Consistency of complex fractionated atrial electrograms during atrial fibrillation

被引:99
|
作者
Lin, Yenn-Jiang [1 ,2 ,3 ]
Tai, Ching-Tai [1 ]
Kao, Tsair [4 ]
Chang, Shih-Lin [1 ]
Wongcharoen, Wanwarang [2 ,3 ]
Lo, Li-Wei [2 ,3 ]
Tuan, Ta-Chuan [2 ,3 ]
Udyavar, Ameya R. [2 ,3 ]
Chen, Yi-Jen [5 ,6 ]
Higa, Satoshi [7 ]
Ueng, Kuo-Chang [8 ]
Chen, Shih-Ann [1 ,2 ,3 ]
机构
[1] Taipei Vet Gen Hosp, Div Cardiol, Dept Med, Taipei, Taiwan
[2] Natl Yang Ming Univ, Inst Clin Med, Taipei 112, Taiwan
[3] Natl Yang Ming Univ, Cardiovasc Res Ctr, Taipei 112, Taiwan
[4] Natl Yang Ming Univ, Inst Biomed Engn, Taipei 112, Taiwan
[5] Wang Fang Hosp, Taipei, Taiwan
[6] Taipei Med Univ, Taipei, Taiwan
[7] Univ Ryukyus, Fac Med, Dept Internal Med 2, Okinawa, Japan
[8] Chung Shan Med Univ, Taichung, Taiwan
关键词
atrial fibrillation; electrogram; frequency analysis; left atrium; mapping;
D O I
10.1016/j.hrthm.2007.12.009
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Temporal variation in complex fractionated atrial etectrograms (CFAEs) exists during atria[ fibrillation (AF). OBJECTIVE This study sought to quantify the variation in CFAEs using a fractionation interval (FI) algorithm and to define the shortest optimal recording duration required to consistently characterize the magnitude of the fractionation. METHODS Twenty-seven patients undergoing AF mapping in the Left atrium were studied. The FI and frequency analysis were performed at each mapped site for recording durations of I to 8 seconds. The magnitude of the fractionation was quantified by the FI algorithm, which calculated the mean interval between multiple, discrete deflections during AF. The results from each duration were statistically compared with the maximal-duration recording, as a standard. The FI values were compared with the dominant frequency values obtained from the associated frequency spectra. RESULTS The FIs obtained from recording durations between 5 and 8 seconds had a smaller variation in the FI (P < .05) and, for those sites with a FI < 50 ms, the fractionation was typically continuous. The fast-Fourier Transform spectra obtained from the CFAE sites with recording durations of > 5 seconds harbored higher dominant frequency values than those with shorter recording durations (8.1 +/- 2.5 Hz vs. 6.8 +/- 0.98 Hz, P <.05). The CFAE sites with continuous fractionation were Located within the pulmonary veins and their ostia in 77% of patients with paroxysmal AF, and in only 29% of patients with nonparoxysmal AF (P <.05). CONCLUSION The assessment of fractionated electrograms requires a recording duration of 5 seconds at each site to obtain a consistent fractionation. Sites with the shortest FIs consistently identified sites with the fastest electrograrn activity throughout the entire left atrium and pulmonary veins.
引用
收藏
页码:406 / 412
页数:7
相关论文
共 50 条
  • [1] Reproducibility of complex fractionated atrial electrograms during atrial fibrillation
    Gwechenberger, M.
    Gleiss, A.
    Richter, B.
    Goessinger, H.
    [J]. EUROPEAN HEART JOURNAL, 2008, 29 : 546 - 546
  • [2] Different properties of complex fractionated atrial electrograms during atrial fibrillation
    Lei, Sen
    Fang, Pi-hua
    Liu, Jun
    Hou, Yu
    [J]. JOURNAL OF CARDIOVASCULAR MEDICINE, 2012, 13 (03) : 175 - 180
  • [3] Complex Fractionated Atrial Electrograms Is This the Beast to Tame in Atrial Fibrillation?
    Berenfeld, Omer
    Jalife, Jose
    [J]. CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2011, 4 (04): : 426 - 428
  • [4] Fractionated Electrograms in Atrial Fibrillation
    Katritsis, Demosthenes G.
    Ellenbogen, Kenneth A.
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2008, 19 (12) : 58 - 58
  • [5] Electrophysiologic Characteristics of Complex Fractionated Atrial Electrograms in Patients with Atrial Fibrillation
    Park, Jae H.
    Pak, Hui-Nam
    Kim, Sook K.
    Jang, Jin K.
    Choi, Jong I.
    Lim, Hong E.
    Hwang, Chun
    Kim, Young-Hoon
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2009, 20 (03) : 266 - 272
  • [6] Complex Fractionated Atrial Electrograms A Worthwhile Target for Ablation of Atrial Fibrillation?
    Latchamsetty, Rakesh
    Morady, Fred
    [J]. CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2011, 4 (02): : 117 - 118
  • [7] Pitfalls in the definition of complex fractionated atrial electrograms for atrial fibrillation studies
    Almeida, Tiago P.
    Li, Xin
    Soriano, Diogo C.
    Schlindwein, Fernando S.
    Ng, G. Andre
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2020, 31 (01) : 373 - 374
  • [8] Assessing the Stability of Complex Fractionated Atrial Electrograms for the Characterization of Atrial Substrate in Atrial Fibrillation
    Finotti, Emanuela
    Ciaccio, Edward J.
    Garan, Hasan
    Hornero, Fernando
    Alcaraz, Raul
    Rieta, Jose J.
    [J]. 2020 INTERNATIONAL CONFERENCE ON E-HEALTH AND BIOENGINEERING (EHB), 2020,
  • [9] Temporal stability of complex fractionated atrial electrograms in human left atrium during atrial fibrillation
    Scherr, Daniel
    Dalai, Darshan
    Cheema, Aamir
    Nazarian, Saman
    Almasry, Ibrahim
    Bilchick, Kenneth
    Cheng, Alan
    Henrikson, Charles A.
    Spragg, David
    Marine, Joseph E.
    Berger, Ronald D.
    Calkins, Hugh
    Dong, Jun
    [J]. CIRCULATION, 2007, 116 (16) : 392 - 392
  • [10] Relationship of complex fractionated atrial electrograms during atrial fibrillation to the location of cardiac autonomic ganglionated plexi in patients with atrial fibrillation
    Nakagawa, H
    Jackman, WM
    Scherlag, BJ
    Yokoyama, K
    Wu, R
    Oza, SA
    Shukla, H
    Beckman, KJ
    Po, SS
    Lockwood, D
    Herring, L
    Lazzara, R
    [J]. CIRCULATION, 2005, 112 (17) : U810 - U811