Development of a Fully Automated Graf Standard Plane and Angle Evaluation Method for Infant Hip Ultrasound Scans

被引:13
|
作者
Chen, Tao [1 ]
Zhang, Yuxiao [2 ]
Wang, Bo [2 ]
Wang, Jian [2 ]
Cui, Ligang [3 ]
He, Jingnan [1 ]
Cong, Longfei [2 ]
机构
[1] Peking Univ, Beijing Jishuitan Hosp, Clin Coll 4, Dept Ultrasound, Beijing 100035, Peoples R China
[2] Shenzhen Mindray Biomed Elect Co Ltd, Shenzhen 518057, Peoples R China
[3] Peking Univ Third Hosp, Dept Ultrasound, Beijing 100191, Peoples R China
关键词
developmental dysplasia of the hip (DDH); ultrasound image; standard plane detection; computer-aided diagnosis; deep learning; DYSPLASIA METRICS; DIAGNOSIS; ULTRASONOGRAPHY; CLASSIFICATION; RELIABILITY; ADEQUACY; NETWORK; DISEASE; IMAGES; ALPHA;
D O I
10.3390/diagnostics12061423
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Graf's method is currently the most commonly used ultrasound-based technique for the diagnosis of developmental dysplasia of the hip (DDH). However, the efficiency and accuracy of diagnosis are highly affected by the sonographers' qualification and the time and effort expended, which has a significant intra- and inter-observer variability. Methods: Aiming to minimize the manual intervention in the diagnosis process, we developed a deep learning-based computer-aided framework for the DDH diagnosis, which can perform fully automated standard plane detection and angle measurement for Graf type I and type II hips. The proposed framework is composed of three modules: an anatomical structure detection module, a standard plane scoring module, and an angle measurement module. This framework can be applied to two common clinical scenarios. The first is the static mode, measurement and classification are performed directly based on the given standard plane. The second is the dynamic mode, where a standard plane from ultrasound video is first determined, and measurement and classification are then completed. To the best of our knowledge, our proposed framework is the first CAD method that can automatically perform the entire measurement process of Graf's method. Results: In our experiments, 1051 US images and 289 US videos of Graf type I and type II hips were used to evaluate the performance of the proposed framework. In static mode, the mean absolute error of alpha, beta angles are 1.71 degrees and 2.40 degrees, and the classification accuracy is 94.71%. In dynamic mode, the mean absolute error of alpha, beta angles are 1.97 degrees and 2.53 degrees, the classification accuracy is 89.51%, and the running speed is 31 fps. Conclusions: Experimental results demonstrate that our fully automated framework can accurately perform standard plane detection and angle measurement of an infant's hip at a fast speed, showing great potential for clinical application.
引用
收藏
页数:16
相关论文
共 7 条
  • [1] Deep Learning based Determination of Graf Standart Plane on Hip Ultrasound Scans
    Pelit, Baran
    Abay, Huseyin
    Akkas, Burhan Bilal
    Sezer, Aysun
    32ND IEEE SIGNAL PROCESSING AND COMMUNICATIONS APPLICATIONS CONFERENCE, SIU 2024, 2024,
  • [2] The standard plane of Graf - A "standard sector"? Ultrasound examination of anatomic preparations of infant hips
    Falliner, A
    ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 2001, 139 (02): : 138 - 142
  • [3] A new sign in the standard hip ultrasound image of the Graf method
    Vasilescu, Dan
    Cosma, Dan
    Vasilescu, Dana Elena
    Jid, Carolina Botar
    Gersak, Mirela
    Lenghel, Manuela
    Dudea, Sorin Marian
    MEDICAL ULTRASONOGRAPHY, 2015, 17 (02) : 206 - 210
  • [4] Reproducibility of acquiring ultrasonographic infant hip images by the Graf method after an infant hip ultrasound training course
    Yasuhiro Shirai
    Kenjiro Wakabayashi
    Ikuo Wada
    Hideyuki Goto
    Yoshino Ueki
    Atsushi Tsuchiya
    Yoshiaki Tsuboi
    Myongsu Ha
    Takanobu Otsuka
    Journal of Medical Ultrasonics, 2018, 45 : 583 - 589
  • [5] Reproducibility of acquiring ultrasonographic infant hip images by the Graf method after an infant hip ultrasound training course
    Shirai, Yasuhiro
    Wakabayashi, Kenjiro
    Wada, Ikuo
    Goto, Hideyuki
    Ueki, Yoshino
    Tsuchiya, Atsushi
    Tsuboi, Yoshiaki
    Ha, Myongsu
    Otsuka, Takanobu
    JOURNAL OF MEDICAL ULTRASONICS, 2018, 45 (04) : 583 - 589
  • [6] Morphological Development of the Hip in Normal Infants Under Six Months of Age by the Graf Ultrasound Method
    Liu, Bing
    Hu, Xiaoyun
    Li, Lianyong
    Gao, Shuxi
    FRONTIERS IN PEDIATRICS, 2022, 10
  • [7] Development of a fully automated on-line solid phase extraction and high-performance liquid chromatography with diode array detection method for the pharmacokinetic evaluation of bavachinin: A study on absolute bioavailability and dose proportionality
    Liu, Lei
    Liu, Kang-Ning
    Wen, Ya-Bin
    Zhang, Han-Wen
    Lu, Ya-Xin
    Yin, Zheng
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 893 : 21 - 28