekkaya, Ruken
    Celikyay, Fatih
    Yilmaz, Ayse
    Arslan, Sule
    Inanir, Ahmet
    Inonu, Handan
    Deniz, Caglar
    ACTA RADIOLOGICA, 2013, 54 (10) : 1138 - 1149
  • [7] Imaging of Complications of Liver Transplantation: Multidetector Computed Tomography Findings
    Bismpa, K.
    Zlika, S.
    Fouzas, I.
    Imvrios, G.
    Papanikolaou, V.
    Petridis, A.
    TRANSPLANTATION PROCEEDINGS, 2012, 44 (09) : 2751 - 2753
  • [8] Acquired peripheral pulmonary artery aneurysms: morphological spectrum of disease and multidetector computed tomography angiography findings—cases series and literature review
    Tullio Valente
    Ahmad Abu-Omar
    Giacomo Sica
    Alfredo Clemente
    Massimo Muto
    Giorgio Bocchini
    Salvatore Cappabianca
    Gaetano Rea
    La radiologia medica, 2018, 123 : 664 - 675
  • [9] The multidetector computed tomography angiography (MDCTA) in the diagnosis of splenic artery aneurysm and pseudoaneurysm
    Saba, Luca
    Anzidei, Michele
    Lucatelli, Pierleone
    Mallarini, Giorgio
    ACTA RADIOLOGICA, 2011, 52 (05) : 488 - 498
  • [10] COMPUTED-TOMOGRAPHY OF THE LIVER IN WILSON DISEASE
    DIXON, AK
    WALSHE, JM
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1984, 8 (01) : 46 - 49