On cross-flow fan similarity: Effects of casing shape

被引:28
|
作者
Lazzarotto, L
Lazzaretto, A
Martegani, AD
Macor, A
机构
[1] Univ Padua, Dept Mech Engn, I-35131 Padua, Italy
[2] Univ Padua, Dept Management & Engn, I-36100 Vicenza, Italy
关键词
D O I
10.1115/1.1379033
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The limited number of experimental investigations on similarity operation in the literature is not sufficient to state the validity of similarity laws for cross-flow fans. This is also due to the operating conditions occurring in practical applications, where the values of impeller size and rotational speed generally result in low Reynolds numbers and, then, it? a non-negligible influence of viscous forces on performance. The analysis is further complicated by the high influence of the casing shape on performance, which can lead to induced effects on similarity operation. An experimental test program is presented in this paper, aimed at understanding the influence of Reynolds number on performance for different casing shapes. Five impellers having similar shape and different dimensions were tested, each one matched with five casings at different rotational speed. The results show that similarity laws can be applied with good approximation above critical blade Reynolds numbers of around 4000 to 15,000, depending on the geometrical characteristics of the casing. The strong scale effect, shown by some authors in the literature, is not observed in these tests.
引用
收藏
页码:523 / 531
页数:9
相关论文
共 50 条
  • [1] UNSTEADY FLOW ANALYSIS IN A CROSS-FLOW FAN WITH A CASING
    Chen Cichang(Jiangsu University of Science and Technology)
    [J]. Chinese Journal of Mechanical Engineering, 1995, (03) : 228 - 237+243
  • [2] CROSS-FLOW FAN
    TRAMPOSC.H
    [J]. MECHANICAL ENGINEERING, 1965, 87 (02): : 70 - &
  • [3] Internal flow and performance of cross-flow fan
    Fukutomi, Junichiro
    Nakase, Yoshiyuki
    Izawa, Shoichiro
    Tamaki, Masashi
    [J]. Nippon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B, 1995, 61 (590): : 3699 - 3705
  • [4] Flow measurements by PIV in a cross-flow fan
    Chiang, SB
    Chiang, HC
    Wang, CC
    [J]. 2ND ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING, PROCEEDINGS: NEW CONTRIBUTION TO ASIAN SUSTAINABLE DEVELOPMENT, 2004, : 577 - 584
  • [5] Noise reduction of a cross-flow fan
    Lee, DS
    Chen, PH
    Miao, JM
    [J]. JOURNAL OF THE CHINESE INSTITUTE OF ENGINEERS, 1997, 20 (03) : 265 - 273
  • [6] Noise reduction of a cross-flow fan
    Industrial Technology Research Inst, Hsinchu, Taiwan
    [J]. J Chin Inst Eng Trans Chin Inst Eng Ser A, 3 (265-273):
  • [7] Prerotation flow and its control in a cross-flow fan
    Fukutomi, Junichiro
    Nakamura, Rei
    Shigemitsu, Torn
    Houki, Yusuke
    [J]. Nihon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B, 2012, 78 (795): : 1919 - 1927
  • [8] SCALE EFFECTS IN CROSS-FLOW FANS - (EFFECTS OF FAN DIMENSIONS ON PERFORMANCE CURVES)
    TANAKA, S
    MURATA, S
    [J]. JSME INTERNATIONAL JOURNAL SERIES B-FLUIDS AND THERMAL ENGINEERING, 1994, 37 (04): : 844 - 852
  • [9] INTERNAL FLOW IN CROSS-FLOW FAN FOR AIR CONDITIONER
    Chen CichangJiangsu University of Science and TechnologyFukano Tohru Hara YoshinoriKyushu University
    [J]. Chinese Journal of Mechanical Engineering, 1995, (02) : 160 - 167
  • [10] Design and Characterization of a Bearingless Cross-Flow Fan
    Bagaric, Ivana
    Steinert, Daniel
    Wassmer, Florian
    Holenstein, Thomas
    Nussbaumer, Thomas
    Kolar, Johann W.
    [J]. 2021 IEEE/ASME INTERNATIONAL CONFERENCE ON ADVANCED INTELLIGENT MECHATRONICS (AIM), 2021, : 1195 - 1200