Feasibility and Accuracy of Thoracolumbar Minimally Invasive Pedicle Screw Placement With Augmented Reality Navigation Technology

被引:91
|
作者
Elmi-Terander, Adrian [1 ]
Nachabe, Rami [2 ]
Skulason, Halldor [1 ]
Pedersen, Kyrre [1 ]
Soderman, Michael [1 ]
Racadio, John [2 ]
Babic, Drazenko [3 ]
Gerdhem, Paul [4 ]
Edstrom, Erik [1 ]
机构
[1] Karolinska Hosp, Dept Neuroradiol, Stockholm, Sweden
[2] Philips Healthcare, Image Guided Therapy Syst, Best, Netherlands
[3] Cincinnati Childrens Hosp, Dept Radiol, Cincinnati, OH USA
[4] Karolinska Hosp, Dept Orthoped, Stockholm, Sweden
基金
欧盟地平线“2020”;
关键词
accuracy; augmented reality; hybrid operating room; integrated navigation; minimally invasive pedicle screw; occupational radiation dose; SURGICAL NAVIGATION; RADIATION-EXPOSURE; LUMBAR SPINE; SURGERY; FUSION;
D O I
10.1097/BRS.0000000000002502
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Cadaveric laboratory study. Objective. To assess the feasibility and accuracy of minimally invasive thoracolumbar pedicle screw placement using augmented reality (AR) surgical navigation. Summary of Background Data. Minimally invasive spine (MIS) surgery has increasingly become the method of choice for a wide variety of spine pathologies. Navigation technology based on AR has been shown to be feasible, accurate, and safe in open procedures. AR technology may also be used for MIS surgery. Methods. The AR surgical navigation was installed in a hybrid operating room (OR). The hybrid OR includes a surgical table, a motorized flat detector C-arm with intraoperative 2D/3D imaging capabilities, integrated optical cameras for AR navigation, and patient motion tracking using optical markers on the skin. Navigation and screw placement was without any x-ray guidance. Two neurosurgeons placed 66 Jamshidi needles (two cadavers) and 18 cannulated pedicle screws (one cadaver) in the thoracolumbar spine. Technical accuracy was evaluated by measuring the distance between the tip of the actual needle position and the corresponding planned path as well as the angles between the needle and the desired path. Time needed for navigation along the virtual planned path was measured. An independent reviewer assessed the postoperative scans for the pedicle screws' clinical accuracy. Results. Navigation time per insertion was 90 +/- 53 seconds with an accuracy of 2.2 +/- 1.3 mm. Accuracy was not dependent on operator. There was no correlation between navigation time and accuracy. The mean error angle between the Jamshidi needles and planned paths was 0.98 +/- 0.88. No screw was misplaced outside the pedicle. Two screws breached 2 to 4mm yielding an overall accuracy of 89% (16/18). Conclusion. MIS screw placement directed by AR with intraoperative 3D imaging in a hybrid OR is accurate and efficient, without any fluoroscopy or x-ray imaging during the procedure.
引用
收藏
页码:1018 / 1023
页数:6
相关论文
共 50 条
  • [1] Feasibility and Accuracy of Thoracolumbar Pedicle Screw Placement Using an Augmented Reality Head Mounted Device
    Frisk, Henrik
    Lindqvist, Eliza
    Persson, Oscar
    Weinzierl, Juliane
    Bruetzel, Linda K.
    Cewe, Paulina
    Burstrom, Gustav
    Edstrom, Erik
    Elmi-Terander, Adrian
    SENSORS, 2022, 22 (02)
  • [2] OpEyes-Augmented Reality Surgical Navigation and Advanced Minimally Invasive Pedicle Screw Navigation
    Parr, Ryan
    Felix, Brent
    Cvetko, Steve
    Gibby, Wendell
    NEUROSURGERY, 2022, 68 : 32 - 33
  • [3] Minimally Invasive Transforaminal Lumbar Interbody Fusion Using Augmented Reality Surgical Navigation for Percutaneous Pedicle Screw Placement
    Charles, Yann P.
    Cazzato, Roberto L.
    Nachabe, Rami
    Chatterjea, Anindita
    Steib, Jean-Paul
    Gangi, Afshin
    CLINICAL SPINE SURGERY, 2021, 34 (07): : E415 - E424
  • [4] Implications of navigation in thoracolumbar pedicle screw placement on screw accuracy and screw diameter/pedicle width ratio
    Mandelka, Eric
    Gierse, Jula
    Zimmermann, Felix
    Gruetzner, Paul A.
    Franke, Jochen
    Vetter, Sven Y.
    BRAIN AND SPINE, 2023, 3
  • [5] Accuracy of augmented reality surgical navigation for minimally invasive pedicle screw insertion in the thoracic and lumbar spine with a new tracking device
    Peh, Simon
    Chatterjea, Anindita
    Pfarr, Julian
    Schaefer, Jost Philipp
    Weuster, Matthias
    Klueter, Tim
    Seekamp, Andreas
    Lippross, Sebastian
    SPINE JOURNAL, 2020, 20 (04): : 629 - 637
  • [6] Augmented Reality Spine Surgery Navigation Increasing Pedicle Screw Insertion Accuracy for Both Open and Minimally Invasive Spine Surgeries
    Felix, Brent
    Kalatar, Seyed Babak
    Moatz, Bradley
    Hofstetter, Christoph
    Karsy, Michael
    Parr, Ryan
    Gibby, Wendell
    SPINE, 2022, 47 (12) : 865 - 872
  • [7] Techniques and accuracy of thoracolumbar pedicle screw placement
    Puvanesarajah, Varun
    Liauw, Jason A.
    Lo, Sheng-fu
    Lina, Ioan A.
    Witham, Timothy F.
    WORLD JOURNAL OF ORTHOPEDICS, 2014, 5 (02): : 112 - 123
  • [8] Cirq® robotic assistance for thoracolumbar pedicle screw placement - feasibility, accuracy, and safety
    Gabrovsky, Nikolay
    Ilkov, Petar
    Laleva, Maria
    BRAIN AND SPINE, 2023, 3
  • [9] How safe is minimally invasive pedicle screw placement for treatment of thoracolumbar spine fractures?
    Timo Michael Heintel
    Stefan Dannigkeit
    Annabel Fenwick
    Martin Cornelius Jordan
    Hendrik Jansen
    Fabian Gilbert
    Rainer Meffert
    European Spine Journal, 2017, 26 : 1515 - 1524
  • [10] How safe is minimally invasive pedicle screw placement for treatment of thoracolumbar spine fractures?
    Heintel, Timo Michael
    Dannigkeit, Stefan
    Fenwick, Annabel
    Jordan, Martin Cornelius
    Jansen, Hendrik
    Gilbert, Fabian
    Meffert, Rainer
    EUROPEAN SPINE JOURNAL, 2017, 26 (05) : 1515 - 1524