In vivo 3D brain and extremity MRI at 50 mT using a permanent magnet Halbach array

被引:107
|
作者
O'Reilly, Thomas [1 ]
Teeuwisse, Wouter M. [1 ]
de Gans, Danny [2 ]
Koolstra, Kirsten [1 ]
Webb, Andrew G. [1 ,2 ]
机构
[1] Leiden Univ, Med Ctr, Dept Radiol, CJ Gorter Ctr High Field MRI, Albinusdreef 2, NL-2333 ZA Leiden, Netherlands
[2] Delft Univ Technol, Delft, Netherlands
基金
欧盟地平线“2020”;
关键词
gradient design; Halbach array; low-field MRI; permanent magnets; sustainable imaging; OPEN-ACCESS; LOW-COST; RF COIL; FIELD; SYSTEM; GRADIENT; DESIGN; CONSTRUCTION; FREQUENCY; MHZ;
D O I
10.1002/mrm.28396
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To design a low-cost, portable permanent magnet-based MRI system capable of obtaining in vivo MR images within a reasonable scan time. Methods A discretized Halbach permanent magnet array with a clear bore diameter of 27 cm was designed for operation at 50 mT. Custom-built gradient coils, RF coil, gradient amplifiers, and RF amplifier were integrated and tested on both phantoms and in vivo. Results Phantom results showed that the gradient nonlinearity in the y-direction and z-direction was less than 5% over a 15-cm FOV and did not need correcting. For the x-direction, it was significantly greater, but could be partially corrected in postprocessing. Three-dimensional in vivo scans of the brain of a healthy volunteer using a turbo spin-echo sequence were acquired at a spatial resolution of 4 x 4 x 4 mm in a time of about 2 minutes. The T-1-weighted and T-2-weighted scans showed a good degree of tissue contrast. In addition, in vivo scans of the knee of a healthy volunteer were acquired at a spatial resolution of about 3 x 2 x 2 mm within 12 minutes to show the applicability of the system to extremity imaging. Conclusion This work has shown that it is possible to construct a low-field MRI unit with hardware components costing less than 10 000 Euros, which is able to acquire human images in vivo within a reasonable data-acquisition time. The system has a high degree of portability with magnet weight of approximately 75 kg, gradient and RF amplifiers each 15 kg, gradient coils 10 kg, and spectrometer 5 kg.
引用
收藏
页码:495 / 505
页数:11
相关论文
共 50 条
  • [1] 3D Analytical Model of Permanent Magnet and Electromagnetic Hybrid Halbach Array Electrodynamic Suspension System
    Luo, Cheng
    Zhang, Kunlun
    Zhang, Wenlong
    Jing, Yongzhi
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2020, 15 (04) : 1713 - 1721
  • [2] 3D Analytical Model of Permanent Magnet and Electromagnetic Hybrid Halbach Array Electrodynamic Suspension System
    Cheng Luo
    Kunlun Zhang
    Wenlong Zhang
    Yongzhi Jing
    Journal of Electrical Engineering & Technology, 2020, 15 : 1713 - 1721
  • [3] Demagnetization in Permanent Magnet Slotless Generator Using Halbach Array
    Kallaste, Ants
    Kilk, Aleksander
    Belahcen, Anouar
    Vaimann, Toomas
    Janson, Kuno
    PROCEEDINGS OF THE 13TH INTERNATIONAL SCIENTIFIC CONFERENCE ELECTRIC POWER ENGINEERING 2012, VOLS 1 AND 2, 2012, : 1053 - 1057
  • [4] Analytical calculation and parameter analysis of 3D space magnetic field of permanent magnet and electromagnet hybrid Halbach array
    Luo C.
    Zhu K.-F.
    Zhang K.-L.
    Jing Y.-Z.
    Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2021, 25 (07): : 20 - 29
  • [5] Design of Surface Permanent Magnet-Type Vernier Motor using Halbach Array Magnet
    Kataoka, Yasuhiro
    Takayama, Masakazu
    Matsushima, Yoshitarou
    Anazawa, Yoshihisa
    2015 18TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS), 2015, : 177 - 183
  • [6] Iron Loss Calculation and 3-D Thermal Analysis of Halbach Array Permanent Magnet Synchronous Motor
    Sadeghi, Siavash
    Isfahani, Arash Hassanpour
    Sedghisigarchi, Kourosh
    2015 INTERNATIONAL CONFERENCE ON ELECTRICAL SYSTEMS FOR AIRCRAFT, RAILWAY, SHIP PROPULSION AND ROAD VEHICLES (ESARS), 2015,
  • [7] A Sensing System of the Halbach Array Permanent Magnet Spherical Motor Based on 3-D Hall Sensor
    Li, Hongfeng
    Liu, Wenjun
    Li, Bin
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2018, 13 (01) : 352 - 361
  • [8] Development of a small Beta-NMR system using Halbach Array permanent magnet
    Y. Kimura
    M. Mihara
    K. Matsuta
    M. Fukuda
    Y. Otani
    G. Takayama
    T. Izumikawa
    N. Noguchi
    M. Ogose
    M. Sato
    K. Takatsu
    T. Ohtsubo
    H. Takahashi
    S. Momota
    H. Okumura
    T. Moriguchi
    A. Ozawa
    A. Kitagawa
    S. Sato
    Hyperfine Interactions, 2022, 243
  • [9] Development of a small Beta-NMR system using Halbach Array permanent magnet
    Kimura, Y.
    Mihara, M.
    Matsuta, K.
    Fukuda, M.
    Otani, Y.
    Takayama, G.
    Izumikawa, T.
    Noguchi, N.
    Ogose, M.
    Sato, M.
    Takatsu, K.
    Ohtsubo, T.
    Takahashi, H.
    Momota, S.
    Okumura, H.
    Moriguchi, T.
    Ozawa, A.
    Kitagawa, A.
    Sato, S.
    HYPERFINE INTERACTIONS, 2022, 243 (01):
  • [10] Augmented PD Control Method for Permanent Magnet Spherical Actuators with 3D Magnet Array
    Yan, Liang
    Zhu, Bo
    Jiao, Zongxia
    Chen, Chin-Yin
    Chen, I-Ming
    PROCEEDINGS OF THE 2015 10TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, 2015, : 1665 - 1670