CT of pediatric vascular stents used to treat congenital heart disease

被引:23
|
作者
Eichhorn, Joachim G. [1 ,2 ]
Jourdan, Claudia [2 ,3 ]
Hill, Sharon L. [4 ]
Raman, Subha V. [5 ]
Cheatham, John P. [4 ]
Long, Frederick R. [6 ]
机构
[1] Univ Heidelberg, Childrens Hosp, Dept Pediat Cardiol, D-69120 Heidelberg, Germany
[2] Ohio State Univ, Coll Med, Dept Radiol, Columbus, OH 43210 USA
[3] Univ Heidelberg, Childrens Hosp, Dept Pediat Radiol, D-6900 Heidelberg, Germany
[4] Columbus Childrens Hosp, Ctr Heart, Columbus, OH USA
[5] Ohio State Univ, Coll Med, Davis Heart & Lung Res Inst, Div Cardiol, Columbus, OH 43210 USA
[6] Columbus Childrens Hosp, Childrens Radiol Inst, Columbus, OH USA
关键词
congenital heart disease; MDCT; pediatrics; phantom; radiation exposure; stents;
D O I
10.2214/AJR.07.3194
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of our study was to assess the visibility of lumen narrowing of pediatric vascular stents using various CT dose parameters in an in vitro model. MATERIALS AND METHODS. Ten steel stents of varying designs and sizes commonly used in the treatment of congenital heart disease were implanted in polyvinyl chloride ( PVC) tubes and three of the 10 stents were partially obstructed with wax by filling 25% ( mild) to 60% ( moderate) of the lumen with contrast material. On a 64-MDCT scanner, the stents were scanned at tube voltages ( kVp) of 80, 100, and 120 and at tube currents (mA) of 40, 80, 120, and 160. CT measurements of inner-stent diameter, strut thickness, and percent lumen (in-stent) stenoses were compared with biplane fluoroscopy of digital angiography. RESULTS. The stent diameter and percent stenosis on all CT images were consistently smaller than measured on digital angiography but were highly correlated (r = 0.97; p < 0.0001) with improvement as stent diameter increased (93% agreement with digital angiography for 4-mm stent, up to 99% for 25-mm stent; p = 0.001). Moderate stenosis could be assessed better than mild stenosis ( 99% vs 91% agreement with digital angiography; p = 0.003). Increasing exposure settings improved CT correlation of all measurements for mA up to 120 and kVp up to 100 (98.1% agreement). Higher settings did not improve accuracy (93.9% for 160 mA at 120 kVp; p = 0.03). CONCLUSION. CT is feasible to assess lumen narrowing of pediatric vascular stents at a wide range of tube settings. The study suggests that it is possible to lower the radiation exposure settings without loss in image quality or accuracy in detecting in-stent stenoses.
引用
收藏
页码:1241 / 1246
页数:6
相关论文
共 50 条
  • [1] Intravascular and intracardiac stents used in congenital heart disease
    Okubo, M
    Benson, LN
    CURRENT OPINION IN CARDIOLOGY, 2001, 16 (02) : 84 - 91
  • [2] Usefulness of Multidetector CT Imaging to Assess Vascular Stents in Children With Congenital Heart Disease: An In Vivo and In Vitro Study
    Eichhorn, Joachim G.
    Long, Frederick R.
    Jourdan, Claudia
    Heverhagen, Johannes T.
    Hilli, Sharon L.
    Raman, Subha V.
    Cheatham, John P.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2008, 72 (04) : 544 - 551
  • [3] Pulmonary vascular disease as a complication of pediatric congenital heart diseases
    Wacker, Julie
    Joye, Raphael
    Genecand, Leon
    Lador, Frederic
    Beghetti, Maurice
    TRANSLATIONAL PEDIATRICS, 2023, 12 (05) : 1041 - 1052
  • [4] Tailoring stents to fit the anatomy of unique vascular stenoses in congenital heart disease
    Sullivan, Patrick M.
    Liou, Aimee
    Takao, Cheryl
    Justino, Henri
    Petit, Christopher J.
    Salazar, Jorge D.
    Ing, Frank F.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2017, 90 (06) : 963 - 971
  • [5] Endovascular stents in congenital heart disease
    Benson, LN
    Nykanen, D
    Freedom, RM
    PROGRESS IN CARDIOVASCULAR DISEASES, 1996, 39 (02) : 165 - 186
  • [6] SHOULD METALLIC VASCULAR STENTS BE USED TO TREAT CEREBROVASCULAR OCCLUSIVE DISEASES
    BECKER, GJ
    RADIOLOGY, 1994, 191 (02) : 309 - 312
  • [7] The Use and Outcomes of Small, Medium and Large Premounted Stents in Pediatric and Congenital Heart Disease
    Brian A. Boe
    Jeffrey D. Zampi
    Kurt R. Schumacher
    Sunkyung Yu
    Aimee K. Armstrong
    Pediatric Cardiology, 2016, 37 : 1525 - 1533
  • [8] The Use and Outcomes of Small, Medium and Large Premounted Stents in Pediatric and Congenital Heart Disease
    Boe, Brian A.
    Zampi, Jeffrey D.
    Schumacher, Kurt R.
    Yu, Sunkyung
    Armstrong, Aimee K.
    PEDIATRIC CARDIOLOGY, 2016, 37 (08) : 1525 - 1533
  • [9] REVEAL Registry: Pediatric IPAH Versus Pediatric Pulmonary Vascular Disease Associated with Congenital Heart Disease
    Barst, R. J.
    Ivy, D.
    Badesch, D. B.
    Benza, R. L.
    Elliott, C. G.
    Farber, H. W.
    Forst, A. E.
    Krichman, A.
    Liou, T. G.
    Raskob, G. E.
    Wason, P.
    Feldkircher, K.
    Foreman, A. J.
    McGoon, M. D.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2009, 28 (02): : S203 - S203
  • [10] PEDIATRIC AND CONGENITAL HEART DISEASE
    Zampi, Jeffrey D.
    Hirsch-Romano, Jennifer C.
    Goldstein, Bryan H.
    Shaya, Justin A.
    Armstrong, Aimee K.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2014, 83 (05) : 753 - 761