Calculating Parameters of Pinhole in Collimation System of Albedo Computed Tomography of Steel Products

被引:1
|
作者
Zhuravskii, E. E. [1 ]
Kapranov, B. I. [1 ]
Belkin, D. S. [1 ]
Chakhlov, S. V. [1 ]
Shtein, A. M. [1 ]
机构
[1] Tomsk Polytech Univ, Tomsk 634050, Russia
关键词
Compton tomography; collimation system; pinhole; nondestructive testing; radiation testing; flaw detection; instrument making;
D O I
10.1134/S1061830920020102
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
We examine specific features of the collimation system of a tomograph for testing steel products based on Compton backscattering. The device is described and the parameters of the primary pinhole collimator of the collimation system are calculated. The device allows reliable scanning of a steel test object by simply displacing the pinhole perpendicular to the X-ray axis from the tube anode within 50 mm with a focal length of 163 mm.
引用
收藏
页码:171 / 178
页数:8
相关论文
共 24 条
  • [1] Calculating Parameters of Pinhole in Collimation System of Albedo Computed Tomography of Steel Products
    E. E. Zhuravskii
    B. I. Kapranov
    D. S. Belkin
    S. V. Chakhlov
    A. M. Shtein
    Russian Journal of Nondestructive Testing, 2020, 56 : 171 - 178
  • [2] Analysis of the Aperture Function of the Scattering Volume of the Collimation System of the Scattering Computed Tomography of Steel Products with a Ring Detector
    E. E. Zhuravskiy
    D. S. Belkin
    B. I. Kapranov
    S. V. Chakhlov
    Russian Journal of Nondestructive Testing, 2020, 56 : 506 - 515
  • [3] Analysis of the Aperture Function of the Scattering Volume of the Collimation System of the Scattering Computed Tomography of Steel Products with a Ring Detector
    Zhuravskiy, E. E.
    Belkin, D. S.
    Kapranov, B. I.
    Chakhlov, S. V.
    RUSSIAN JOURNAL OF NONDESTRUCTIVE TESTING, 2020, 56 (06) : 506 - 515
  • [4] Calculating the Mounting Parameters for Taylor Spatial Frame Correction Using Computed Tomography
    Kucukkaya, Metin
    Karakoyun, Ozgur
    Armagan, Raffi
    Kuzgun, Unal
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2011, 25 (07) : 449 - 452
  • [5] Full-field fan-beam x-ray fluorescence computed tomography system design with linear-array detectors and pinhole collimation: a rapid Monte Carlo study
    Zhang, Siyuan
    Li, Liang
    Li, Ruizhe
    Chen, Zhiqiang
    OPTICAL ENGINEERING, 2017, 56 (11)
  • [6] Beaming hardening correction algorithm based on polychromatic system parameters in computed tomography
    Sun, Shaohua
    Gao, Wenhuan
    Zhang, Li
    Chen, Zhiqiang
    Qinghua Daxue Xuebao/Journal of Tsinghua University, 2002, 42 (12): : 1579 - 1582
  • [7] Features of morphometric parameters of vessels in the human portal venous system identified by multislice computed tomography
    Russkikh, A. N.
    Shabokha, A. D.
    Tyumentsev, N., V
    Derevtsova, S. N.
    BYULLETEN SIBIRSKOY MEDITSINY, 2021, 20 (04): : 49 - 55
  • [8] Off-Axis Imaging in Keel-Edge Pinhole Single Photon Emission Computed Tomography System Based on Monte Carlo Simulation
    李素莹
    谢肇恒
    黄智宇
    杨昆
    徐白萱
    任秋实
    Chinese Physics Letters, 2016, (04) : 159 - 162
  • [9] Off-Axis Imaging in Keel-Edge Pinhole Single Photon Emission Computed Tomography System Based on Monte Carlo Simulation
    李素莹
    谢肇恒
    黄智宇
    杨昆
    徐白萱
    任秋实
    Chinese Physics Letters, 2016, 33 (04) : 159 - 162
  • [10] Off-Axis Imaging in Keel-Edge Pinhole Single Photon Emission Computed Tomography System Based on Monte Carlo Simulation
    Li, Su-Ying
    Xie, Zhao-Heng
    Huang, Zhi-Yu
    Yang, Kun
    Xu, Bai-Xuan
    Ren, Qiu-Shi
    CHINESE PHYSICS LETTERS, 2016, 33 (04)