Portable global positioning units to complement accelerometry-based physical activity monitors

被引:163
|
作者
Rodríguez, DA
Brown, AL
Troped, PJ
机构
[1] Univ N Carolina, Dept City & Reg Planning, Chapel Hill, NC 27599 USA
[2] Harvard Univ, Sch Publ Hlth, Dept Soc Human Dev & Hlth, Boston, MA 02115 USA
来源
关键词
physical activity; global positioning system; accelerometer; built environment; geographical information systems;
D O I
10.1249/01.mss.0000185297.72328.ce
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Purpose: This study examines the usefulness of complementing accelerometry-based physical activity measurement with spatial data from portable global positioning system (GPS) units to determine where physical activity occurs. Methods: First, using the geographic distribution of data points and Bland-Altman plots, we examined GPS units' validity and interunit reliability by measuring the distance to a geodetic point. We also assessed interunit reliability by comparing GPS data collected in three built environment contexts. Second, we conducted a pilot study in which 35 participants wore GPS units and accelerometers in free-living conditions for 3 d. Moderate and vigorous physical activity (MVPA) bouts were matched to GPS data. We classified each bout as occurring inside or outside the participant's home neighborhood. Using unpaired t-tests and Fisher's exact tests, we compared neighborhood attributes for participants having the majority of MVPA bouts within their home neighborhood, relative to those with most bouts away from their home neighborhood. Results: Average distance from each unit to the geodetic point was 3.02 m (SD 2.51). Average bias among units using Bland-Altman plots was 0.90 m, ranging from -0.22 to 1.86 m, within the limits of agreement. For interunit reliability in the built environment contexts, the mean distance difference among units ranged between 10.7 m (SD 11.9) and 20.1 m (SD 21.8). For the pilot study involving participants, GPS data were available for 59.3% of all bouts (67% of MVPA time), of which 46% were in the participants' neighborhood. Participants obtaining most of their MVPA in their neighborhoods tend to live in areas with higher population density, housing unit density, street connectivity, and more public parks. Conclusion: Data recorded by portable GPS units is sufficiently precise to track participants' movements. Successful matching of activity monitor and locational data suggests GPS is a promising tool for complementing accelerometry-based physical activity measures. Our pilot analysis shows evidence that the relationship between environment and activity can be clarified by examining where physical activity occurs.
引用
收藏
页码:S572 / S581
页数:10
相关论文
共 50 条
  • [1] A comparative evaluation of three accelerometry-based physical activity monitors
    Welk, GJ
    Blair, SN
    Wood, K
    Jones, S
    Thompson, RW
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2000, 32 (09): : S489 - S497
  • [2] Reliability of accelerometry-based activity monitors: A generalizability study
    Welk, GJ
    Schaben, JA
    Morrow, JR
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2004, 36 (09): : 1637 - 1645
  • [3] Protocols for Evaluating Equivalency of Accelerometry-Based Activity Monitors
    Welk, Gregory J.
    McClain, James
    Ainsworth, Barbara E.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2012, 44 : S39 - S49
  • [4] The technology of accelerometry-based activity monitors: Current and future
    Chen, KY
    Bassett, DR
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2005, 37 (11): : S490 - S500
  • [5] Comparability of Measured Acceleration from Accelerometry-Based Activity Monitors
    Rowlands, Alex V.
    Fraysse, Francois
    Catt, Mike
    Stiles, Victoria H.
    Stanley, Rebecca M.
    Eston, Roger G.
    Olds, Tim S.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2015, 47 (01): : 201 - 210
  • [6] Principles of design and analyses for the calibration of accelerometry-based activity monitors
    Welk, GJ
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2005, 37 (11): : S501 - S511
  • [7] Can Accelerometry-Based Physical Activity Monitors Accurately Estimate Exercise Intensity and Running Economy in Athletes?
    Fleming, Joshua J.
    Smoliga, James M.
    Fradkin, Andrea J.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2013, 45 (05): : 164 - 164
  • [8] Accelerometry-Based Activity Spectrum in Persons With Chronic Physical Conditions
    van den Berg-Emons, Rita J.
    Bussmann, Johannes B.
    Stam, Henk J.
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2010, 91 (12): : 1856 - 1861
  • [9] Predicting Energy Expenditure for Ballroom Dancing With Accelerometry-Based Activity Monitors in Experienced Dancers
    Heil, Daniel P.
    Boehming, Katie
    Juergens, Cheryl
    Ludlow, Sarah
    Tambasco, Anna
    Lankford, Eli
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2016, 48 (05): : 845 - 845
  • [10] An Accelerometry-Based Approach to Assess Loading Intensity of Physical Activity on Bone
    Kelley, Sarah
    Hopkinson, Georgina
    Strike, Siobhan
    Luo, Jin
    Lee, Raymond
    RESEARCH QUARTERLY FOR EXERCISE AND SPORT, 2014, 85 (02) : 245 - 250