Advanced Morphological 3D Magnetic Resonance Observation of Cartilage Repair Tissue (MOCART) Scoring Using a New Isotropic 3D Proton-Density, Turbo Spin Echo Sequence With Variable Flip Angle Distribution (PD-SPACE) Compared to an Isotropic 3D Steady-State Free Precession Sequence (True-FISP) and Standard 2D Sequences

被引:35
|
作者
Welsch, Goetz H. [1 ,2 ]
Zak, Lukas [3 ]
Mamisch, Tallal C. [4 ]
Paul, Dominik [5 ]
Lauer, Lars [5 ]
Mauerer, Andreas [2 ]
Marlovits, Stefan [3 ]
Trattnig, Siegfried
机构
[1] Med Univ Vienna, Dept Radiol, MR Ctr, High Field MRA 1090, Vienna, Austria
[2] Univ Hosp Erlangen, Dept Trauma Surg, Erlangen, Germany
[3] Med Univ Vienna, Dept Trauma Surg, Ctr Joint & Cartilage, Vienna, Austria
[4] Univ Bern, Dept Orthoped Surg, Bern, Switzerland
[5] Siemens Healthcare, Erlangen, Germany
关键词
PD-SPACE; True-FISP; MOCART; cartilage repair; AUTOLOGOUS CHONDROCYTE IMPLANTATION; ARTICULAR-CARTILAGE; 3.0; TESLA; KNEE; MRI; DEFECTS; TRANSPLANTATION; ABNORMALITIES;
D O I
10.1002/jmri.22399
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate a new isotropic 3D proton-density, turbo-spin-echo sequence with variable flip-angle distribution (PD-SPACE) sequence compared to an isotropic 3D true-fast-imaging with steady-state-precession (True-FISP) sequence and 2D standard MR sequences with regard to the new 3D magnetic resonance observation of cartilage repair tissue (MOCART) score. Materials and Methods: Sixty consecutive MR scans on 37 patients (age: 32.8 +/- 7.9 years) after matrix-associated autologous chondrocyte transplantation (MACT) of the knee were prospectively included. The 3D MOCART score was assessed using the standard 2D sequences and the multiplanar-reconstruction (MPR) of both isotropic sequences. Statistical, Bonferroni-corrected correlation as well as subjective quality analysis were performed. Results: The correlation of the different sequences was significant for the variables defect fill, cartilage interface, bone interface, surface, subchondral lamina, chondral osteophytes, and effusion (Pearson coefficients 0.514-0.865). Especially between the standard sequences and the 3D True-FISP sequence, the variables structure, signal intensity, subchondral bone, and bone marrow edema revealed lower, not significant, correlation values (0.242-0.383). Subjective quality was good for all sequences (P >= 0.05). Artifacts were most often visible on the 3D True-FISP sequence (P < 0.05). Conclusion: Different isotropic sequences can be used for the 3D evaluation of cartilage repair with the benefits of isotropic 3D MRI, MPR, and a significantly reduced scan time, where the 3D PD-SPACE sequence reveals the best results.
引用
收藏
页码:180 / 188
页数:9
相关论文
共 16 条
  • [1] MRI of the lumbar spine: comparison of 3D isotropic turbo spin-echo SPACE sequence versus conventional 2D sequences at 3.0 T
    Lee, Sungwon
    Jee, Won-Hee
    Jung, Joon-Yong
    Lee, So-Yeon
    Ryu, Kyeung-Sik
    Ha, Kee-Yong
    ACTA RADIOLOGICA, 2015, 56 (02) : 174 - 181
  • [2] SLAP tears: diagnosis using 3-T shoulder MR arthrography with the 3D isotropic turbo spin-echo space sequence versus conventional 2D sequences
    Jung, Joon-Yong
    Jee, Won-Hee
    Park, Michael Yong
    Lee, So-Yeon
    Kim, Yang-Soo
    EUROPEAN RADIOLOGY, 2013, 23 (02) : 487 - 495
  • [3] SLAP tears: diagnosis using 3-T shoulder MR arthrography with the 3D isotropic turbo spin-echo space sequence versus conventional 2D sequences
    Joon-Yong Jung
    Won-Hee Jee
    Michael Yong Park
    So-Yeon Lee
    Yang-Soo Kim
    European Radiology, 2013, 23 : 487 - 495
  • [4] Single isotropic 3D fast spin echo sequence compared with conventional 2D sequences for detecting meniscal and cruciate ligament tears in the knee
    El-Liethy, Nevien Ezzat
    Rashwan, Amr Samir
    Kamal, Heba
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2020, 51 (01):
  • [5] Single isotropic 3D fast spin echo sequence compared with conventional 2D sequences for detecting meniscal and cruciate ligament tears in the knee
    Nevien Ezzat El-Liethy
    Amr Samir Rashwan
    Heba Kamal
    Egyptian Journal of Radiology and Nuclear Medicine, 51
  • [6] Supraspinatus tendon tears at 3.0 T shoulder MR arthrography: diagnosis with 3D isotropic turbo spin-echo SPACE sequence versus 2D conventional sequences
    Jung, Joon-Yong
    Jee, Won-Hee
    Park, Michael Y.
    Lee, So-Yeon
    Kim, Yang-Soo
    SKELETAL RADIOLOGY, 2012, 41 (11) : 1401 - 1410
  • [7] Supraspinatus tendon tears at 3.0 T shoulder MR arthrography: diagnosis with 3D isotropic turbo spin-echo SPACE sequence versus 2D conventional sequences
    Joon-Yong Jung
    Won-Hee Jee
    Michael Y. Park
    So-Yeon Lee
    Yang-Soo Kim
    Skeletal Radiology, 2012, 41 : 1401 - 1410
  • [8] Comparing an accelerated 3D fast spin-echo sequence (CS-SPACE) for knee 3-T magnetic resonance imaging with traditional 3D fast spin-echo (SPACE) and routine 2D sequences
    Faysal F. Altahawi
    Kevin J. Blount
    Nicholas P. Morley
    Esther Raithel
    Imran M. Omar
    Skeletal Radiology, 2017, 46 : 7 - 15
  • [9] Comparing an accelerated 3D fast spin-echo sequence (CS-SPACE) for knee 3-T magnetic resonance imaging with traditional 3D fast spin-echo (SPACE) and routine 2D sequences
    Altahawi, Faysal F.
    Blount, Kevin J.
    Morley, Nicholas P.
    Raithel, Esther
    Omar, Imran M.
    SKELETAL RADIOLOGY, 2017, 46 (01) : 7 - 15
  • [10] Rapid fat-suppressed isotropic steady-state free precession imaging using true 3D multiple-half-echo projection reconstruction
    Lu, AM
    Brodsky, E
    Grist, TM
    Block, WF
    MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (03) : 692 - 699