The influence of the used applicators on organ and target doses for cervical cancer patients treated with HDR brachytherapy

被引:0
|
作者
Pszczolkowska, Beata [1 ]
Bijok, Michal [2 ]
Brzozowska, Beata [1 ]
机构
[1] Univ Warsaw, Fac Phys, Biomed Phys Div, Warsaw, Poland
[2] Maria Sklodowska Curie Natl Res Inst Oncol, Dept Med Phys, Gliwice, Poland
来源
关键词
HDR brachytherapy; fletcher; ring applicator; organ and target doses; INTRACAVITARY BRACHYTHERAPY; TANDEM; RING; RECOMMENDATIONS; RADIOTHERAPY; CARCINOMA; OVOIDS;
D O I
10.2478/pjmpe-2022-0017
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: The aim of this work was to study the influence of the applicators used for cervical cancer patients treated with high dose-rate brachytherapy (HDR-BT) in the Maria Sklodowska-Curie National Research Institute of Oncology in Warsaw, Poland on doses in the tumour volumes and organs at risk. Material and methods: The treatment was carried out using Iridium-192 in 4 fractions (7.5 Gy each) given in weekly intervals. Two types of applicators were used for comparison: fletcher and ring. The standard dose distribution parameters, read from the system Oncentra Brachy (version 4.5, Elekta), for bladder, rectum, and sigmoid (D-2 cc) and tumour (HRCTV D-100, D-98, D-90) were studied. Patients were divided into two groups (240 treatment plans) depending on the type of applicator used and into four groups according to the tumour volumes (HR-CTV < 25 cm(3) or HR-CTV >= 25 cm(3)). The collected data were analysed using the PQStatSoftware (version 1.8.2). Results: The treatment plans prepared with all types of applicators fulfil the dose distribution requirements, however, the dose delivered to the tumour using the ring applicator was found to be the highest. For the bladder and sigmoid the optimal dose distribution was obtained when using the fletcher applicator, while for the rectum the ring applicator gave the smallest dose value. The D-2 cc parameter for sigmoid obtained for fletcher treatment has smaller values in the case of patients with small tumour volume and for this type of applicator was observed a statistically significant difference when compared with the ring. Conclusions: The ring applicator gives the optimal parameters of the dose distribution independently on the tumour volume with respect to the fletcher applicator, which is however more often used in clinical practice.
引用
收藏
页码:139 / 149
页数:11
相关论文
共 50 条
  • [1] Feasibility and Outcomes for Cervical Cancer Patients Treated with Hybrid Brachytherapy Applicators
    Keller, A.
    Rodriguez-Lopez, J.
    Patel, A.
    Kim, H.
    Houser, C.
    Sukumvanich, P.
    Berger, J.
    Boisen, M.
    Edwards, R.
    Taylor, S.
    Courtney-Brooks, M.
    Olawaiye, A.
    Orr, B.
    Beriwal, S.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2021, 158 : S141 - S142
  • [2] Influence of Applicator Dimensions On Doses to Bladder, Rectum and Sigmoid in HDR Brachytherapy for Cervical Cancer
    Dumane, V.
    Rhome, R.
    Yuan, Y.
    Gupta, V.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3447 - 3447
  • [3] Vaginal mucosal doses in the treatment of cervical cancer using HDR brachytherapy
    Keough, W.
    Bleakley, L.
    White, L.
    Zahra, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S932 - S933
  • [4] The variability of applicator position among high dose rate (HDR) intracavitary brachytherapy applications in cervical cancer patients treated with ring & tandem applicators
    Ebruli, C.
    Demiral, A.
    Eyiler, F.
    Cetingoz, R.
    Kinay, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S275 - S275
  • [5] The variability of applicator position among high dose rate (HDR) intracavitary brachytherapy applications in cervical cancer patients treated with ring & tandem applicators
    Ebruli, C.
    Demiral, A.
    Eyiler, F.
    Cetingoz, R.
    Kinay, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S275 - S276
  • [6] Audit of 100 consecutive cervical cancer patients treated with HDR CT guided brachytherapy
    Zahra, M.
    White, L.
    Bleakley, L.
    Keough, W.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S465 - S465
  • [7] Reproducibility of Immobilization Balloons Used Sequentially for Cervical Cancer HDR Brachytherapy
    Goyal, U.
    Pan, J.
    Dougherty, S. T.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : E283 - E283
  • [8] Comparison of LDR and HDR brachytherapy doses for patients with cancer of the cervix
    Wahab, SH
    Grigsby, PW
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (01): : S303 - S303
  • [9] HDR brachytherapy and EBT of cervical cancer
    Cikaric, S
    [J]. BALKAN CONGRESS OF ONCOLOGY, 1996, : 281 - 286
  • [10] Dosimetric Comparison Between Split Ring and Tandem & Ovoid HDR Brachytherapy Applicators in Cervical Cancer Treatment
    Ishaq, O.
    Montgomery, J. R.
    Duckworth, T.
    Hsu, H.
    Schiff, P. B.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S857 - S857