An Improved Method for the Estimation and Visualization of Velocity Fields from Gastric High-Resolution Electrical Mapping

被引:43
|
作者
Paskaranandavadivel, Niranchan [1 ]
O'Grady, Gregory [1 ,2 ]
Du, Peng [1 ]
Pullan, Andrew J. [1 ,3 ,4 ,5 ]
Cheng, Leo K. [1 ]
机构
[1] Univ Auckland, Auckland Bioengn Inst, Auckland 1010, New Zealand
[2] Univ Auckland, Dept Surg, Auckland 1010, New Zealand
[3] Univ Auckland, Dept Engn Sci, Auckland 1010, New Zealand
[4] Massey Univ, Riddet Inst, Palmerston North 4442, New Zealand
[5] Vanderbilt Univ, Dept Surg, Nashville, TN 37240 USA
关键词
Dysrhythmia; finite difference (FD); multielectrode; polynomial fitting; slow waves; VECTOR-FIELDS; PROPAGATION; CONDUCTION; MECHANISMS; ORIGIN; MAPS;
D O I
10.1109/TBME.2011.2181845
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
High-resolution (HR) electrical mapping is an important clinical research tool for understanding normal and abnormal gastric electrophysiology. Analyzing velocities of gastric electrical activity in a reliable and accurate manner can provide additional valuable information for quantitatively and qualitatively comparing features across and within subjects, particularly during gastric dysrhythmias. In this study, we compared three methods of estimating velocities from HR recordings to determine which method was the most reliable for use with gastric HR electrical mapping. The three methods were 1) simple finite difference (FD) 2) smoothed finite difference (FDSM), and 3) a polynomial-based method. With synthetic data, the accuracy of the simple FD method resulted in velocity errors almost twice that of the FDSM and the polynomial-based method, in the presence of activation time error up to 0.5 s. With three synthetic cases under various noise types and levels, the FDSM resulted in average speed error of 3.2% and an average angle error of 2.0 degrees and the polynomial-based method had an average speed error of 3.3% and an average angle error of 1.7 degrees. With experimental gastric slow wave recordings performed in pigs, the three methods estimated similar velocities (6.3-7.3 mm/s), but the FDSM method had a lower standard deviation in its velocity estimate than the simple FD and the polynomial-based method, leading it to be the method of choice for velocity estimation in gastric slow wave propagation. An improved method for visualizing velocity fields is also presented.
引用
收藏
页码:882 / 889
页数:8
相关论文
共 50 条
  • [1] Automated detection of gastric slow wave events and estimation of propagation velocity vector fields from serosal high-resolution mapping
    Du, Peng
    Qiao, Wenlian
    O'Grady, Greg
    Egbuji, John U.
    Lammers, Wim
    Cheng, Leo K.
    Pullan, Andrew J.
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 2527 - +
  • [2] Gastric Arrhythmias in Gastroparesis Low- and High-Resolution Mapping of Gastric Electrical Activity
    O'Grady, Gregory
    Abell, Thomas L.
    GASTROENTEROLOGY CLINICS OF NORTH AMERICA, 2015, 44 (01) : 169 - +
  • [3] Trace Mapping: A New Visualization Technique for Analyzing Gastrointestinal High-Resolution Electrical Mapping Data
    Chan, Chih-Hsiang Alexander
    Aghababaie, Zahra
    Paskaranandavadivel, Niranchan
    Cheng, Leo K.
    Avci, Recep
    Angeli, Timothy R.
    42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 5212 - 5215
  • [4] High-resolution electrical mapping of porcine gastric slow-wave propagation from the mucosal surface
    Angeli, T. R.
    Du, P.
    Paskaranandavadivel, N.
    Sathar, S.
    Hall, A.
    Asirvatham, S. J.
    Farrugia, G.
    Windsor, J. A.
    Cheng, L. K.
    O'Grady, G.
    NEUROGASTROENTEROLOGY AND MOTILITY, 2017, 29 (05):
  • [5] Feasibility of High-Resolution Electrical Mapping for Characterizing Conduction Blocks Created by Gastric Ablation
    Aghababaie, Zahra
    Chan, Chih-Hsiang Alexander
    Paskaranandavadivel, Niranchan
    Beyder, Arthur
    Farrugia, Gianrico
    Asirvatham, Samuel
    O'Grady, Gregory
    Cheng, Leo K.
    Angeli, Timothy R.
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 170 - 173
  • [6] Estimation method for sound velocity distribution for high-resolution ultrasonic tomographic imaging
    Abe, Keiichiro
    Arakawa, Mototaka
    Kanai, Hiroshi
    JOURNAL OF MEDICAL ULTRASONICS, 2019, 46 (01) : 27 - 33
  • [7] Estimation method for sound velocity distribution for high-resolution ultrasonic tomographic imaging
    Keiichiro Abe
    Mototaka Arakawa
    Hiroshi Kanai
    Journal of Medical Ultrasonics, 2019, 46 : 27 - 33
  • [8] HIGH-RESOLUTION MAPPING OF GASTROINTESTINAL ELECTRICAL-ACTIVITY
    LAMMERS, W
    SINGH, S
    ALKAIS, A
    ELSHARKAWY, TY
    FASEB JOURNAL, 1992, 6 (04): : A1514 - A1514
  • [9] The high-resolution optical mapping of cardiac electrical activity
    Xu, ZH
    Zhang, ZX
    Wang, J
    Huang, YC
    PHOTONICS AND IMAGING IN BIOLOGY AND MEDICINE, 2003, 5254 : 452 - 456
  • [10] Methods for High-Resolution Electrical Mapping in the Gastrointestinal Tract
    O'Grady, Gregory
    Angeli, Timothy R.
    Paskaranandavadivel, Niranchan
    Erickson, Jonathan C.
    Wells, Cameron, I
    Gharibans, Armen A.
    Cheng, Leo K.
    Du, Peng
    IEEE REVIEWS IN BIOMEDICAL ENGINEERING, 2019, 12 : 287 - 302