Lifetime measurement of a particular deep crack failure on a flat-type divertor mockup under cyclic high heat flux loading conditions

被引:8
|
作者
Huang, Shenghong [1 ]
Pan, Zhiwei [1 ]
Jiang, Menglai [1 ]
Zhao, Kai [1 ]
Su, Yong [1 ]
机构
[1] Univ Sci & Technol China, Dept Modern Mech, CAS Key Lab Mech Behav & Design Mat, Hefei 230027, Peoples R China
关键词
plasma facing components; digital image correlation; deep cracking; high heat flux; ratcheting damage; TUNGSTEN; BEHAVIOR; FATIGUE; JOINTS; FIELDS;
D O I
10.1088/1741-4326/ac41f7
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
Plasma facing components are key to enduring high heat flux (HHF) loading from high-temperature plasma in nuclear fusion reactors. Understanding their thermal-mechanical behavior and cracking failure mechanisms related to structural designs and fabrication technologies during HHF loading is of great significance for improving their servicing performance and R&D (research and development) levels. In this study, a particular deep cracking failure process on the tungsten layer of a flat-type divertor mockup during 1800 cycles of 10 MW m(-2) HHF loadings is completely monitored and measured with a special improved digital image correlation (DIC) technique. It is found that the DIC measurement under the HHF loading environment is improved successfully to capture fine deformation and strain fields with a spatial resolution less than 0.35 mm so that field strain on a 1 mm thick copper interlayer and deep crack initiation at several microns scale on the tungsten layer are measured out. Based on both full field and local strain and displacement measurements of the target divertor mockup, the thermal mechanical behaviors from deformation to crack initiation and propagation are successfully measured and traced. It is revealed that for the baseline copper interlayer design of a flat-type divertor mockup, the accumulation of plastic strain in the copper interlayer during ratcheting damage induces enough tensile stress on the tungsten layer during HHF cycles, leading to cracking and fracture failures even in its elastic state earlier than the copper LCF lifetime. Current Structural Design Criteria for ITER In-Vessel Components rules fail to cover this kind of ratcheting cracking failure mode in the design stage. New design models or mechanical validation rules to resolve this design blind spot should be established in the future.
引用
收藏
页数:18
相关论文
共 6 条
  • [1] In situ measurements of deformation to fatigue failure on a flat-type divertor mockup under high heat flux loads by 3D digital image correlation
    Pan Z.
    Huang S.
    Jiang M.
    Nuclear Fusion, 2021, 61 (02)
  • [2] Development of continuous V-shaped structure for high heat flux components of flat-type divertor
    Feng, Siqing
    Peng, Xuebing
    Song, Yuntao
    Liu, Peng
    Song, Wei
    Mao, Xin
    Qian, Xinyuan
    Khan, Muhammad Salman
    NUCLEAR MATERIALS AND ENERGY, 2023, 35
  • [3] Degradation of tungsten monoblock divertor under cyclic high heat flux loading
    Nogami, Shuhei
    Toyota, Michitoshi
    Guan, Wenhai
    Hasegawa, Akira
    Ueda, Yoshio
    FUSION ENGINEERING AND DESIGN, 2017, 120 : 49 - 60
  • [4] Improved structural strength and lifetime of monoblock divertor targets by using doped tungsten alloys under cyclic high heat flux loading
    Nogami, S.
    Guan, W. H.
    Hattori, T.
    James, K.
    Hasegawa, A.
    PHYSICA SCRIPTA, 2017, T170
  • [5] Microchannel cooling technique for dissipating high heat flux on W/Cu flat-type mock-up for EAST divertor
    Lu, Mingxiang
    Han, Le
    Zhao, Qi
    Qiu, Juncheng
    Zhou, Jianhong
    Hu, Dinghua
    Mou, Nanyu
    Chen, Xuemei
    PLASMA SCIENCE & TECHNOLOGY, 2022, 24 (09)
  • [6] Microchannel cooling technique for dissipating high heat flux on W/Cu flat-type mock-up for EAST divertor
    鲁铭翔
    韩乐
    赵起
    邱俊城
    周剑宏
    胡定华
    牟南瑜
    陈雪梅
    Plasma Science and Technology, 2022, (09) : 138 - 148