Retrofitting Effect on the Dynamic Properties of Model-Arch Dam with and without Reservoir Water Using Ambient-Vibration Test Methods

被引:14
|
作者
Altunisik, Ahmet Can [1 ]
Gunaydin, Murat [2 ]
Sevim, Baris [3 ]
Bayraktar, Alemdar [1 ]
Adanur, Suleyman [1 ]
机构
[1] Karadeniz Tech Univ, Dept Civil Engn, TR-61080 Trabzon, Turkey
[2] Gumushane Univ, Dept Civil Engn, TR-29100 Gumushane, Turkey
[3] Yildiz Tech Univ, Dept Civil Engn, TR-34220 Istanbul, Turkey
关键词
Ambient vibration test; Arch dam-reservoir-foundation model; Carbon fiber reinforced polymer; Dynamic properties; Retrofitting; Structural health monitoring; SEISMIC RESPONSE; IDENTIFICATION; BEHAVIOR;
D O I
10.1061/(ASCE)ST.1943-541X.0001520
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Continuous health monitoring and regular condition assessment is of vital importance for engineering structures in general and especially for arch dams. These structures can be exposed to many different loads such as earthquake, blast, wind, ice, and water pressure, which may cause deterioration and loss of structural integrity. Such development may have severe economic consequence and, more importantly, may present a serious risk to public safety. Therefore, the structural behavior of arch dams must be monitored at regular intervals during their service life, although the overall failure rate of these dams is around 1%. Experimental measurements by ambient vibration test methods are among the most commonly preferred inspection techniques for the evaluation of structural performance and safety. The aim of this research is to examine the retrofitting effect on the dynamic properties of a damaged arch dam model, with and without reservoir water, after retrofitting with high-strength structural repair mortar and carbon fiber reinforced polymer composite material. To this end, an arch dam-reservoir-foundation model was built. In the study, ambient vibration tests were carried out for three test-cases to determine changes in dynamic properties, such as natural frequency, mode shape, and damping ratio before and after retrofitting. The three cases were (1)a severely damaged dam with full reservoir (Case-A), (2)a repaired dam with full reservoir (Case-B), and (3)a strengthened dam with full reservoir (Case-C). In addition, all the measurement tests were repeated with an empty reservoir to extract the effect of water. Data for the ambient vibration tests were gathered from the dam body during vibrations by natural excitations. These excitations were provided through small impacts, and the response signals were measured by sensitivity accelerometers placed at the crest points. To obtain the experimental dynamic properties, the enhanced frequency domain decomposition method in the frequency domain was used. Comparisons of experimentally identified dynamic properties for the damaged and the retrofitted dam showed that the retrofitting application affected the structural behavior of the arch dam considerably. It was very effective in restoring the structure's original dynamic properties.
引用
收藏
页数:13
相关论文
共 13 条
  • [1] Determination of Water Level Effects on the Dynamic Characteristics of a Prototype Arch Dam Model using Ambient Vibration Testing
    Sevim, B.
    Bayraktar, A.
    Altunisik, A. C.
    Adanur, S.
    Akkose, M.
    EXPERIMENTAL TECHNIQUES, 2012, 36 (01) : 72 - 82
  • [2] Determination of water level effects on the dynamic characteristics of a prototype arch dam model using ambient vibration testing
    B. Sevim
    A. Bayraktar
    A. C. Altunişik
    S. Adanur
    M. Akköse
    Experimental Techniques, 2012, 36 : 72 - 82
  • [3] Earthquake Behavior of Berke Arch Dam Using Ambient Vibration Test Results
    Sevim, Baris
    Altunisik, Ahmet Can
    Bayraktar, Alemdar
    JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2012, 26 (06) : 780 - 792
  • [4] Dynamic Characteristics of an Arch Dam Model before and after Strengthening with Consideration of Reservoir Water
    Altunisik, Ahmet Can
    Gunaydin, Murat
    Sevim, Baris
    Bayraktar, Alemdar
    Adanur, Suleyman
    JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2016, 30 (06)
  • [5] Ambient Vibration Tests of an Arch Dam with Different Reservoir Water Levels: Experimental Results and Comparison with Finite Element Modelling
    Calcina, Sergio Vincenzo
    Eltrudis, Laura
    Piroddi, Luca
    Ranieri, Gaetano
    SCIENTIFIC WORLD JOURNAL, 2014,
  • [6] Experimental evaluation of crack effects on the dynamic characteristics of a prototype arch dam using ambient vibration tests
    Sevim, Baris
    Altunisik, Ahmet Can
    Bayraktar, Alemdar
    COMPUTERS AND CONCRETE, 2012, 10 (03): : 277 - 294
  • [7] Obtaining Dynamic Parameters by Using Ambient Vibration Recordings on Model of The Steel Arch Bridge
    Kasimzade, Azer A.
    Tuhta, Sertac
    Gunday, Furkan
    Aydin, Hakan
    PERIODICA POLYTECHNICA-CIVIL ENGINEERING, 2021, 65 (02): : 608 - 618
  • [8] Boundary element model for the analysis of the dynamic response of the Soria arch dam and experimental validation from ambient vibration tests
    Galvan, J. C.
    Padron, L. A.
    Aznarez, J. J.
    Maeso, O.
    ENGINEERING ANALYSIS WITH BOUNDARY ELEMENTS, 2022, 144 : 67 - 80
  • [9] Dam Seepage Monitoring Model Based on Dynamic Effect Weight of Reservoir Water Level
    Huang, Hao
    Chen, Bo
    2012 INTERNATIONAL CONFERENCE ON FUTURE ENERGY, ENVIRONMENT, AND MATERIALS, PT A, 2012, 16 : 159 - 165
  • [10] Dynamic response of a historical armory building using the finite element model validated by the ambient vibration test
    Altunisik, Ahmet Can
    Genc, Ali Fuat
    Gunaydin, Murat
    Okur, Fatih Yesevi
    Karahasan, Olguhan Sevket
    JOURNAL OF VIBRATION AND CONTROL, 2018, 24 (22) : 5472 - 5484